National Repository of Grey Literature 20 records found  1 - 10next  jump to record: Search took 0.00 seconds. 
The expression of the accuracy of the gauge and measurement
Svobodová, Helena ; Koška, Petr (referee) ; Pernikář, Jiří (advisor)
The bachelor thesis deals with the issue of measurement, accuracy of measuring instruments and their expressing. It outlines the legislative basis of metrology in the Czech Republic and interprets the definitions of basic terms used in metrology. These definitions are listed in the new edition of International dictionary of metrology (VIM 3:2007). It specifies and exemplifies measurement errors and presents possibilities of their elimination. Further, it describes a simple way of measurement uncertainty determination. The aim of this thesis is to explain the issue in a way that it is understandable and can be applicable for the common metrology practice.
The theoretical and actual measurement accuracy of TRITOP photogrammetry system
Klus, Patrik ; Mendřický, Radomír (referee) ; Zatočilová, Aneta (advisor)
This diploma thesis examines the impact of selected factors on the measurement accuracy of Tritop photogrammetry system and verifies the validity of theoretical predictive formulas. Primary attention is given to factors that are easily influenced by the inspector - namely number of captured images, shooting distance, number of scale bars and number of coded targets. In addition, experiments dealing with the measurement automation and the use of external color filter are also described in this thesis. Seven scale bars placed on a jig of cube shape were subject of the measurements (according to VDI/VDE 2634 standard). Two approaches were used in order to obtain measurement deviations – reference values, from which the measured data were subtracted to obtain deviations, were known due to the use of scale bars. Second approach consisted in evaluation of deviations from software Tritop Professional. The results showed that the number of photographs and shooting distance have the greatest impact on measurement accuracy of Tritop system. The accuracy was also influenced by number of coded targets in the scene or by use of the external green filter. Measured data were compared to the values obtained from predictive formulas. The results showed that the formula defined by the GOM company has a prediction accuracy of more than 96 %. However the formula is dependent on the input parameter called “Image accuracy” for which the value recommendations are made in this work. The results of this work can help predict measurement uncertainties more precisely and optimize the measurement methodology of Tritop photogrammetry system.
Problems of measurement and evaluation of switching loop impedance
Švéda, Miroslav ; Bárta, Jan (referee) ; Veselka, František (advisor)
This work is applied to questions about impedance of tripping loop. It deals with problems of measuring impedance of tripping loop, different measurement, procedures and accuracy of these measurements. Further, the work deals with the subsequent evaluation of the measuring impedance of tripping loop and writing of the measurement results. The work also focuses on the impedance of tripping loop in terms of the operation of the protective elements of the electrification system. Finally, the practical measurement of the impedance of tripping loop in real electrical circuits is performed as part of the work.
Determining the measurement accuracy of a coordinate measuring machine Zeiss UPMC Carat
Kiška, Roman ; Jankových, Róbert (referee) ; Šrámek, Jan (advisor)
The aim of this diploma thesis is to create a comprehensive study of measurement accuracy of coordinate measuring machine (hereinafter CMM) Zeiss UPMC 850 Carat S-ACC (hereinafter Zeiss Carat) for the needs of the national metrological institute in Brno in accordance with ČSN EN ISO / IEC 17025 and the follow-up system standards of the ČSN EN ISO 10360 series. Additionally, it includes the creation of instructions for the calculation of measurement uncertainty, which will be put into effect in an accredited calibration laboratory. The first part of the work focuses on the description of the current state of knowledge and the definition of basic concepts in the field of metrology and accurate measurements on CMM. The second part describes the Zeiss Carat measuring machine, identifies the individual contributors to the resulting measurement uncertainty and defines the methodology for their quantification. The last part deals with the evaluation of calibration data and the calculation of the expanded measurement uncertainty of the Zeiss Carat instrument, which is used to quantify its accuracy.
The use of nanofibres strain gauges for construction of linear sensors
Kirchner, Jan ; Kůr, Jan (referee) ; Pernikář, Jiří (advisor)
The aim of this thesis was to determine the basic characteristics of behavior of nanofiber strain gauges and on the basis of experimental measurements to confirm the suitability of the design of the length sensors. There was a product designed with a swivel arm whose rotation burdens the nanofiber strain gauge affixed to the flat side of the cut. Some measurements were carried out to find out a suitable direction of the loading pressure and to reveal the area showing the linear behavior. This linear area is approximately between 44 ÷ 92 % of the range of the nanostrain gauge (0% maximum load tensile, 100% maximum load pressure). Other measurements dealt with temporal stability of the output value at each point. The outcome of these experiments was to determine the methodology and to propose the design of sensors for further tests, the aim of which was to develop a sensor for measuring small diameters (from 1 to 5 mm). K
NEW PRINCIPLES OF GATE CAPACITANCE CHARACTERIZATION FOR SIGMA-DELTA MODULATORS
Sutorý, Tomáš ; Ďuračková, Daniela (referee) ; Husák, Miroslav (referee) ; Kolka, Zdeněk (advisor)
This thesis deals with the utilization of new principles of characterization of gate capacitances for sigma-delta modulators. Sigma-delta modulators are the integral part of sigma-delta analog-to-digital converters. The proposed new method is characterized by high resolution and modest requirements for laboratory equipment. It allows characterizing capacitances whose values are within the range which is used in sigma-delta modulators. The thesis contains description of the new method, the analysis of measurement accuracy and experimental results.
Electrical properties of modified oligobutadienes
Toulová, Jana ; Rozsívalová, Zdenka (referee) ; Frk, Martin (advisor)
Bachelor thesis deals with the behavior of dielectric materials in an alternating electric field. To identify the properties of dielectric materials in the frequency domain method was employed dielectric relaxation spectroscopy. On several samples of modified oligobutadiénů were measured frequency dependent components of the complex permittivity in the temperature range of negative temperatures, the ambient temperature.
Special length sensors
Pavliš, Jakub ; Prostredník, Daniel (referee) ; Jankových, Róbert (advisor)
This bachelor thesis contains a theoretical description of selected length sensors with emphasis on inductive and optical sensors. The main benefit of this thesis is the design and realization of a special inductive sensor with a small pressure force and an optical sensor with a resolution of 2.5 nanometers. In the thesis are analyzed the selected metrological properties of the designed sensors and the formulation of recommendations for their practical use.
Application of Sensors and Digitalization Based on IEC 61850 in Medium Voltage Networks and Switchgears
Štefanka, Martin ; Braciník, Peter (referee) ; Müller,, Zdeněk (referee) ; Toman, Petr (advisor)
Vzduchem izolované vysokonapěťové rozváděče jsou nedílnou součástí energetického distribučního řetězce a to jak v průmyslovém, tak ve veřejném sektoru. Hlavní funkcí rozváděče je ochrana pracovního personálu, rozpojování/odpojování a spínání, izolování, měření proudů a napětí, chránění a ovládání zatížení a komunikace dat do řídících systémů. V každé z výše zmíněných funkcí probíhal technologický vývoj v průběhu posledních 40 let. Dnešní rozváděče jsou spolehlivé a elektrickému oblouku odolné zařízení, zoptimalizované téměř k fyzikálním limitům dielektrických, elektromagnetických a termodynamických polí. Vakuové vypínače zajišťují stálou a spolehlivou vypínací funkci. Taktéž v oblasti chránění, řízení a komunikace došlo k mnoha technologickým proměnám. Od elektromechanických relé přes zařízení založená na tranzistorech, později na jednoúčelových mikroprocesorech, až po dnešní multifunkční vysoce výkonná mikroprocesorová inteligentní elektronická zařízení. Pouze oblast měření proudů a napětí setrvala z technologického hlediska posledních 40 let beze změny. K dominujícím měřícím technologiím dneška stále ještě patří indukčně založené transformátory proudu a napětí. Byly sice provedeny některé pokusy k obměně technologie měření jako takové, nicméně bez dosažení úspěchu. Tato dizertační práce je zaměřena na poskytnutí nového náhledu na alternativní technologii měření v elektrických sítích a ve vzduchem izolovaných vysokonapěťových rozváděčích, kterou lze využít jak pro měření proudu, tak i napětí. Tato práce vysvětluje, proč Rogowského cívky, odporové a kapacitní děliče jsou tou správnou volbou a měly by být použity ve vysokonapěťových rozváděčích a podrobně analyzuje přesnost měření a jejich příslušné meze. Dále tato práce popisuje, že pro nasazování nových měřících technologií musí být postupováno systematicky. Senzory připojené k inteligentním elektronickým přístrojům a schopností komunikace založené na IEC 61850 spolu s vysokorychlostní komunikační sběrnicí Ethernetu vytvoří systém, který zjednoduší a sjednotí konstrukci rozváděčů a umožní oddělit aspekty projektování měření od studie zkratových selektivit. V práci je také uveden příklad, jak tento nový systém může přinést změny a zjednodušení do oblastí projektování a řízení. V této práci jsou popsány výsledky několikaletého úsilí při stanovení nových měřících a digitalizovaných přístupů ve vysokonapěťových rozváděčích pod autorovým vedením. Toto úsilí také vedlo k uvedení nového produktu – UniGear Digital - konceptu od ABB. Závěrečná část práce demonstruje praktické nasazení všech výsledků v této práci při skutečných aplikacích.
Hodnocení přesnosti měření vlhkosti dřeva smrku při použití elektrického odporového vlhkoměru
Ondráček, Michal
This bachelor thesis focuses on the evaluation of the accuracy of spruce wood moisture measurement using an electrical resistance hygrometer. In the theoretical part, the basic properties of wood and its influence on moisture measurement are described. Furthermore, the different methods of measuring wood moisture are described and, above all, the principle of measurement using an electrical resistance hygrometer is discussed in detail. In the practical part, the moisture content of spruce wood was measured with three electric resistance moisture meters and the results were then compared with a reference gravimetric measurement method. Moisture meter No. 1 showed the most accurate results in determining the moisture content, but even it did not come close to the actual moisture content determined by gravimetry. Moisture meters 2 and 3 obtained identical measurements, but the measured moisture content differed significantly from the actual moisture content of the wood determined gravimetrically. These two hygrometers showed worse results than hygrometer No 1.