National Repository of Grey Literature 64 records found  beginprevious55 - 64  jump to record: Search took 0.01 seconds. 
The Lighting Equipment Used in Modern Vehicles and the Measurement of the Range of Visibility of the Main Headlights
Martínek, Michal ; Kropáč, František (referee) ; Vémola, Aleš (advisor)
This magister’s thesis is about modern lighting of vehicles, the visual range and afterglow in poor visibility. The first part of the thesis provides a detailed analysis of the current situation and problems, including a comprehensive description of the sources of light radiation, lamps, structures, and describe the systems used in modern lighting technology of vehicles. In the second part of the thesis there are the scientific methods to determine the issue of visual range and afterglow of the headlights. The second part is about the application of acquired techniques to detect an afterglow and the visual range of vehicles with modern headlights with a light source with xenon lamp, compared with a vehicle with a halogen lamp and a vehicle with an older halogen headlight.
Colour image histogram processing
Kučera, Ondřej ; Číka, Petr (referee) ; Říha, Kamil (advisor)
This bachelor thesis deals with processing of colour image histogram. To better undestanding of this problem it describes individual methods which edit colour image and its histogram. The thesis suggests a program implementation which allows processing of colour image and its histogram.
Reconstruction of the Janeček mill
Owczarzy, Denis ; Venkrbec, Václav (referee) ; Utíkalová, Ivana (advisor)
The task of this diploma thesis was the development of construction documents for the implementation of project, icluding project specialization. This is a rebuilding of the existing mill and it´s conversion to the object. Proposed reconstruction is solved with a sense of highlighting the exist building and expressing his dominance and function in an environment, where the building is located. From the original state was preserved only main building in historical style, and in contrast to this building were proposed two smaller objects with the background. The object is used as a pension for the accommodation for persons, restaurant and also provides rooms for seminars and meetings. Due to a brooklet flowing in front of the building and location of pension between the spa´s and city parks is the use of this building more than suitable.
Program for monitor testing
Matyáš, Pavel ; Prokeš, Aleš (referee) ; Michálek, Václav (advisor)
The goal of this term project are problems of LCD panels. The beginning of the term project is about theoretical description of particular types and features of actual LCD panels, origin of picture defects on computer monitors, measuring and picture quality testing methods of monitors. Practical part of project involves designing testing patterns and it's realisation in Borland Delphi development environment.
Compensation of geometric distortion of electrophoretic gel image
Dvořáček, Tomáš ; Vítek, Martin (referee) ; Škutková, Helena (advisor)
This master thesis is engaged in problematics of creation and compensation of geometric distortions in 1D agarose electrophoresis. This master thesis analyze the problematics of cause of these distortions and summarize the theory needed for compensation of these distortions. Based on acquired theory and created electrophoretic phantoms, the master thesis contains several suggestions for compensation of incurred distortions. These suggestions are recreated into functions, which are connected into a functional user interface for gel image analysis and geometric distortions compensation.
Assessment influence of the various aspects on the QoE in 3DTV: Subjective tests
Slíž, Martin ; Šindelář, Marin (referee) ; Boleček, Libor (advisor)
This thesis studies aspects influencing image quality 3D TV systems. Thesis is focused on comparing TV´s of the same brand with different diagonals and compares the change in perception of the evaluators by this parameter. The basic evaluated parameters are image depth, contrast, color rendition, image crossover and overall impression. Describes the creation of testing sequences for subjective tests, testing and evaluation of testing.
Controlling of camera
Tylš, Ladislav ; Valach, Soběslav (referee) ; Richter, Miloslav (advisor)
This thesis describes the principles of making application which is able to set and control camera. The first part describes basic camera connections and it explains definition and specification of camera’s features. The second part of my thesis describes implementation of application, which can use more cameras to image preview, image acquisition and to simply set of camera’s features. To implement the applications we can use MATLAB and C++BUILDER uses opencv libraries.
Optimization of tomographic station GE phoenix adjustment for plastic components including metal parts
Starý, Přemysl ; Petrilak, Michal (referee) ; Zikmund, Tomáš (advisor)
X-ray computed tomography is a tool mostly used in a medical diagnosis. A development of the technique and an improvement an in accuracy of tomographic systems enabled an utilization of the tomography in industrial applications. The tomography allows non-destructive analysis of inner structure. There is a negative influence of a reconstructed area if a low-absorption and high-absorption materials are scanned together. This influence makes analysis of the inner structure impossible. There are two options to eliminate these artifacts. We can use algorithms to reduce metal artifacts, or we can try to avoid them when performing the scan. This bachelor thesis focuses on an optimization of tomographic station adjustment for the plastic components including metal parts. The effect of an usage of X-ray filter or collimator and effect of a sample orientation on data quality will be observed. We use tools like contrast, noise and edge sharpness to evaluate data quality.
Polyfunction house Křenová
Láníková, Jaroslava ; Boháč, Ivo (referee) ; Šindlar, Jiljí (advisor) ; Pěnčík, Jan (advisor)
The multifunctional house is a part of the row of buildings lining the Krenova street. This house closes the whole line of buildings, so all the houses together create a functional unit. This multifunctional building is devided into three functional parts – a museum, an administrative part and flats. The centre of the building is used as a relaxing area – the atrium. The principle of the design is based on a simple line of block materials connecting to each other. In the front of the house, which is facing the Krenova street, will be situated the museum. The front facade is made of black and white tiles and decorated by a glass ashlar. A second glass ashlar is situated on the east side of the building – the administrative part. This east side will be visible from the newly planned town cirquit. The area in between this cirquit and the multifunctional house will be made into park and will use as a place for relaxation. The flats are situated into the quiet part of the street Skorepka
Monitoring the effects of new exposure parameters after transition to CR digital image processing in the Radiodiagnostic Department at Sušice Hospital, o.p.s.
KLIMENT, Karel
At the current time, doses of radiation caused by medical exposure make up the largest part of peoples' exposure to artificial sources of ionising radiation (SIR). Every medical exposure must be justified as of benefit to the individual subject to it. Radiation protection at the workplace is subject to the principle of optimisation. One of the paths leading to optimisation of radiation protection is the specification of the Local Diagnostic Reference Level (LDRL). The objective of this thesis was to test and evaluate whether and how transition to indirect digitisation affects image quality. According to model examinations on a water phantom, the lowest possible dose for which image quality would be preserved was to be determined. If the dose could be reduced, it would be possible to specify a new LDRL. The dose can be reduced, amongst other things, by making appropriate adjustment to exposure parameters on the control unit. I tested how changes in the exposure parameters set affected the quality of the resulting image. I used the water phantom for each examination which corresponded to the thickness of the area to be examined for a standard patient. For constant default voltage, first of all changes to the settings were made to reduced blackening and increase electrical charge. Subsequently, voltage was increased and reduced with a constant blackening level. Image quality was evaluated according to the measured values for noise, and high and low contrast resolution. I used the results to determine recommendations for specific examinations in terms of exposure parameters to be set. I worked out the LDRL for the new exposure parameter settings and compared it to the current LDRL values at the workplace and with the NDRL (National Diagnostic Reference Level).

National Repository of Grey Literature : 64 records found   beginprevious55 - 64  jump to record:
Interested in being notified about new results for this query?
Subscribe to the RSS feed.