Indoor environment of pool halls
Halla, Ondřej ; Rubina, Aleš (referee) ; Rubinová, Olga (advisor)
The diploma thesis deals with the problems of the indoor environment of swimming pool halls. Firstly, it describes issues and principles of designing HVAC system in the areas with high humidity production. Thesis then focuses on various approaches to calculations of evaporation from the water surface and different possibilities of dehumidification including different types of HVAC units. This knowledge was applied to the design of HVAC system for particular assigned building, for which are proposed two different solutions. Thesis includes experimental part, its aim is to analyse one specific critical part of the hall. Based on local surveying and long-term measurements a few possibilities of improvement are suggested.
Pension ventilation
Šplíchalová, Kateřina ; Blasinski, Petr (referee) ; Rubinová, Olga (advisor)
This bachelor's thesis deals with the explanation of the problems of air conditioning and the design of air conditioning units in a civil engineering building, more precisely in the pension. the work is divided into three parts. The first part deals with theory. It focuses on the principles, systems and types of air conditioning equipment. The second part is focused on the design of air conditioning units in the pension, there are three separate devices with a common drain to the exterior from the air conditioning engine room. The third part deals with project documentation.
Air conditioning for headquarters of shipping company
Šmardová, Eva ; Horák, Petr (referee) ; Rubinová, Olga (advisor)
This bachelor's thesis is focused on ventilation and cooling system for two-floor office building. The aim is to design air handling units to ensure optimal internal microclimate.
Airconditioning system for intensive care unit
Bosák, Jan ; Tesař, Zdeněk (referee) ; Rubina, Aleš (advisor)
The brachelor's dissertation deals airconditioning system, that operate clean spaces in the hospital. System is divide for two separate working unit. The first system operate surgical intesive care unit and next near spaces. The second system operate bed's rooms and their near spaces. The first systém shoulds smother thermal load operate's rooms in summer time and hot air ventilation in winter time. The second system does hot air ventilation whole year and It is refill fan-coils for smother thermal load. Both of them can adjust air humidity. Theory part of dissertation deals clean spaces with specialization on hospitals, for example operating theatre and intensive care unit.
Comfort Air Conditioning Systems and Application
Trávníček, Tomáš ; Košner, Jan (referee) ; Janotková, Eva (advisor)
This bachelor work deal with analysis factors determining state of inside environment of buildings, where human resides. In next step is mentioned research fission, comparison and using single comfort air conditioning systems. Some air conditioning make possible usage backward obtaining heat. In work are mentioned possibilities usage heat pumps.
Air-conditioning of offices in an industrial building
Drexler, Tomáš ; Pavelek, Milan (referee) ; Janotková, Eva (advisor)
Aim diploma thesis is design and dimensioning central air - conditioning system of offices in industrial object. To air - conditioning was choose 2nd floor office building. Introduction is devoted short entrance to the areas air - conditioning and survey used air - conditioner systems inclusive basic types and possibility using single air - conditioning system practically. Follows computational part, in which is effected heat loss calculation, summer heat gains air - conditioned object and psychrometr calculation summer and winter operationing air - conditioning system. After calculation needed parameters is effected design distribution air, machine - room air conditioning, dimensioning air channels and ventilators, design incoming and off-take anemostats and their regulations. Next part includes calculation power consumption during the operationing designed air - conditioning system.
Airconditioning in healthcare facilities
Růžička, Věroslav ; Jelínek, Ondřej (referee) ; Rubina, Aleš (advisor)
This bachelor thesis deals with design of air conditioning equipment serving the spaces of hospital inpatient ward and its associated facilities. Equipments designed in the computational part have the task to transport adapted fresh air to hospital premises. The system is devided into two units. Primary mechanism operates bedrooms and their sanitary facilities. Secondary mechanism operates associated facilities. Both mechanisms are designed so that hot air can ventilate in winter. To cover the heat load in summer, fancoil units are designed. Device number one is also able to manage the treatment of humidity. The theoretical part of the thesis focuses on air filters and filtration of atmospheric air.
Test bend for vehicle air-conditioning testing
Andrýs, Jan ; Hejčík, Jiří (referee) ; Štětina, Josef (advisor)
The aim of this work was to design test bend for vehicle air-conditioning. This test bend should simulate interior of the car and the engine compartment. Electric motor is used to drive compressor in test bend. Air supplied to test bend is modified to extreme conditions and the volume of supplied air is the same as the car drove at 50 km/h. Main frame of test bend is made from aluminium profiles manufactured by Bosch Rexroth, which provides great modularity. Walls are made from insulated panels by ELCOM System, they have very good insulation and are strong so additional equipment can be installed inside. Construction design was made is SolidWorks with 3D models of test bend as output. Air-conditong parts which were used as samples are originally from Skoda Octavia II. For this vehicle were made calculations of heat loads. In conclusion is simple testing example for this test bend and although there are some examples for future measuring.
The effect of the ventilation settings on amount of fed air and its distribution in the car cabin
Poláček, Filip ; Fojtlín, Miloš (referee) ; Pokorný, Jan (advisor)
This thesis deals with measuring of the distribution and volume of intake air inside vehicle cockpit under varying outdoor conditions and air conditioning settings. Fan characteristic was developed to determine the volume of air taken inside the cockpit. The measuring was made using speed probes in climatic chamber, where different outdoor conditions could be simulated. Following the measurements there is dependence between the air distribution and the outside temperature. The diploma thesis presents source materials to develop a mathematical model of car cabin.
Identification and prevention of errors during the assembly of air-conditioning systems
Vyškovský, Jan ; Krbalová, Maria (referee) ; Kotek, Luboš (advisor)
The subject of this master thesis is identification and prevention of mistakes during assembly process of air conditioning system in automobile industry. Thesis was created at Halla Visteon Climate Control Company in the Nový Jičín. The theoretical part is dealing with failure mode and effect analysis and seven quality basic tools for detection of failure and prediction of the failure. The practical part is focused on identification and analysis of failures at the assembly line.

National Repository of Grey Literature : 249 records found   previous11 - 20nextend  jump to record:
Interested in being notified about new results for this query?