National Repository of Grey Literature 527 records found  beginprevious518 - 527  jump to record: Search took 0.01 seconds. 
Lasers in the metrology of optical frequencies
Lazar, Josef
Review contribution dealing with metrology of time and length, about etalons of optical frequencies and present development and future of this field of research.
Laser interference nano-comparator for length sensor calibration in nanometric scale
Číp, Ondřej ; Mikel, Břetislav ; Čížek, Martin ; Šmíd, Radek ; Buchta, Zdeněk ; Lazar, Josef
In the work we present new laser measuring system for precise calibrations of length measuring transducers. This gauge is called nano-comparator because the resolution of the positioning of the measuring probe is in order of nanometers. The gauge works fully self-controlled and it is equipped by control software which is able to calibrate wide area of transducers. We put main stress to compensating of thermal dilatation of the gauge body and to eliminating of imperfection of linear guide ways which are used for positioning of the testing probe of the gauge. The work presents the first records of scale calibration of an incremental transducer.
Exploze drátku ve vodě
Prukner, Václav ; Koláček, Karel ; Schmidt, Jiří ; Frolov, Oleksandr ; Štraus, Jaroslav
The paper reports on the first experimental results of a new-built apparatus which is designed as soft X-ray source of coherent radiation with wavelength 14 nm. The radiation could be produced by the wire explosion in a liquid where the proximity of liquid wall can stabilize plasma similarly as proximity of solid wall stabilizes a Z-pinch in a capillary. The first part of this paper describes construction of the new device. In the second part are published first experimental data of wire explosion tests of the device which means time dependences of charging voltage and current.
Nová diagnostika pomocí Thomsonova rozptylu pro tokamak COMPASS
Aftanas, Milan ; Bělský, Petr ; Böhm, Petr ; Weinzettl, Vladimír ; Brotánková, Jana ; Barth, R. ; van der Meiden, H.
The COMPASS tokamak, originally from UKAEA, Culham laboratory, U.K., will be reinstalled at Institute of Plasma Physics, Prague. The scientific programme is focused mainly on the investigation of the edge plasma region with high temperature and density gradients called pedestal. Many innovations will be done and new diagnostics have to be constructed. One of the key diagnostics is an incoherent Thomson scattering for measurements of electron temperature Te and density ne with a high spatial resolution. Several construction options are considered. In this paper a possibility of using a Nd:YAG laser in combination with a detection system based on Avalanche Photodiodes is discussed.
Nová diagnostika pomocí Thomsonova rozptylu pro tokamak COMPASS
Brotánková, Jana ; Bělský, Petr ; Weinzettl, Vladimír ; Böhm, Petr
The COMPASS tokamak is being re-installed at IPP Prague after its transfer from Culham, U.K. Within the innovation, new diagnostics will be constructed, including a High Resolution Thomson Scattering System measuring electron temperature (Te) and electron density (ne) profiles. Scientific programme of the COMPASS tokamak is focused on the pedestal studies, thus the main stress will be laid on the edge part of the system.
Využití modelových spekter ke stanovení vhodných parametrů kapilárního výboje pro zesílenou emisi Balmerova alfa – přechodu H–like N (13,4 nm)
Štraus, Jaroslav ; Koláček, Karel ; Schmidt, Jiří ; Frolov, Oleksandr ; Prukner, Václav
Our capillary-discharge driver CAPEX-U, as many other pulsed-power devices, requires very accurate triggering of high-voltage gas switch. Laser-triggered switches offer many advantages over electrical triggered ones in terms of reproducibility, reliability, suitability for multi-gap or multi-channel operation and electrical isolation from the main high-voltage pulse. Results on the simultaneous initiation of four-channel high voltage spark gap by a neodymium dopped yttrium aluminium garnet (Nd:YAG, λ=1064 nm) laser are presented. The switch is pressurised with SF6 and N2 and holds off voltage about 500 kV at a gap separation of 13 mm. Electrical parameters of the spark channels are obtained from the comparison of experimental and modelling (equivalent circuit) results.
Workplace for stabilization of laser frequency
Buchta, Zdeněk
This paper describes a new appliance for demonstration of frequency stabilization of a laser diode. That is an original solution which is appointed for hands-on teaching students of optoelectronic courses. The arrangement consists of a laser diode driver, temperature controller and driver for the photodetector.
Laserové řezání CVD diamantových plátků
Chmelíčková, Hana ; Stranyánek, Martin ; Rosa, Jan ; Vaněček, Milan
CVD diamond wafers with diameter 51 mm and thickness from 0,1 mm to 0,7 mm are necessary to cut to different shapes. Cutting technology by means of pulsed Nd:YAG laser was developed to successful dividing of thin pieces
Market analysis of industrial marking lasers and draft marketing strategy for the company MEGAFLEX
Valterová, Martina ; Stříteský, Václav (advisor) ; Dušek, Jiří (referee)
This master thesis is focuses on a market analysis of industrial marking lasers in the Czech Republic. In the theoretical part are described appropriate methods of strategic analysis for Business-to-Business market. The strategic analysis is divided into two parts, descriptive and comparative one. The application part characterizes the market of industrial marking lasers and describes also macro, micro and internal environment of the company MEGAFLEX. A partial goal of this thesis is to propose a marketing strategy, which can be used as a basis for the development of strategic marketing plan.

National Repository of Grey Literature : 527 records found   beginprevious518 - 527  jump to record:
Interested in being notified about new results for this query?
Subscribe to the RSS feed.