National Repository of Grey Literature 97 records found  beginprevious78 - 87next  jump to record: Search took 0.00 seconds. 
Thermodiagnostics – contact and contact-free temperature measurements
Mikula, Martin ; Jankových, Róbert (referee) ; Hammer, Miloš (advisor)
This thesis is concerned with thermodiagnostics in industrial practise, which is very important for the assessment of technical condition of object on the basis of temperature, in today's time. It includes summary of contact and contact-free methods and their principle, advantages and disadvantages for aplication in industrial practise. Because of thesis it was carried out measurement in company Daikin Device Czech republic with the use of contact thermometer and two available thermocameras for solving of topical tasks relating to production.
Verification of the model for predicting the properties of the combustion process
Horsák, Jan ; Kilkovský, Bohuslav (referee) ; Jegla, Zdeněk (advisor)
This work thoroughly analyzes a previously created computational model for predicting characteristic properties of the combustion process in an experimental combustion chamber. Any found shortcomings of the original model are removed and the model is further improved prior to its application on 11 real cases of combustion tests performed at various conditions and with various fuels. Data provided by the model are confronted with the data obtained during the combustion tests and the model accuracy is evaluated, based on local heat flux along the length of the combustion chamber. Finally, the overall usefulness of the model is determined by the means of evaluating the acquired accuracy values, and further possibilities of model improvement and use are presented.
The use of thermovision technology in output control of power supplies
Rejžek, Jan ; Slaný, Martin (referee) ; Polzer, Aleš (advisor)
The aim of the thesis is to clarify the issue of non-contact surface temperature measurement with a focus on the thermal imaging cameras as a modern representative of pyrometers and thermovision technology used in the output control of power supply. To obtain the corresponding results of temperature control, it is necessary to know the exact values of emissivity of the measured materials. The experimental part of this thesis is focused on detection of emissivity of power supply parts.
Measuring of emissivity of wet and dry surfaces
Brzobohatý, Tomáš ; Janotková, Eva (referee) ; Pavelek, Milan (advisor)
The objective of this thesis is to create summary of emissivity of wet surfaces, emissivity of rime surfaces and emissivity of dry surfaces. The next objective is to create materials for termovision measurement and find the use for this materials for practice. Theoretical part of thesis deals with a theory of ways of heat transfer (radiation mainly), description of emisivity concept, description of emisivity finding ways and the show emissivity of mesuared materials from avaible sources for working hypothesis. Emissivity of dry, wet and rime samples were measured as the experimental part of thesis. Experimental part of thesis consist of experiment description, working hypothesis, measuring instruments and measuring area description, measuring proces description and presentation of measured results. Obtained dependences are benefits for termovision measurent, energy evaluation and the thermal state microclimate simulations.
Calculation methods for tube banks heat exchanger
Housírek, Jiří ; Jegla, Zdeněk (referee) ; Kilkovský, Bohuslav (advisor)
This diploma thesis deals with calculation methods of heat exchanger with cross-flow tube bundle. The first part of the thesis contains summary of generally known basic calculation relations used in calculations of heat exchangers and a detailed description of a given heat exchanger.The second part of the thesis provides a description of available calculation methods of a given aparatus required for its thermal and hydraulic calculation. The final part describes application POST in 1.0 which has been formed on the basis of these calculation methods. Using this application check calculation of exchanger with cross-flow tube bundle was carried out and gained figures compared with results gained by means of professional calculation program HTRI.
Emissivity and Result of Non-Contacting Temperature Measurement
Kotrba, Martin ; Zuth, Daniel (referee) ; Vdoleček, František (advisor)
Detailed introducition of non-contact temperature measurement and correct settings of the measurement device, which has great influence on correct temperature determination, is the aim of this diploma thesis. The experimental laboratory was established to verify dependencies by Compaq CM non-contact thermometer. Conclusions and recomendations are deduced from the measurement results and their analysis.
Accuracy of non-contacting Temperature Measurement
Horák, Ladislav ; Janečka, Jan (referee) ; Vdoleček, František (advisor)
This master’s thesis is specialized on the influence of correct parameters of emissivity, which depends on the temperature, wavelength and ambient environment. The investigation the parameter was taken infrared non-contact thermometer MI3 from company Raytek. To improve the quality of measurement was designed and programmed measuring utility program. The program was developed in the LabView 8.5 programming environment. To obtain the true value of the measured temperature of the target was designed and constructed the touch thermometer with the resistance dependent sensor. The thermometer is connected to the communication box of infrared thermometer and contain the same program. Nowadays are the most advanced IR thermometer with fixed parameters emissivity, which is applicable just to the real body in the vicinity of the parameter emissivity 0,95. For those IR thermometers were designed correction function, which would have temperature measured at a fixed emissivity parameter 0,95 set close to the actual value of the object.
Contactless measurement of surface temperatures in mechanical engineering
Frňka, Tomáš ; Forejt, Miloslav (referee) ; Polzer, Aleš (advisor)
The subject of this thesis is the incorporation of the contactless temperature measurement of surface temperatures among other methods of temperature measurement with the analysis of (individual) advantages and disadvantages. The study is focused on the measurement and finding alternative protective clingfilms for thermo camera “Flir SC2000” and possible ways of their usage.
Verification of thermal-insulation properties of the foil materials
Šot, Petr ; TROJAN,, Karel (referee) ; Šťastník, Stanislav (advisor)
The master´s thesis deals with verification of thermal insulating property of thermoreflection foil insulations. The teoretical part of thesis focuses on the energy demand of buildings, the problems of heat transfer material, terms required for study of thermoreflection thermal insulation and experimental methods for determination of thermal insulating properties of insulators. In the next part the chapter is accompanied by an overview of the most common insulation materials which used in construction. The last part of teoretical part is devoted to the description of thermoreflect formation and analysis of the spread of thermal insulating layers of thermoreflection thermal insulation. The first part of thesis is devoted to the use of thermoreflection therm insulation in buildings. The second part of thesis is devoted to the design, assembly and calibration of the measuring device that uses a method of protected warm chamber. It is declared as a binding method of detection of the heat transfer performance of thermoreflection thermal insulation. The developed measuring device allows detection of endpoints in some direction of propagation of heat. Measurment of heat transfer coefficient devoted the third part of practical part. This part contains a description of the samples used for the measurement of the heat transfer coefficient. In the fourth chapter of the practical part are presented the results of the heat transfer coefficient measurments on selected samples of thermoreflection foil insulation. It is shown the characteristic of heat transfer coefficient of individual samples, the dependence of the heat transfer coefficient on the position of the sample in the measuring device and the recommendation of an appropriate use of sample in the works for the climatic conditions of the Czech republic. The work concludes the chapter of comparing and evaluating of all samples with practical recommendations.
Contactless temperature measurement
Závodný, Ondřej ; Bejček, Ludvík (referee) ; Beneš, Petr (advisor)
In this bachelor thesis I outlined the problems of non-contact measurement and practical verification of the basic parameters thermo camera Fluke Ti20. It is especially on the experimental measurement of the source of the reference temperature and the product to demonstrate the impact of emissivity. The aim of this work is a practical verification thermo cameras parameters, the determination of uncertainties and to explore the effects of parasitic repeated measurements. The basic part is a brief recorded history, the general relations and principles of the non-contact measurement, as well as their own use and typical parameters. In the next chapter you more acquainted with itself thermo camera, properties and basic parameters. The practical part is about the measurement itself. The main objective then was to verify the accuracy of reported thermo camera and examining the impact of emissivity.

National Repository of Grey Literature : 97 records found   beginprevious78 - 87next  jump to record:
Interested in being notified about new results for this query?
Subscribe to the RSS feed.