Název:
Voltammetric determination of anticancer drug flutamide at screen-printed carbon electrodes
Autoři:
Vyskočil, V. ; Navrátil, Tomáš ; Barek, J. Typ dokumentu: Příspěvky z konference Konference/Akce: Moderní elektrochemické metody /31./, Jetřichovice (CZ), 2011-05-23 / 2011-05-27
Rok:
2011
Jazyk:
eng
Abstrakt: Flutamide, 4-nitro-3-trifluoromethyl-isobutylanilide, is the active component of a synthetic nonsteroidal antiandrogen drug, which is commonly used in the treatment of advanced prostate cancer. In this contribution, optimum conditions have been found vor voltammetric determination of flutamide by DC voltammetry (DCV) and differential pulse voltammetry (DPV) at screen-printed carbon electrodes (SPCEs). Under optimum conditions (Britton-Robinson buffer pH 7.0 - methanol (9:1)), linear calibration curves were measure with limits of quantification 6x10(-7) molL(-1) and 8x10(-7) molL(-1) for DCV at SPCEs, respectively. The newly developed methods were successfully applied to the determination of the drug in pharmaceutical formulation Apo-Flutamide (Eulexin tablets).
Klíčová slova:
creatine; flutamide; screen-printed carbon electrodes Číslo projektu: CEZ:AV0Z40400503 (CEP), IAA400400806 (CEP), GAP206/11/1638 (CEP) Poskytovatel projektu: GA AV ČR, GA ČR Zdrojový dokument: Sborník přednášek. XXXI. Moderní elektrochemické metody, ISBN 978-80-254-9634-3
Instituce: Ústav fyzikální chemie J. Heyrovského AV ČR
(web)
Informace o dostupnosti dokumentu:
Dokument je dostupný v příslušném ústavu Akademie věd ČR. Původní záznam: http://hdl.handle.net/11104/0197638