Název: Experimental Determination of Human Arm Force/Elbow Joint Angle Relation
Autoři: Krejsa, Jiří ; Zezula, M. ; Věchet, Stanislav
Typ dokumentu: Příspěvky z konference
Konference/Akce: Engineering Mechanics 2010, Svratka (CZ), 2010-05-10 / 2010-05-13
Rok: 2010
Jazyk: eng
Abstrakt: The achievable force at the end of human forearm depends on the forearm position. The actual value of this force is one of the most important variables affecting the design of the motorized splint, but reliable data are hard to find. Sophisticated measuring device was constructed to determine this force. The force is measured during the movement of the forearm, as such method yields better results than static measurement. The trajectory of movement is enforced by the measuring device, so the influence of the subject on the trajectory is eliminated.
Klíčová slova: human arm force measurement; intelligent orthosis
Číslo projektu: CEZ:AV0Z20760514 (CEP)
Zdrojový dokument: Engineering Mechanics 2010, ISBN 978-80-87012-26-0
Poznámka: Související webová stránka: http://www.engmech.cz/

Instituce: Ústav termomechaniky AV ČR (web)
Informace o dostupnosti dokumentu: Dokument je dostupný v příslušném ústavu Akademie věd ČR.
Původní záznam: http://hdl.handle.net/11104/0186016

Trvalý odkaz NUŠL: http://www.nusl.cz/ntk/nusl-41499


Záznam je zařazen do těchto sbírek:
Věda a výzkum > AV ČR > Ústav termomechaniky
Konferenční materiály > Příspěvky z konference
 Záznam vytvořen dne 2011-07-01, naposledy upraven 2024-01-26.


Není přiložen dokument
  • Exportovat ve formátu DC, NUŠL, RIS
  • Sdílet