National Repository of Grey Literature 19 records found  1 - 10next  jump to record: Search took 0.00 seconds. 
Precise Frequency Generator - DDS
Kratochvíl, Petr ; Vágner, Petr (referee) ; Baran, Ondřej (advisor)
This work deals with frequency generators based on the direct digital synthesis method DDS. Basic principles and attributes of the frequency generator DDS are explained. The text describes parameters influencing and defining a quality of the generated signal. The list of available integrated circuits realizing the direct digital synthesis is mentioned. A construction of the DDS generator with a device AD9954 and the generator control are described. At the end of the work, the function and parameters of the designed generator are verified.
BER Meter for Video Signals
Šimoník, Petr ; Frýza, Tomáš (referee) ; Říčný, Václav (advisor)
The diplomma thesis is dealing with possibilities of Signal to noise ratio measurement by method, which is based on direct measurement. It is chosen the most suitable method – signal and noise separation to two different parallel signal branches, where is measured signal strength in one branch and root mean square value in the other. The thesis is consisted of a concept of detail block scheme of Signal to noise ratio meter, which was designed in terms of theoretical knowledge. Particular functional blocks were circuit-designed, the active and passive parts were chosen and their function were described. There were made simulation and displayed input and output time flows. There is designed the whole connection of engineered Signal to noise ratio meter in the last part of my thesis. The double-sided board of printed circuit is contained too. It was created simple programme for supervisor micro-processor. Thereby were constructed complete bases for realization.
MRI Acquisition and Preprocessing of Image Sequences for Clinical Perfusion Imaging
Krchňavý, Jan ; Bartoš, Michal (referee) ; Jiřík, Radovan (advisor)
This thesis describes the theory for static and dynamic magnetic-resonance imaging using contrast agents affecting T1 relaxation time. The available acquisition methods in the specified facility of Masaryk Oncological Institute in Brno are described. The sequences for subsequent experimental measurements are selected. The used phantoms are described. Acquisition protocol for measuring is described briefly and the evaluation method for the measured data is suggested. The best acquisition sequence and a method of measurements is chosen influenced by estimation of relaxation time T1, sensitivity and signal to noise ratio. Perfusion analysis is executed and perfusion parameters are calculated. The work was supported by the European Regional Development Fund and the State Budget of the Czech Republic (RECAMO, CZ.1.05/2.1.00/03.0101).
Pause Identification in Degraded Speech Signal
Podloucká, Lenka ; Balík, Miroslav (referee) ; Smékal, Zdeněk (advisor)
This diploma thesis deals with pause identification with degraded speech signal. The speech characteristics and the conception of speech signal processing are described here. The work aim was to create the reliable recognizing method to establish speech and non-speech segments of speech signal with and without degraded speech signal. The five empty pause detectors were realized in computing environment MATLAB. There was the energetic detector in time domain, two-step detector in spectral domain, one-step integral detector, two-step integral detector and differential detector in cepstrum. The spectral detector makes use of energetic characteristics of speech signal in first step and statistic analysis in second step. Cepstral detectors make use of integral or differential algorithms. The detectors robustness was tested for different types of speech degradation and different values of Signal to Noise Ratio. The test of influence different speech degradation was conducted to compare non-speech detection for detectors by ROC (Receiver Operating Characteristic) Curves.
ECG quality evaluation
Vencel, Michal ; Vítek, Martin (referee) ; Smital, Lukáš (advisor)
This seminar work deals with the topic of evaluating the quality of ECG signals. The introductory chapters explain the basic characteristics of ECG signals - measurement, the form of the measured signal, methods of analysis. The cardiac physiology and pathology is presented. The most common types of noise that occur in ECG signals are also mentioned. Further, the reader is acquainted with the importance of the issue of evaluating the quality of ECG signals. In the practical part of the work, two own methods for ECG quality evaluation are presented. First, a brief theoretical introduction to the techniques used in the creation of methoda is given, followed by a description of the principle of algorithms. In order to compare the functionality of the proposed methods, three more methods from other authors are presented. Their principle is briefly described. In the final chapter, all methods are subjected to functionality testing. The results are examined and all methods are compared with each other.
Automated workplace for amplifier parameters measurement
Jurčík, Petr ; Čejka, Miloslav (referee) ; Havlíková, Marie (advisor)
The aim of this work is to create an automated workplace for measuring the basic parameters of audio amplifiers using a graphical programming environment LabVIEW. Subsequently, the functionality will be verified in practical measurements on the real amplifier.
Analysis and prediction of data traffic in mobile ad hoc network
Konečný, Daniel ; Koutný, Martin (referee) ; Hošek, Jiří (advisor)
The diploma thesis „Analysis and prediction of data traffic in mobile Ad Hoc network“ focuses on the radio propagation models of services in MANET (Mobile Ad-hoc) networks. It describes MANET networks and covers the theoretical analysis of routing protocols, radio wave propagation and propagation models of simulation enviroment NS-3 (Network Simulator 3). Furthermore, there is processed the creation process of model MANET networks with the routing protocol AODV (Ad Hoc On Demand Distance Vector) in the simulation environment NS-3. For analysis purposes there were implemented new functions to capture value of SNR (Signal to Noise Ratio) and throughtput. For this reason a physical layer of one of NS-3 model was modified. As an result there is a simulation build that compared several number of propagaion models.
Speech quality objective methods
Kovařík, Jiří ; Balík, Miroslav (referee) ; Sysel, Petr (advisor)
In terms of the bachelor´s thesis was created a computer programme for the quality speech estimation. This programme was created in the MATLAB programming language using GUI programing environment. Through the use of created programme was processed group of records disturbed by various noises from the real environment. As a speech quality objective methods was chosen classical SNR, Segmental SNR, PESQ, Itakura distance, Itakura – Saito distance For this programme were created service instructions. In this work are these speech quality objective methods described furthermore the process of the human voice creation, speech modeling and a linear predictive coding.
ECG quality evaluation
Vencel, Michal ; Vítek, Martin (referee) ; Smital, Lukáš (advisor)
This seminar work deals with the topic of evaluating the quality of ECG signals. The introductory chapters explain the basic characteristics of ECG signals - measurement, the form of the measured signal, methods of analysis. The cardiac physiology and pathology is presented. The most common types of noise that occur in ECG signals are also mentioned. Further, the reader is acquainted with the importance of the issue of evaluating the quality of ECG signals. In the practical part of the work, two own methods for ECG quality evaluation are presented. First, a brief theoretical introduction to the techniques used in the creation of methoda is given, followed by a description of the principle of algorithms. In order to compare the functionality of the proposed methods, three more methods from other authors are presented. Their principle is briefly described. In the final chapter, all methods are subjected to functionality testing. The results are examined and all methods are compared with each other.
Influence of working conditions on the detected signal by BSE detector in the scanning electron microscope Vega 3 XMU
Tkáčová, Tereza ; Chladil, Ladislav (referee) ; Čudek, Pavel (advisor)
This work is focused on investigating of influence of different working conditions in scanning electron microscope to signal detected by backscattered electron detector. In the theoretical part, there is a general description of scanning electron microscope, backscattered electrons issue and also definition of methods of signal to noise ratio evaluation. The practical part is focused on observation of suitable samples in a scanning electrone microscope.

National Repository of Grey Literature : 19 records found   1 - 10next  jump to record:
Interested in being notified about new results for this query?
Subscribe to the RSS feed.