National Repository of Grey Literature 203 records found  previous11 - 20nextend  jump to record: Search took 0.02 seconds. 
Modern coding of speech signals using overcomplete models
Zapletal, Ondřej ; Průša, Zdeněk (referee) ; Rajmic, Pavel (advisor)
The theoretical contents of this thesis are studies of overcomplete models. Those are the models of signals, on which is set for their parametrization more variables, than it's necessary and consequently there's computed so-called sparse solution via iteration algorithms. A goal of this analysis is a selection just of the considerable (sparse) parameters. The theory is based on a linear algebra, vector spaces, bases and so-called frames. The task of the individual project of this thesis is a description and simulation of two speech coders: a classical coder based on linear predictive speech coding and a coder, that's making use of overcomplete stochastic ARMA processes models. A part of their realization is to simulate their decoders and a analyze their reconstruction quality. For their realization there is used MATLAB and an overcomplete models' library (toolbox frames).
Precision audio preamplifier for headset measurement
Šimek, Michal ; Balík, Miroslav (referee) ; Hanák, Pavel (advisor)
This thesis deals with microphone and headphone preamplifier for microtelephone and headset. The design shall meet the electrical interface requirements set out in ITU-T Rec. P.381(08/2012). The design includes a voltage converter, microtelephone bias and both a battery and an external power supply. In this work is also described the design of printed circuit board and the solution of a low noise in the whole circuit. The aim of this thesis is to design, built and embed the laboratory fixture into a metal box. Finally, measure the product on an APx525 audio precision analyzer.
System for precise dynamic measurement of bridge sensors
Čech, Jonáš ; Kolka, Zdeněk (referee) ; Kubíček, Michal (advisor)
This master’s thesis deals with design of measurement system for dynamic measurement of bridge sensors. After a short theoretical part, the own concept is introduced. System can provide sampling rate up to 250 kSa/s with 24-bit resolution. The maximum number of samples is about one and a half milion. At first, the design of analog part was made, in this phase of design the digital part is based on evaluation board with ARM Cortex-M7 and external memory. After final choice of appropriate ICs, the analog and digital part will be integrated into one PCB.
ECG noise generator
Mikuláš, Karol ; Kozumplík, Jiří (referee) ; Hrubeš, Jan (advisor)
Real ECG signal contains undesirable artifacts arising from its capture. Due to loss of diagnostically useful information in the noise signal and followed by the filtering the signal is important to know the characteristics, the most common symptoms and causes, to avoid or minimize the noise ECG signal. ECG noise generator is an educational program designed to serve the learning methods of filtering the noise signal. The user program can verify the effectiveness of the chosen method and the extent of deformation of the useful signal. The program includes basic types of artifacts, such as powerline interference, baseline wander, drift, impulse noise, myopotentials and change of baseline wander of ECG signal, which can be prepared noise signal from a database or other signal selected by the user.
Optimization of tomographic station GE phoenix adjustment for plastic components including metal parts
Starý, Přemysl ; Petrilak, Michal (referee) ; Zikmund, Tomáš (advisor)
X-ray computed tomography is a tool mostly used in a medical diagnosis. A development of the technique and an improvement an in accuracy of tomographic systems enabled an utilization of the tomography in industrial applications. The tomography allows non-destructive analysis of inner structure. There is a negative influence of a reconstructed area if a low-absorption and high-absorption materials are scanned together. This influence makes analysis of the inner structure impossible. There are two options to eliminate these artifacts. We can use algorithms to reduce metal artifacts, or we can try to avoid them when performing the scan. This bachelor thesis focuses on an optimization of tomographic station adjustment for the plastic components including metal parts. The effect of an usage of X-ray filter or collimator and effect of a sample orientation on data quality will be observed. We use tools like contrast, noise and edge sharpness to evaluate data quality.
Noise, Transport and Structural Properties of High Energy Radiation Detectors Based on CdTe
Šik, Ondřej ; Lazar, Josef (referee) ; Navrátil, Vladislav (referee) ; Grmela, Lubomír (advisor)
Poptávka ze strany vesmírného výzkumu, zdravotnictví a bezpečnostního průmyslu způsobila v posledních letech zvýšený zájem o vývoj materiálů pro detekci a zobrazování vysokoenergetického záření. CdTe a jeho slitina CdZnTe. jsou polovodiče umožnují detekci záření o energiích v rozsahu 10 keV až 500 keV. Šířka zakázaného pásma u CdTe / CdZnTe je 1.46 -1.6 eV, což umožňuje produkci krystalů o vysoké rezistivitě (10^10-10^11 cm), která je dostačující pro použití CdTe / CdZnTe při pokojové teplotě. V mé práci byly zkoumány detektory CdTe/CdZnTe v různých stádiích jejich poruchovosti. Byly použity velmi kvalitní spektroskopické detektory, materiál s nižší rezistivitou a výraznou polarizací, detektory s asymetrií elektrických parametrů kontaktů a teplotně degenerované vzorky. Z výsledků analýzy nízkofrekvenčního šumu je patrný obecný závěr, že zvýšená koncentrace defektů způsobí změnu povahy původně monotónního spektra typu 1/f na spektrum s výrazným vlivem generačně-rekombinačních procesů. Další výrazná vlastnost degenerovaných detektorů a detektorů nižší kvality je nárůst spektrální hustoty šumu typu 1/f se vzrůstajícím napájecím napětí se směrnicí výrazně vyšší než 2. Strukturální a chemické analýzy poukázaly, že teplotní generace detektorů způsobuje difuzi kovu použitého při kontaktování a stopových prvků hlouběji do objemu krystalu. Část mé práce je věnována modifikaci povrchu svazkem argonových iontů a jejímu vlivu na chemické složení a morfologii povrchu.
Real-Time Volumetric Terrain Rendering
Koblížek, Aleš ; Kobrtek, Jozef (referee) ; Matýšek, Michal (advisor)
Tato práce popisuje způsob implementace volumetrického terénu s důrazem na modifikovatelnost v reálném čase. Použitá datová struktura je bitové pole - materiál terénu není potřeba ukládat, takže pro uložení každého vzorku stačí jeden bit. Textura je odvozována na základě sklonu terénu. Vizualizace se provádí převodem na povrchovou reprezentaci pomocí algoritmu pochodující kostky a následným zobrazením polygonové sítě pomocí vykreslovacího řetězce. Terén i textura jsou generovány procedurálně. Pro rozrušení poměrně pravidelného povrchu je použit displacement mapping a teselace. Jemnější detaily jsou získány pomocí bump mappingu. Pro dynamické stíny je použit shadow mapping.
Low-noise bandgap reference
Knop, Jaroslav ; Fujcik, Lukáš (referee) ; Kadaňka, Petr (advisor)
This work deals with principles of design low noise bandgap reference using multiple in the process EPI92. The voltage reference is described and theoretic analysis noise performances is made. Results are compared with measured data realized breadboard BG reference and fabricated low drop-out regulators, which using different accurate bandgap references cells.
Adaptive filtering of ECG Signals
Nejezchleba, Zdeněk ; Kozumplík, Jiří (referee) ; Smital, Lukáš (advisor)
The aim was to test the methods for suppression 50 Hz noise with adaptive filtering. When using the general scheme of adaptive and deterministic scheme to suppress hum. The work is a theoretical derivation of adaptive algorithms and some examples of modeling in MATLAB.
Precise Audio Amplifier for Quality Listening
Janošík, Lukáš ; Šotner, Roman (referee) ; Kratochvíl, Tomáš (advisor)
This bachelor thesis deals with a design of quality audio preamplifier designed for high quality production. The typology of whole design emphasizes very important transmission properties, i.e. high signal-to-noise ratio, high separation of channel, low distortion, The content of the semestral thesis is an symetrical input, relay input switch, 5 band equalizer with bypass and symetrical output with active line driver.

National Repository of Grey Literature : 203 records found   previous11 - 20nextend  jump to record:
Interested in being notified about new results for this query?
Subscribe to the RSS feed.