National Repository of Grey Literature 317 records found  beginprevious288 - 297nextend  jump to record: Search took 0.02 seconds. 
BIKEZONE.cz - Bikeshop with flats
Barták, Martin ; Šuhajdová, Eva (referee) ; Šuhajda, Karel (advisor)
The aim of the diploma thesis „BIKEZONE.CZ – bikeshop with flats“ is development of detailed documentation to build the bikeshop with flats for permanent living for sixty person on the land number 337/4, in the city named Hradec Králové – Kukleny. The building is designed with the master plan and the surrounding construction and appropriately mounted on the adjacent intersection. The building is designed as a four-floors, partial basement with two-floors bikeshop with own service and the flat part with seventeen flats of the size two or three bedrooms with kitchen. Next to building are designed two car parkings with capacity for 25 cars. The main entrance to the shop is from the street Pražská třída where is a parking for customers a the main entrace to the flat house is from the street Pálenecká. The supporting part will consist of a combination of sand-lime bricks KM BETA and monolithic ceiling and column. The non-supporting part will of sand-lime bricks KM BETA. The roof is flat with a waterproofing membrane of flexible PVC surcharge laundered gravel. Insulation of the building envelope will contact system ETICS terminated blending facade of dark and light gray colors. Doors and windows are wooden with golden oak color shade.
Assessment of defects and faults of ETICS Systems
David, Jan ; Láník, Jaromír (referee) ; Schmid, Pavel (advisor)
This diploma thesis discusses the problems of defects and faults of external thermal insulation composite systems. The first part describes the correct procedures for application systems, the next part describes defects, faults and their causes and the end of the thesis describes the contactless diagnostic methods used for the survey of ETICS. This part is mainly focus on detection of anchors. The example shows the calculation of anchoring.
Usage og logical matrixes for detection of causes of defect and failures of external contact thermal insulation systems
Zvěřina, Aleš
Defects and failures of ETICS can occure due to many causes. Determination of primary cause of defects or failures can be very difficult, mainly if the building is complicated. There can be many interactions between participants of building proces (architect, builder, investor, technical supervisor of investor), used materials, parts of documentation, climatic conditions and the like. The usage of elements of systemic entry of forensic engineering, specifically logical matrixes, for example matrix of hypothesis or matrix of signs can be very advantageous. The goal of the article is to show a usage of logical matrixes on real application of ETICS crash. The primary cause determination will be find from testing results. The part of article discuss possible computer processing of logical matrixes.
The influence of the outdoor temperature on the properties of the reinforced layer in the implementation of ETICS
Novotný, Michal ; Gašparik,, Jozef (referee) ; Schmid, Pavel (referee) ; Sedlák,, Petr (referee) ; Lízal, Petr (advisor)
The trend in today's civil engineering are growing demands for quality and comfort constructed buildings and spaces in them. This trend causes a change in the approach to designing buildings and building new buildings. One of the main directions great importance is attached dedicated reconstruction of buildings and their technical adjustments to meet the ever increasing demands being norms and laws. One of the most monitored parameters are thermal-technical characteristics of objects - i.e. better quality means saving on heating costs. In this connection there is a big trend of the modern construction industry and building insulation, mainly ETICS systems. Dissertation focuses on the basic (reinforced) layer of the ETICS and examines the effect of low temperatures, acting on the matter in the implementation of the system, the properties of this layer. This coating is one of the key elements of the system, which more or less determines the quality and durability of the system. The first part deals with the current state of the problem and generally insulation systems, basic types and the advantages and disadvantages of these systems. In the main part of the work is solution focused work, its objectives and methodology for testing materials using laboratory tests and are mentioned outputs of experiments in terms of results. The final section addresses the evaluation of the data and results and output for construction practice. The theme of work was also addressed in the specific research. The works are also numerical and graphical attachments to records of experiments and calculations.
DURABILITY AND MAINTENANCE OF EXTERNAL THERMAL INSULATION COMPOSITE SYSTEMS
Remeš, Hynek ; Fridrichová, Marcela (referee) ; Kolář,, Karel (referee) ; Steuer, Radek (referee) ; Žižková, Nikol (advisor)
External thermal insulation composite system (ETICS) is a widespread method appearance of the facades of existing and new civil and industrial buildings. With its frequent application becomes engaged his durability issues and possible rehabilitation and more topical. Influences affecting durability ETICS is still under investigation, as well as systematic and practical way to usable redevelopment. The main theme of this work is to summarize knowledge in ETICS issue, particularly from the viewpoint adhesive and leveling materials based on Portland cement and final finishes. The theoretical part is discussed ETICS composition, the composition of its components, technical requirements and factors affecting durability. The experimental part focuses on the redevelopment of ETICS and verification using colloidal silica for modification of construction materials, which are part of the ETICS.
Possibilities of nondestructive diagnostics of ETICS
Zvěřina, Aleš
Article deals with possibilities of nondestructive diagnostics of exthernal thermal inulation systems (ETICS) and compares possibilities of 3 used and researched methods. Infrared thermography, which is one of most used method, impedance defectoscopy, a method, which has been used for investigating of flat roof for 3 years and radar diagnostics, using for reverse reconstruction of anchor plans of ETICS. A special focus is dedicate to impedance defectoscopy, becouse the results of this method is possible to display clearly as results on thermograms from infrared thermography.
Brewery
Dědičová, Helena ; Bartolšic, Vít (referee) ; Matějka, Libor (advisor)
This thesis deals with the design of brewery in Litomyšl. Brewery with beer production 2000hl per year and restaurant for 140 guests and kitchen have the main function of the building. The building is designed as one construction object and its built-up area is 472,2 square meters. The building has a partial basement, two floors and it has structural masonry system. A load-bearing walls of two floors are formed by clay masonry and the load-bearing walls of the basement are formed by permanent formwork. A roof of the building is a flat roof with a slope of 3 percent and the finish is made of modifed bitumen membrane.
Kindergarten Adaptation to Contemporary Living
Peciarová, Gabriela ; Juračková, Edita (referee) ; Králová, Zuzana (advisor)
This theses is regarding a proposal of adaptation and extension of an object of an infant school in Pravenec. The object was built in 1963 and it was originally built to serve as a local infant school and creche. It served its original purpose until year 2000 and afterwards was used as a workshop of a textile factory. Since 2010 this object has not been utilised. Adaptation of object includes the alternation of its purpose. Object will be partially re-built and modified in order to be able to serve as a domestic building. There should be three separate housing units created, each with its own entrance. On first level there will be two individual accommodation units. On second level there will be a single apartment designed with an entrance through staircase. Adaptation also includes an overall isolation of the building, exchange of aperture blockage and a new flat roof as current condition of the object does not meet the quality standards.
Sportovní centrum "Fit Body"
Janíček, Vít ; Jelínek, Petr (referee) ; Vajkay, František (advisor)
Master thesis processes documentation for the realization of the new building of the multi-functional sporting centre. Object is designed as the two storey building with the external thermal insulation system ETICS. Object is designed according to the appropriate legislation. Object fulfills demands for the low-energy standard. Building is without cellar with the flat warm roof. Load bearing constructions of the floor ceilings are made out of prestressed concrete panels SPIROL. Load bearing construction of the hall roof is made of the glulam timber beams and purlins with the bracing.
Development of a new self-supporting insulation system with respect to dynamic stress
Machala, David ; Frajt, Daniel (referee) ; Drochytka, Rostislav (advisor)
This diploma thesis deals with suggestion of self-supporting insulating system that can be used for objects which insulating is more or less complicated. In this thesis are theoretically processed information about insulation systems while focus is on their structure, composition and principle of operation. Further, there is theoretically designed self-supporting insulating system which is practically built after theoretically composed testing for finding its basic properties. The most appropriate process of realization is formulated at the end after evaluation of the individual tests.