Název:
Integral Computation of Magnetic Field of Shielded Three-Phase Line
Překlad názvu:
Integrální výpočet magnetického pole stíněného trojfázového vedení
Autoři:
Karban, P. ; Doležel, Ivo ; Ulrych, B. Typ dokumentu: Příspěvky z konference Konference/Akce: AMTEE 2007, Pilsen (CZ), 2007-09-10 / 2007-09-12
Rok:
2007
Jazyk:
eng
Abstrakt: [eng][cze] The paper deals with numerical modeling of a three-phase harmonic-current carrying shielded line. In most similar cases, computation of magnetic field and other associated quantities is realized using the finite element method that is effective, reliable and the results obtained correspond to the physical reality. Nevertheless, the method may become problematic when particular subre-gions (conductors, insulation, shielding elements) are geometrically incommensurable, which is even the case of thin shielding shells. That is why the authors use the integral approach for modeling of the relevant effects. Presented is its basic continuous mathematical model that is solved numerically. The theoretical analysis is supplemented with a typical example.Článek se zabývá řešením magnetického pole v okolí stíněného trojfázového vedení. Řešení je provedeno integrální metodou. V článku je uveden matematický model, jehož numerické řešení je ilustrováno na příkladu.
Klíčová slova:
integral approach; numerical analysis; shielded system of conductors Číslo projektu: CEZ:AV0Z20570509 (CEP), GA102/07/0496 (CEP) Poskytovatel projektu: GA ČR Zdrojový dokument: Advanced Methods of the Theory of Electrical Engineering – AMTEE 2007, ISBN 978-80-7043-564-9 Poznámka: Související webová stránka: http://faraday.fel.zcu.cz/amtee/
Instituce: Ústav termomechaniky AV ČR
(web)
Informace o dostupnosti dokumentu:
Dokument je dostupný v příslušném ústavu Akademie věd ČR. Původní záznam: http://hdl.handle.net/11104/0149927