Název: Control Techniques of Grid Connected PWM Rectifiers under Unbalanced Input Voltage Conditions
Autoři: Bejvl, Martin ; Šimek, Petr ; Škramlík, Jiří ; Valouch, Viktor
Typ dokumentu: Příspěvky z konference
Konference/Akce: ELEN 2012, Prague (CZ), 2012-09-11 / 2012-09-12
Rok: 2012
Jazyk: eng
Abstrakt: Current-controlled voltage source converters are widely used in grid-connected applications,for example at ac drives with indirect frequency converters.The structure and parameters of the PLL are developed and proposed in order to cope with the grid containing both the positive and the negative sequence component, and minimize the wrong frequency transients during phase angle steps and also in the start-up stage. The DSC technique was realised. There is also necessary to compensate the negative sequence component in the grid voltage. The negative sequence component of the grid voltage causes ripple of the dc voltage in the intermediate circuit. Several sophisticated topologies of converter current controller were developed, simulated and tested for this purpose. Results of simulation and experimental tests are provided to evaluate different current control schemes and phase locked loop techniques.
Klíčová slova: current controller; DSC (Delayed Signal Cancellation); phase locked loop (PLL)
Číslo projektu: FR-TI1/330 (CEP)
Poskytovatel projektu: GA MPO
Zdrojový dokument: ELEN 2012, ISBN 978-80-01-05096-5

Instituce: Ústav termomechaniky AV ČR (web)
Informace o dostupnosti dokumentu: Dokument je dostupný v příslušném ústavu Akademie věd ČR.
Původní záznam: http://hdl.handle.net/11104/0211255

Trvalý odkaz NUŠL: http://www.nusl.cz/ntk/nusl-126811


Záznam je zařazen do těchto sbírek:
Věda a výzkum > AV ČR > Ústav termomechaniky
Konferenční materiály > Příspěvky z konference
 Záznam vytvořen dne 2012-11-02, naposledy upraven 2021-11-24.


Není přiložen dokument
  • Exportovat ve formátu DC, NUŠL, RIS
  • Sdílet