Název:
(Strept)avidin-biotin interactions at amalgam electrodes covered by thiol monolayer
Autoři:
Josypčuk, Bohdan ; Mareček, Vladimír ; Yosypchuk, O. Typ dokumentu: Příspěvky z konference Konference/Akce: Moderní elektrochemické metody /32./, Jetřichovice (CZ), 2012-05-21 / 2012-05-25
Rok:
2012
Jazyk:
eng
Abstrakt: Carboxylic group of 11-mercaptoundecanoic acid (MUA) can be used to creat a peptide bond with species containing amino group, e.g., peptides, and proteins. By the help of EDC-NHS technology, streptavidin or avidin was covalently bonded with MUA-monolayer at a silver solid amalgam electrode. Such prepared electrode was used for detecting biotin and biotinylated albumin in the supporting electrolyte (0.15 M NaCl, 0.05 M TRIS, pH 7.0). Electrochemical impendance spectroscopy was performed for the biosensor response monitored by impedance spectroscopy. Binding of biotin or biotinylated albumin with (strept)avidin a change in the resistance of the sensor in the concentration range of 0.5-20 μg mL-1. Electrochemical regeneration of the amalgam electrode permits simply to renew its surface and to create the new biosensor.
Klíčová slova:
amalgam electrodes; monolayer; voltammetry Číslo projektu: GAP206/11/1638 (CEP), GAP208/12/1645 (CEP), IAA400400806 (CEP) Poskytovatel projektu: GA ČR, GA ČR, GA AV ČR Zdrojový dokument: XXXII. Moderní elektrochemické metody. Sborník přednášek, ISBN 978-80-905221-0-7
Instituce: Ústav fyzikální chemie J. Heyrovského AV ČR
(web)
Informace o dostupnosti dokumentu:
Dokument je dostupný v příslušném ústavu Akademie věd ČR. Původní záznam: http://hdl.handle.net/11104/0007008