Original title:
CDF model of mixture gas flow in the vacuum column 12T-70102, revamp tower
Authors:
Říha, Zdeněk Document type: Research reports
Year:
2015
Language:
eng Abstract:
The report contains description of fluid flow for case with revamp tower of the column 12T -70102. Vapor flow was mainly calculated in the above mentioned geometry. In last iteration the liquid droplet (diameter 0,3mm) were injected into the geometry through the nozzle 12, see enclosure in the report. Introductory section of the enclosuere contains pictures with geometry and boundary conditions description, See figure G1. Then, slice plan follows, see figure G2. Next pictures show distribution of pressure and velocity on given slices. Pictures at the end of the enclosure show path-lines distribution and droplets particle traces distribution in the solved geometry.
Keywords:
CDF model; gas flow; vacuum column
Institution: Institute of Geonics AS ČR
(web)
Document availability information: Fulltext is available on demand via the digital repository of the Academy of Sciences. Original record: http://hdl.handle.net/11104/0253249