Abstrakt: The report contains description of fluid flow for case with revamp tower of the column 12T -70102. Vapor flow was mainly calculated in the above mentioned geometry. In last iteration the liquid droplet (diameter 0,3mm) were injected into the geometry through the nozzle 12, see enclosure in the report. Introductory section of the enclosuere contains pictures with geometry and boundary conditions description, See figure G1. Then, slice plan follows, see figure G2. Next pictures show distribution of pressure and velocity on given slices. Pictures at the end of the enclosure show path-lines distribution and droplets particle traces distribution in the solved geometry.