Original title: The flow of mixture vapors in the athmospheric column, comparison of new distributor and new tray
Authors: Říha, Zdeněk
Document type: Research reports
Year: 2014
Language: eng
Abstract: The description of CFD analysis and the description of mixture gas flow in the atmospheric column are listed in the report. This article builds on previous work [1]. There were calculated two cases with original distributor and with GT-OPTIFLOW distributor, see [1]. This article adds next two cases. The case with adjusted GT-OPTIFLOW distributor (enclosure 1) and adjusted GT-OPTIFLOW distributor with newly designed the chimney tray and new layout of the packing bed (enclosure 2). The flow area of the newly designed chimney tray is smaller than for previous design (5,36m2 vs. 6,89m2). New layout of the packing bed has smaller flow area (28,27m2 vs. 29,35m2) and higher pressure drop (129 Pa vs. 80Pa) in comparison with last design of the packing bed also used in [1].
Keywords: CFD analysis; mixture vapors; velocity density pressure

Institution: Institute of Geonics AS ČR (web)
Document availability information: Fulltext is available at the institute of the Academy of Sciences.
Original record: http://hdl.handle.net/11104/0243380

Permalink: http://www.nusl.cz/ntk/nusl-180573


The record appears in these collections:
Research > Institutes ASCR > Institute of Geonics
Reports > Research reports
 Record created 2015-01-26, last modified 2021-11-24


No fulltext
  • Export as DC, NUŠL, RIS
  • Share