Název: The flow of mixture vapors in the athmospheric column, comparison of new distributor and new tray
Autoři: Říha, Zdeněk
Typ dokumentu: Výzkumné zprávy
Rok: 2014
Jazyk: eng
Abstrakt: The description of CFD analysis and the description of mixture gas flow in the atmospheric column are listed in the report. This article builds on previous work [1]. There were calculated two cases with original distributor and with GT-OPTIFLOW distributor, see [1]. This article adds next two cases. The case with adjusted GT-OPTIFLOW distributor (enclosure 1) and adjusted GT-OPTIFLOW distributor with newly designed the chimney tray and new layout of the packing bed (enclosure 2). The flow area of the newly designed chimney tray is smaller than for previous design (5,36m2 vs. 6,89m2). New layout of the packing bed has smaller flow area (28,27m2 vs. 29,35m2) and higher pressure drop (129 Pa vs. 80Pa) in comparison with last design of the packing bed also used in [1].
Klíčová slova: CFD analysis; mixture vapors; velocity density pressure

Instituce: Ústav geoniky AV ČR (web)
Informace o dostupnosti dokumentu: Dokument je dostupný v příslušném ústavu Akademie věd ČR.
Původní záznam: http://hdl.handle.net/11104/0243380

Trvalý odkaz NUŠL: http://www.nusl.cz/ntk/nusl-180573


Záznam je zařazen do těchto sbírek:
Věda a výzkum > AV ČR > Ústav geoniky
Zprávy > Výzkumné zprávy
 Záznam vytvořen dne 2015-01-26, naposledy upraven 2021-11-24.


Není přiložen dokument
  • Exportovat ve formátu DC, NUŠL, RIS
  • Sdílet