National Repository of Grey Literature 18 records found  previous11 - 18  jump to record: Search took 0.00 seconds. 
Determination of Te(IV) by photochemical generation of volatile compounds with atomic spectrometric detection
Ruxová, Helena ; Hraníček, Jakub (advisor) ; Šíma, Jan (referee)
This thesis deals with the development of a method suitable for determination Te(IV) by UV-photochemical generation of volatile compounds (UV-PVG) in liquid samples. Atomic absorption spectrometry (AAS) and atomic fluorescent spectrometry (AFS) were used as detection methods. The basis of the apparatus for UV-PVG was a mercury lamp wrapped by PTFE capillary. Firstly, the experimental parameters were optimized for both methods. The optimized parameters were the type, concentration, pH and flow rate of the reaction medium, the length of the PTFE reaction coil, carrier gas flow rate (argon), supportive gas flow rate (hydrogen) and atomization temperature. The figures of merit with both detection methods were determined and compared after the method was optimized. Detection limits achieved for these two detection methods were 6,0 µg dm-3 for AFS and 1,50 µg dm-3 for AAS. Performed interference study confirmed a significant effect of many cations of transition metals and hydride forming elements on tellurium determination. The influence of nitric acid in the sample was studied separately. The suitability of the method for tellurium determination was confirmed by using a spiked certified reference material.
Hydride generation of tellurium for atomic absorption spectrometry
Bufková, Kateřina ; Musil, Stanislav (advisor) ; Matoušek, Tomáš (referee)
This master's thesis deals with optimization of conditions of chemical hydride generation of tellurium and conditions of its atomization, specifically in three types of atomizers - in a diffusion flame (DF), in a heated multiple microflame quartz tube atomizer (MMQTA) and in a dielectric barrier discharge (DBD) atomizer. Tellurium hydride was generated in a flow injection arrangement and a high-resolution continuum source atomic absorption spectrometer was used for detection. As hydride generation can be only done from tetravalent species of tellurium, at first a simple procedure of pre-reduction of hexavalent species of tellurium by heating a standard in hydrochloric acid at 6 mol dm-3 was verified. Further, conditions of chemical generation were optimized with a goal to achieve as high generation efficiency as possible, namely, concentration of hydrochloric acid and sodium tetrahydroborate, volume of the reaction coil and a flow rate of carrier gas. Subsequently, conditions of atomization of tellurium hydride were examined with chosen optimal generation conditions. In the case of DF, it was an amount of hydrogen in the flame, a total flow rate of gases and observation height. In the case of MMQTA, temperature of the atomizer, a flow rate of carrier gas and a flow rate of air or oxygen needed for...
Electrochemical generation of tellurium and bismuth hydrides for AAS
Resslerová, Tina ; Hraníček, Jakub (advisor) ; Šíma, Jan (referee)
Tellurium and bismuth are non-biogenous elements, which can be accumulated in human body. The aim of this work is focused on the determination of these elements by the electrochemical hydride generation with non-membrane electrolytic cell with quartz tube - atomic absorption spectrometry. The first step of the work was to optimize parameters for the continuous setup measurements and to obtain its figures of merit. After this, the arrangement with most suitable conditions for determination of these elements was converted to the flow injection setup (FIA) and all experimental parameters were again optimized and its figures of merit were obtained. The conditions of hydride generation were studied for platinum, lead and silver cathodes with hydrochloric and sulphuric acids and their sodium salts as electrolytes. The optimizations of the FIA setup were performed on platinum cathode in hydrochloric acid for bismuth and on lead cathode in sulphuric acid for tellurium. The limit of detection achieved for the generation of tellurium hydride was 1.1 ppm with a linear range up to 20 ppm; for the bismuth hydride the limit of detection was 9.5 ppm and limit of linearity 50 ppm. Keywords Bismuth, tellurium, electrochemical hydride generation, atomic absorption spectroscopy, flow injection analysis
Electrochemical generation of tellurium hydride for AAS
Resslerová, Tina ; Hraníček, Jakub (advisor) ; Červený, Václav (referee)
Tellurium is non-biological element which is not common in the earth. It can be accumulated in a body and cause many health problems. In this work, tellurium is determined by the electrochemical hydride generation technique coupled with atomic absorption spectrometry with quartz tube atomizer. In the first part of this work, various relevant parameters of tellurium hydride generation were optimized to achieve high sensitivity. Under the optimal working parameters, calibration dependences and other basic characteristics were measured. Finally, the influence of oxygen added on the different places of set up was carried out. Optimized parameters were flow rate of the carrier gas, generation current, flow rate and concentration of electrolytes. Optimizations were measured for two different catholytes: hydrochloric and sulfuric acid, with similar results. In addition the calibration was measured with orthophosporic acid. Further experiments with oxygen were performed for sulfuric acid as the catholyte. Influence of oxygen on the baseline and the process of determination were performed, for both continuous and limited time addition.
Study of CdTe sensor properties
Vašíček, Martin ; Holcman, Vladimír (referee) ; Grmela, Lubomír (advisor)
This Bachelor Thesis is focused on studies of CdTe detector characteristics. It is to describe the analysis of transport and noise characteristics of CdTe samples at different temperatures. Evaluation of our results proves that CdTe junction behaves like an antiseries connection of a pair of diodes. The courses of VA characteristics are noted for linear or slightly exponential growth. When temperature is growing , conductivity of the samples is growing too. Our measurements demonstrated difference in conductivity of samples tested at the same temperature. It is also obvious that within very low range of frequencies the factor of noise 1/f is dominating. From 10Hz frequency the effect of thermal noise prevails.
Multicomponental Preconcentration of As, Sb, Se and Te on Modified Silica, Their Determination by ICP-AES (ICP-MS) and Application for Waters
Urbánková, Kristýna ; Řehůřková, Irena (referee) ; Kanický, Viktor (referee) ; Ventura, Karel (referee) ; Sommer, Lumír (advisor)
The determination of inorganic speciations of arsenic, antimony, selenium and tellurium in natural waters demands often separation and preconcentration. Solid phase extraction is a very effective method for these purposes. In this paper the separation and preconcentration of these microelements is realised on the basis of modified silica Separon SGX C18, SGX C8, SGX CN, SGX NH2, SGX Phenyl and strongly basic anion Exchanger SGX AX. The sorption was provided in the presence of cationic surfactants such as benzyldimethyl dodecylammonium bromide (Ajatin), benzyldimethyltetradecylammonium chloride (Zephyramine), 1-ethoxycarbonylpentadecyltrimetrhylammonium bromide (Septonex) and selected complexing agents 4-(2-pyridylazo)resorcinol (PAR), 8-hydroxyquinoline-5-sulphonic acide (8-HQS), 1,2-dihydroxybenzene (PYR), amonium 1-pyrrolidinecarbodithioate (APDC), sodium diethyldithiocarbamate (DTC) or thiourea(Thur). The interactions of the formed ion associate with the sorbent shows a complicated character which has not been cleared as yet. The previous conditioning of the sorbent plays an outstanding role. Thus, the sorption efficiency was studied in the presence and absence of surfactant and of selected organic complexing agents. Moreover, the influence of pH of the sorbed solution as well as the speed and the volume of the solution running through the sorbent and the type and volume of the eluent on the resulting sorption efficiency was evaluated. The sorption was successfully carried out from 50-1000 ml of solution which allows the 100 fold increase of the preconcentration factor and the determination of the microelements in g.l-1 instead of mg.l-1 by using the common ICP-AES. The influence of macroelements occurring in waters as well as B, Be, Bi, Cd, Co, Cr, Cu, Mn, Mo, Ni, Pb, Sr, Ti, V and Zn in comparable concentrations involve less than 5% error. After the quantitative elution of microelements, the organic solvents were evaporated under IR lamps prior to the determination by ICP-AES and |ICP-MS. The conditions for the direct determination of arsenic, antimony, selenium and tellurium in g.l-1 with ICP-MS were also described in detail in the absence and presence of internal standards Ge and Bi. However, even in this case the preconcentration on silica in the presence of surfactant and selected organic complexants was also tested. When the sorption was followed from 500 ml a 50 fold enrichment factor is reached and the sensitivity for the microelements is improved. The direct determination and the sorption of microelements were applied on synthetic and real waters (dirinking, surface, mineral and sea waters). Instrumental and practical detection limits for various water samples were evaluated according to IUPAC. The results from 1000 ml solution of real waters after sorption on modified silica and the final determination of microelements with ICP-AES were compared with those from ICP-MS without sorption using the method of standards addition in the presence of suitable internal standards. By comparison of results for synthetic and real water samples the error of the determination of microelements was evaluated.
Analysis of noise characteristics of radioactive emission detectors
Šik, Ondřej ; Pfeifer, Václav (referee) ; Andreev, Alexey (advisor)
The main goal of this Master’s thesis is to describe relationship between low frequency noise spectral characteristics of Cadmium-Telluride radiation detectors depending on applied voltage and detectors reaction to illumination of various wavelengths. Also, the reaction and influence of higher operating temperatures were investigated. The noise measurements shown that the dominant noise type at low frequencies is the 1/f noise. Several samples with different resistivity were tested. By comparing results, we are able to estimate the quality of detectors and their sensibility to illumination and higher operating temperatures. We have found that all the studied CdTe detectors are sensitive to one particular wavelength of 548nm. Resulting data were processed by EasyPlot program that provided graphical representation of spectral noise characteristics. All measured characteristics of tested samples are compared and it’s estimated the similarity between the samples.
Signal analysis of transport and stochastic processes of emission detectors
Míšek, David ; Tofel, Pavel (referee) ; Andreev, Alexey (advisor)
This Diploma thesis deals with properties of CdTe detectors. This material is ranked among optical sensitive group. This thesis can be thematically divided into two basic parts. The first part describes properties of both elements and the chemical adduct. Selected properties show perfections of the material, which are specializing it to optical area of application. The end of this part contains description of contact metal-semiconductor. This problem is important to comprehension principle the material contact. In second part there were making many measurements. For more accurately compare were first measurements doing without light and then with light. During making measurement was changed wave length and temperature of sample. Key factors were Volt-Ampere characteristics and resistance result with changed temperature and wave length impact to the sample. For better accuracy measurements were done many times. All of data from measurement were cultivate by PC Easyplot programme.

National Repository of Grey Literature : 18 records found   previous11 - 18  jump to record:
Interested in being notified about new results for this query?
Subscribe to the RSS feed.