National Repository of Grey Literature 282 records found  1 - 10nextend  jump to record: Search took 0.02 seconds. 
Steel structure of indoor pool
Lengyel, Barbara ; Pešek, Ondřej (referee) ; Horáček, Martin (advisor)
The content of this bachelor's thesis is the design and the assessment of the loadbearing steel structure of an indoor pool. Ground plan dimensions are 30×84 m and the height of the structure is 14 m. The main supporting system is composed of 15 main trusses in 6 metre distance. The main truss is formed by a truss girder in the shape of a wave, which is on one side pinned on steel column and on the other side is pinned on concrete column. Main columns are fixed in main course and pin supported in longtudinal course. Frontal columns are pin supported in both courses. Main trusses are connected by purlins and girts. Spatial rigidity of the structure is ensured by system of longitudinal and sway bracings.
Steel Structure of Pool Building
Novotný, David ; Karmazínová, Marcela (referee) ; Melcher, Jindřich (advisor)
This bachelor thesis focuses on the design and stress analysis of the steel structure of pool building in Brno. It also includes the assessment of the main load-bearing construction elements and of the details of selected connections. The thesis also contains the design documentation of the building.
Airport terminal
Mika, Václav ; Pešek, Ondřej (referee) ; Horáček, Martin (advisor)
The diploma thesis deals with design and structural assesment of the steel airport terminal in Prag-Ruzyne. The project is designed in two options. The dimensions of the rectagular floor plan are 79,3 x 98,65 m. The height of the building in highest point is 21,5 m. The airport terminal contains 9 main frames spaced by 9 m. The cladding of the roof and the side walls is designed by sendwich panels. The face wall is made by glass facade system.
The roof structure of the industrial hall in Kyjov
Nosková, Nela ; Pilgr, Milan (referee) ; Šmak, Milan (advisor)
The Bachelor´s thesis describes design and static assessment of the main roof structure supporting elements of the roof structure of the industrial hall in Kyjov. The hall is designed from timber. The aisle is rectangular floor plan 17,0 x 40,0 m. The main bearing structure causes as a frame truss supported by columns. Solid frame is made from solid timber C24. Purlin is designed from solid timber C24. The static calculation also includes fire resistance reports of single elements. Static analysis has been accomplished by student version of the SCIA Engineer 2012 software.
Assembly hall
Beran, Miroslav ; Pilgr, Milan (referee) ; Barnat, Jan (advisor)
The diploma thesis deals with the design and assessment of the steel supporting structure of the production hall. The transverse dimension of the hall is 21,00 m, the longitudinal dimension is 70,00 m, the height of the hall is 17,56 m. S355 steel is used as the main supporting material. The supporting part of the hall consists of columns on which is placed a truss and two crane tracks at two height levels. Three different types of purlins and pillars are considered in the design of the steel structure. For the selected variant, a static calculation of the main bearing elements, including selected details, is drawn up and drawings are drawn up.
Analysis of structure using stages calculation
Čejková, Eva ; Nevařil, Aleš (referee) ; Vlk, Zbyněk (advisor)
Bachelor thesis deals with the roof structure, its static assessment and analysis phases of construction. It is a roofing tennis hall parabolic trusses, which are formed from steel. In the hall there are three tennis courts and space for an auditorium for spectators. The entire structure and calculations are processed in a static software RFEM by the Dlubal. Only the load cases are calculated manually.
Housing for seniors
Vrbický, Josef ; Donaťák, Vladislav (referee) ; Donaťáková, Dagmar (advisor)
The subject of the diploma thesis is the design of a new building of a free-standing building for housing for the elderly, in the form of project documentation for the construction. The building is designed brick with monolithic reinforced concrete ceilings. Perimeter masonry is designed from ceramic brick blocks th. 300 mm supplemented by contact insulation system ETICS th. 200 mm, which will be provided with silicone plaster with a grain size of 1.5 mm. The internal load-bearing masonry is designed from acoustic ceramic brick blocks of thickness 250 and 300 mm. The partitions are designed from acoustic partitions. The ceilings are designed with a heavy floating floor with excellent acoustic properties. The roof above the two-storey part is designed as a single-skin flat with extensive greenery. Above the three-storey part is a hipped roof made of lattice trusses and sheet metal roofing. The windows are designed with plastic insulating triple glazing. The balcony railing is designed for aluminum with safety glass filling. The building is heated by a gas boiler and controlled ventilation is designed throughout the building using a central recuperation.
Steel Load-bearing Structure of a Car Showroom and Repair Centre
Thomanková, Lucie ; Buchta, Stanislav (referee) ; Bajer, Miroslav (advisor)
Diploma thesis includes design and examination of steel load-carrying structure. Construction includes car deal warehouse and car repair shop with extension for car varnishing. Car deal warehouse has ground dimensions 22 x 30 m and total high 10 m. Main frame is composed of Vierendeel trusses with arc shape. Car repair shop has ground dimensions 20 x 30 m and total high 10 m. Main frame is composed of truss girders and web-plate columns. Frame extension has ground dimension 20 x 10 m and total high 6,4 m. Cladding is composed of sandwich panels. Store´s gable wall and a part of the roof are glass. Climatic load is intended for locality Ostrava.
Load carrying structure of a riding hall
Patrný, Jan ; Straka, Bohumil (referee) ; Sýkora, Karel (advisor)
The aim of this thesis is the design and assessment of the load carrying structure of a riding hall in Třebechovice pod Orebem. It is a rectangular hall with dimension of 36 meters x 72 meters with a gabled roof that will be utilized for dressage and equestrian competitions. Hall dimension is determined by the riding area 25 meters x 60 meters,by the safety clearances and grandstand for spectators. The load carrying structure is made up of thirteen crosslinks by six meters of solid-columns and lattice trusses connected by purlins. The spatial rigidity of the structure is ensured by the bracings system.
Steel load-bearing structure of an industrial hall
Jaroš, Jakub ; Pešek, Ondřej (referee) ; Balázs, Ivan (advisor)
The bachelor´s thesis contains design of one-aisle industrial hall with span of 24 m, length of 72 m and height of the holder of craneway 9 m. In hall there are two cranes, first one with load capacity of 32/8 t and second one with load capacity of 12,5 t. The roof structure is designed as a system of truss girders and truss purlins. Spatial rigidity of the structure is secured by bracing. Main structural material is steel S235 JR+AR ČSN EN 10025-2. Drawings contain flor wiew and sections of hall and manufacturing drawings of truss.

National Repository of Grey Literature : 282 records found   1 - 10nextend  jump to record: