National Repository of Grey Literature 5 records found  Search took 0.00 seconds. 
Active Angular Alignment of Gauge Blocks in Double-Ended Interferometers
Buchta, Zdeněk
This paper presents a method implemented in a system for automatic contactless calibration of gauge blocks designed at ISI ASCR. The system combines low-coherence interferometry and laser interferometry, where the first identifies the gauge block sides position and the second one measures the gauge block length itself. A crucial part of the system is the algorithm for gauge block alignment to the measuring beam which is able to compensate the gauge block lateral and longitudinal tilt up to 0.141 mrad. The algorithm is also important for the gauge block position monitoring during its length measurement.
Multidimensional interferometric measuremenr system for AFM microscopy - national standard for nanometrology
Hrabina, Jan
We present the design and performance characteristics of 6-axis interferometric measurement system for local probe microscopy. Described measurement tool was developed in colaboration with the Czech Metrological Institute in Brno and it is intended to solve as a national nanometrological standard. The system in based on a commercial nanopositioning sample table controlled by piezoelectric transducers, a metrological frame and a laser interferometric setup for dimensional measurements in six degrees of freedom.
Nanopositioning with detection of a standing wave
Holá, Miroslava ; Hrabina, Jan ; Číp, Ondřej ; Fejfar, A. ; Stuchlík, J. ; Kočka, J. ; Oulehla, Jindřich ; Lazar, Josef
A measuring technique is intended for displacement and position sensing over a limited range with detection of standing-wave pattern inside of a passive Fabry-Perot cavity. In this concept we consider locking of the laser optical frequency and the length of the Fabry-Perot cavity in resonance. Fixing the length of the cavity to e.g. a highly stable mechanical reference allows stabilizing wavelength of the laser in air and thus to eliminate especially the faster fluctuations of refractive index of air due to air flow and inhomogeneity. Detection of the interference maxima and minima within the Fabry-Perot cavity along the beam axis has been tested and proven with a low loss transparent photodetector with very low reflectivity. The transparent photodetector is based on a thin polycrystalline silicon layer. Reduction of losses was achieved thanks to a design as an optimized set of interference layers acting as an antireflection coating. The principle is demonstrated on an experimental setup.
Interferometric coordinates measurement sytem for local probe microscopy nanometrology
Hrabina, Jan ; Lazar, Josef ; Klepetek, P. ; Číp, Ondřej ; Čížek, Martin ; Holá, Miroslava ; Šerý, Mojmír
We present an overview of new approaches to the design of nanometrology measuring system with a focus on methodology of nanometrology interferometric techniques and associated problems. The design and development of a nanopositioning setup with interferometric multiaxis monitoring and control involved for scanning probe microscopy techniques (primarily atomic force microscopy, AFM) for detection of the sample profile is presented. Coordinate position sensing allows upgrading the imaging microscope techniques up to quantified measuring. Especially imaging techniques in the micro- and nanoworld overcoming the barrier of resolution given by the wavelength of visible light are a suitable basis for design of measuring systems with the best resolution possible. The system is being developed in cooperation with the Czech metrology institute and it is intended to operate as a national nanometrology standard combining local probe microscopy techniques and sample position control with traceability to the primary standard of length.
Nanometrology coordinate measurement machines uncertainties caused by frequency fluctuations of the laser
Hrabina, Jan ; Lazar, Josef ; Číp, Ondřej
One of considerable sources of displacement measurement uncertainty in nanometrology systems such as multidimensional interferometric positioning for local probe microscopy is the influence of amplitude and especially frequency noise of a laser source which powers the interferometers. We investigated the noise properties of several laser sources suitable for interferometry for micro- and nano-CMMs (coordinate measurement machines) and compared the results with the aim to find the best option. The influences of amplitude and frequency fluctuations were compared together with the noise and uncertainty contributions of other components of the whole measuring system. Frequency noise of investigated laser sources was measured by two approaches – at first with the help of frequency discriminator (Fabry-Perot resonator) converting the frequency (phase) noise into amplitude one and then directly through the measurement of displacement noise at the output of the interferometer fringe detection and position evaluation. Both frequency noise measurements and amplitude noise measurements were done simultaneously through fast and high dynamic range synchronous sampling to have the possibility to separate the frequency noise and to compare the recorded results.

Interested in being notified about new results for this query?
Subscribe to the RSS feed.