Indoor Monitoring System For Well-being
Kočka, Jakub ; Arm, Jakub
The work address the indoor air quality monitoringenabling to monitor the well-being and comfort of occupants.A monitoring system is able to measure room temperature,humidity, barometric pressure, CO2, luminosity, and dust pollutionusing chip sensors. The measurement devices are connectedwirelessly via ZigBee 3.0 technology enabling mesh networktopology and the measured data is collected into a database.The data will be then processed and presented using a cloudapplication enabling advanced control and alarm management,when a value exceeds the health limits. The measurement systemcomprises of measurement devices and a gateway. The measurementdevice is designed as a sandwich architecture comprisingsensor and communication module. The created sensor moduleis interfaced with Adafruit Feather interface in order to useany available Adafruit SoC kit as the communication module.The conducted results also suggest that ESP32-H2, which isnow in pre-production phase, operates as ZigBee 3.0 SoC inan embedded device.
Výzkum systémů pro zajištění kvality prostředí v kabině automobilu
Šíp, Jan ; Kavička, František (oponent) ; Volavý, Jaroslav (oponent) ; Lízal, František (vedoucí práce)
Udržováním kvality vnitřního prostředí, zejména tepelného komfortu a vnitřní kvality vzduchu v kabinách automobilů, předcházíme dopravním nehodám. Tepelný komfort může mít vliv na kognitivní funkce důležité zejména pro řidiče. Mezi ně patří koncentrace, pozornost či rychlost rozhodování. Je známo, že nesprávná teplota v kabině automobilu patří mezi nejčastější faktory způsobující dopravní nehody. Jedním z faktorů vnitřní kvality prostředí je vnitřní kvalita vzduchu. Ta je vlivem silničního provozu negativně ovlivněna výfukovými plyny a částicemi z otěru pneumatik, které se během větrání dostávají do prostoru kabiny. Tomu lze předejít využitím systému recirkulace a opětovné filtrace vzduchu, u kterého se nepřivádí venkovní vzduch, ale jedná se o uzavřený oběh. Nevýhodou systému recirkulace jsou vyšší koncentrace CO2, což může způsobovat nadměrnou únavu. Dizertační práce se zabývá vlivem různých systémů větrání na vnitřní kvalitu prostředí, tj. tepelný komfort a vnitřní kvalitu vzduchu. Dílčím faktorem tepelného komfortu je rychlost proudění vzduchu, která byla v rámci této práce zkoumaná v prostoru za vyústkou. Pro měření proudového pole za automobilovou vyústkou byla použita metoda termoanemometrie. Experimentální výsledky byly doplněny o CFD analýzu. Tepelný komfort v kabině automobilu byl stanoven pomocí CFD, a to pro tři různé systémy větrání (směšovací, podlahové a stropní). Kromě klasického uspořádání interiéru byl předmětem zájmu i flexibilní interiér, u kterého jsou přední sedadla otočeny proti směru jízdy. Kvalita vzduchu pro jednotlivé systémy větrání byla posuzovaná taktéž na základě CFD, konkrétně byl využit index stáří vzduchu. Výzkum proudového pole potvrdil platnost využití empirického vztahu dle Rajaratnama pro určení poklesu osové rychlosti na reálnou automobilovou vyústku. Dále byla ověřena přesnost metod modelování turbulence Reynolds-averaged Navier–Stokes a Large Eddy Simulation, a to na základě všech sledovaných kritérií (úhly směrování, pokles osové rychlosti, rychlostní profily a porovnání intenzity turbulence). Studie tepelného komfortu poukazují na vhodnost použití stropního systému větrání pro letní podmínky, naopak v zimních podmínkách lze doporučit přívod vzduchu podlahovými vyústkami. Z pohledu indexu stáří vzduchu je nejvhodnější stropní větrání pro zimní podmínky. V letních podmínkách jsou hodnoty indexu stáří vzduchu u jednotlivých konceptů větrání velice podobné pro oba typy interiéru.
Effective management of building technologies with a focus on measuring humidity and CO2 concentration
Bučko, Ondrej ; Bátora, Branislav (oponent) ; Janík, Daniel (vedoucí práce)
The diploma thesis deals with automated measurement of humidity and CO2 concentration inside buildings. Results of this measurement form the input parameters for the effective management of technologies reducing the energy performance of buildings. In the introduction, the issue of indoor air quality of buildings and indicators characterizing this quality are approached. The technical part of the thesis consists of making a measuring device which contains two prototype sensors provided by Teco Inc. with online access to measured data. The measurement of relative humidity, CO2 concentration and temperature in the interior of the building with the made device is compared with commercially available devices for measuring selected parameters. For unambiguous interpretation of online data, the virtual machine with an online database is configured for the created measuring device. The possibilities of using the prepared measuring device to achieve a reduction in the energy performance of buildings are discussed in the final part.
Systémy energeticky úsporných budov
Červený, Miloš ; Horká, Lucie (oponent) ; Počinková, Marcela (vedoucí práce)
První část diplomové práce se věnuje problematice vnitřního klimatu ve školských budovách. Druhá část se zabývá návrhem otopné soustavy v přístavbě základní školy včetně návrhu zdroje a rekonstrukci zdroje pro stávající budovu ve variantním řešení. V poslední části se práce věnuje experimentálnímu měření kvality vnitřního vzduchu ve třídě základní školy.
Indoor Particles of Outdoor Origin in Depositories.
Mašková, Ludmila ; Smolík, Jiří ; Trávníčková, Tereza ; Havlica, Jaromír ; Ondráček, Jakub ; Ondráčková, Lucie
Pollution in indoor environment can cause irreversible degradation of materials stored there. The air quality in depositories housed in historical buildings depends mainly on outdoor pollution infiltrated through the building envelope. There are several strategies to control the indoor air pollution. However, most of them including reconstruction, which is problematic in historical monuments. Thus detailed information about indoor air quality and factors influencing it is needed.
Plný tet: SKMBT_C22019110512070 - Stáhnout plný textPDF
Plný text: content.csg - Stáhnout plný textPDF
Epidemiologická situace v lékárně
SCHNEIDEROVÁ, Kateřina
Mezi nejčastější onemocnění patří respirační nákazy přenášené vzdušnou cestou. Postihují děti i dospělé, potenciálně nebezpečné však mohou být pro osoby oslabené primárním onemocněním nebo poruchou imunity. Patogeny bývají do okolí vylučovány nemocným člověkem pomocí kapének či biologického aerosolu při kašlání, kýchání nebo mluvení. Tyto způsoby přenosu představují riziko v šíření nozokomiálních nákaz ve zdravotnickém zařízení. Cílem bakalářské práce bylo zjistit výši mikrobiálního znečištění ovzduší vnitřního prostředí a vyhodnotit případný negativní vliv bakteriální kontaminace na zdraví pacientů přítomných v lékárně. Laboratorní část práce byla zaměřena na odběr, zpracování a identifikaci infekčního agens šířeného vzdušnou cestou ve zdravotnickém zařízení (lékárně) v období 5/2018-2/2019. K odběru vzorku byla použita metoda pasivního sběru (plotnová sedimentační metoda). Její podstatou je usazování mikroorganismů přítomných ve vzduchu na krevní agar v Petriho misce. Na výši mikrobiálního znečištění vnitřního ovzduší byl posuzován také vliv teploty a vlhkosti vzduchu v lékárně a počet osob přítomných v době odběru vzorku. Dle Vyhlášky č. 6/2003 Sb., která stanovuje hygienické limity biologických ukazatelů pro vnitřní prostředí pobytových místností ve zdravotnickém zařízení, je maximální hranice 500 CFU/m3 (CFU je jednotka používaná k odhadu počtu životaschopných bakterií). Této hranice nebylo ve zkoumaném období dosaženo. Naměřené hodnoty dokázaly, že teplota, vlhkost a počet CFU/miska mají mezi sebou určitou mírnou pozitivní závislost. Porovnáním počtu pacientů a počtu CFU/misku se prokázalo, že tyto dvě veličiny nemají vzájemnou výraznou korelaci. Co se týče zastoupení jednotlivých skupin identifikovaných mikroorganismů ve vzorcích, převažující podíly má většinou skupina G+ Staphylococcus spp., která často tvoří více než 50 % mikroorganismů ve vzorku, někde dokonce až 75 %. Následují G- tyčky, jejichž podíl tvoří až 46 %, dále poté G+ diplokoky a tetrakoky, jejichž podíl dosahuje až 43 %. Z hledaných patogenů byl potvrzen výskyt Staphylococcus aureus a Streptococcus pyogenes. Výsledky bakalářské práce nepotvrdily překročení limitu mikrobiálního znečištění ovzduší v lékárně ani významný výskyt původců bakteriálních respiračních nákaz. Lze tedy považovat vnitřní ovzduší v lékárně z hlediska možnosti bakteriální nákazy za málo rizikové.
Charakteristika ovzduší vnitřních prostor zdravotnických zařízení
Hladíková, Dita ; Braniš, Martin (vedoucí práce) ; Holcátová, Ivana (oponent)
Nemocnice a zdravotnická zařízení jsou velice specifická prostředí, která vyžadují kontrolu kvality vnitřního ovzduší. Lidé, kteří navštěvují zdravotnická zařízení, bývají díky oslabenému imunitnímu systému na kvalitu ovzduší velice citliví. Zhoršená kvalita vnitřního ovzduší zdravotnických zařízení může mít nepříznivý vliv na pracovní výkon personálu zařízení, kdy případná pochybení z tohoto důvodu mohou mít velmi vážné následky. Podstatou diplomové práce je zhodnocení hlavních složek vnitřního mikroklimatu (teplota a relativní vlhkost vzduchu) a koncentrace oxidu uhličitého v prostředí vybraných zdravotnických zařízení v České republice a následné srovnání s právními předpisy, určenými pro tento typ prostředí. Měření probíhalo ve dvou nemocničních zařízeních a devíti soukromých lékařských ordinacích od prosince 2011 do března 2013. Z výsledků vyplynulo, že hodnoty mikroklimatických podmínek a koncentrace oxidu uhličitého v prostředí lůžkových pokojů pacientů byly v chladné a teplé části roku rozdílné. V zimní části se s požadavky právních předpisů nejvíce rozcházela relativní vlhkost vzduchu, zatímco během letního období byly zjištěny disproporce naměřených hodnot teploty vzduchu lůžkových pokojů. Na koncentraci oxidu uhličitého měla vliv velikost pokojů míra jejich obsazenosti. Kvalita ovzduší operačního...
Větrání budov s téměř nulovou spotřebou energie
Fojtík, Pavel ; Horká, Lucie (oponent) ; Hirš, Jiří (vedoucí práce)
Diplomová práce se zabývá systémy větrání v domech s téměř nulovou spotřebou energie. Práce je zaměřena především na kvalitu vnitřního prostředí a skládá se ze tří částí. První je teoretická část, kde jsou uvedeny právní předpisy a vyhlášky stanovující požadavky na nulové stavby, dále jsou zde popsány faktory ovlivňující kvalitu vzduchu v interiéru a přestaveny navrhované systémy. Ve druhé části se zabývám produkcí a transportem částic ve vnitřním prostředí budov a to přímo nZEB budově. Závěrečná část je zaměřena na návrh komunitního centra Skála, nové budovy která by měla splňovat nZEB standart, pro městskou část Nový Lískovec.