National Repository of Grey Literature 25,326 records found  beginprevious21 - 30nextend  jump to record: Search took 1.02 seconds. 

The use of biomass ash
Ochecová, Pavla ; Tlustoš, Pavel (advisor) ; Radim, Radim (referee)
One of the most frequently used sources of renewable energy is biomass, mainly wood biomass. Incineration is the most common technology utilizing the energy from biomass to produce heat. A byproduct of these technologies is ash, whose composition depends on the feedstock composition and the incineration technologies. Due to the high content of valuable nutrients in ash, one of the suitable option for ash utilization seems to be application into agricultural or forestry land. Therefore, it is necessary to test response of soils and plants and look for the most suitable combination of soil additive (biomass ash), and plants. Experimental part of PhD thesis was divided into the incubation experiment and the vegetation pot experiments. The incubation experiment: The efficiency of ash addition at two application rates was tested for nutrients enrichment in different soils within period of 56 days. The vegetation pot experiments: The two plants Triticum aestivum L: (three-year experiment) and Lolium perenne L. (one-year experiment) were planted in the 5L pots. Soils were treated with ash or ash combinated by superphoshate and flue gas desulfurization gypsum. For both plants, we evaluated the plant growth, biomass production and content of macro, micro and toxic elements in the biomass and in the soils.

Comparison of the Views and Attitudes of Pupils at Secondary Vocational Schools in the Field of Substance Abuse
Mazánková, Michaela ; Jirsáková, Jitka (advisor) ; Miroslava, Miroslava (referee)
Bachelor thesis entitled Comparison of the views and attitudes of pupils at secondary vocational schools in the field of substance abuse deals with a comparison of opinions and attitudes of pupils at secondary schools and vocational schools Obchodní akademie a Hotelová škola Havlíčkův Brod. The first part is devoted to general characteristics of risky behavior, causes of its origin, different types and prevention of risk behaviors . Analytical part is devoted to evaluation of the questionnaire and the results are compared opinions and attitudes of students of graduation schools and vocational schools, and point to the simultaneous occurrence of risk behavior studied in high school. Based on data evaluation are at the end of the work proposed specific preventive measures specifically for students of graduation schools and vocational schools.

Cooperation of high schools with external contractors in preparing school educational programs
Tulach, David ; Lačev, Alek (advisor) ; Hochel, Matej (referee)
This thesis, Cooperation of high schools with external contractors in preparing school educational programs, deals with the question whether it would be possible and beneficial for high schools to cooperate with companies on the preparation or modification of their educational programs, with the goal of improving the quality of education. After initial contributions from experts who provided negative replies to this question, the view was focused on the root of the issue - what are the historical pillars of public schools and pedagogy, what does science say about learning and teaching, how pedagogy reacts to the crisis of science. After comparing literal sources and results from interview with the experts, in combination with a trace and activity analysis, a theory was established that public education is reaching a point of crisis, has not changed in its essence since its beginning and that the best solution might be the establishment of alternative educational institutions.

Single particle analysis of size-segregated aerosol in Prague city center
Marvanová, S. ; Skoupý, Radim ; Kulich, P. ; Bendl, J. ; Hovorka, J. ; Machala, M.
Particulate matter (PM) is omnipresent pollutant in the ambient air known to cause cardiovascular and respiratory diseases (WHO 2004). Recently, outdoor air pollution and particulate matter in outdoor air pollution were classified as carcinogenic to humans, Group 1 (IARC 2015). Especially, ambient PM of aerodynamic diameter < 100 nm, ultrafine particles, appears to be of great importance due to its high specific surface area and high number concentration (Hughes et al. 1998). Ultrafine particles also easily enter and are being transferred in organisms, and interact with cells and subcellular components (Oberdorster et al. 2005). As the evidence of ultrafine PM significance increased, size-fractionated PMs sampled by various cascade impactors have been employed into the toxicological studies on cell cultures or isolated cells, using the organic extracts of size-fractionated PMs (Topinka et al. 2013, Topinka et al. 2015) or directly the size-fractionated particles (Becker et al. 2003, Ramgolam et al. 2009, Reibman et al. 2002, Loxham et al. 2013, Jalava et al. 2006, Thomson et al. 2015, Jalava et al. 2015). The aim of this study was to evaluate shape and composition of size-segregated aerosol particles, sampled by high volume cascade impactor, using electron microscopy and energy dispersive X-ray spectroscopy (EDX).

Diamond coated AlGaN/GaN high electron mobility transistors - effect of deposition process on gate electrode
Vanko, G. ; Ižák, Tibor ; Babchenko, O. ; Kromka, Alexander
We studied the influence of the diamond deposition on the degradation of Schottky gate electrodes (i.e. Ir or IrO2) and on the electrical characteristics of AlGaN/GaN high electron mobility transistors (HEMTs). In present study, the diamond films were selectively deposited on the AlGaN/GaN circular HEMT by focused (ellispoidal cavity reactor) and linear antenna (surface wave) microwave plasma at different temperatures from 400°C to 1100°C. The preliminary results on electrical measurements on the diamond-coated c-HEMTs showed degraded electrical properties comparing to c-HEMTs before deposition process, which was attributed to degradation of the Ir gate electrodes even at temperatures as low as 400°C. On the other hand, metal oxide gate electrode layer (IrO2) can withstand diamond CVD process even at high temperatures (~900°C) which make it suitable for fabrication of all-in-diamond c-HEMT devices for high-power applications.

Corrosion behavior of plasma coatings CuAl10 and CuAl50 on magnesium alloy AZ 91
Kubatík, Tomáš František ; Stoulil, J. ; Stehlíková, K. ; Slepička, P. ; Janata, Marek
The most common magnesium alloy AZ 91 is widely used as a structural material, but its use is limited at higher temperatures and high humidity. Plasma spraying is a technology that allows to prepare protective metallic and non-metallic coatings on a wide variety of substrates including magnesium and its alloys. In this study, CuAl10 and CuAl50 were plasma sprayed on magnesium alloy AZ 91 with the aim to study corrosion resistance of the plasma sprayed coatings. The corrosion resistance of layers was evaluated by the method of electrochemical potentiodynamic measurement as well as long-term corrosion tests in a condensation chamber with 0.5 mol\nNaCl at the temperature of 35 °C for 1344 hours. Layers with 1, 2, 5 passes and passes of CuAl10 with the thickness ranging from 75 to 716 mm and CuAl50 with the thickness ranging from 64 to 566 mm were prepared. The increased corrosion velocity was observed in the case of thin layers of 2 and 5 passes due to the development of a galvanic corrosion couple. The CuAl10 layer prepared with ten passes has an outstanding corrosion resistance.

Optical low dispersion rezonator as length sensor using optical frequency comb
Pravdová, Lenka ; Hucl, Václav ; Lešundák, Adam ; Lazar, Josef ; Číp, Ondřej
Ultra-high precis measurements are domain of lasers interferometers. An optical resonator measuring method using broad spectrum of radiation of an optical frequency comb was designed and experimentally verified at our workplace. The measuring of a quantity – a distance of resonator mirrors – is provided by its conversion to the value of repetition frequency of the pulse laser with mode-locked optical frequency comb. In this paper the comparison of the absolute scale of the optical resonator with an incremental interferometer scale is introduced. The incremental interferometer is implemented for verification of the optical resonator scale. The double beam incremental interferometer is operating at the wavelength of 633 nm and the measuring mirror with piezo actuator is used as one of its reflectors. It turns out that the major error signal is the reflection of the periodic nonlinearity of the incremental resonator scale. The relative resolution of our method reaches values up to 10-9 while maintaining measuring scale.

Detection of frequency noise properties of diode laser working on 729 nm
Pham, Minh Tuan ; Čížek, Martin ; Hucl, Václav ; Lazar, Josef ; Hrabina, Jan ; Řeřucha, Šimon ; Lešundák, Adam ; Číp, Ondřej
Paper report on the frequency noise investigation of the Extended Cavity Diode Laser (ECDL), working at 729 nm. The ECDL will be used as an excitation laser for the forbidden transition in a trapped and laser cooled 40Ca+ ion. For that an Hz of sub-Hz level linewidth is required. We present the experimental design for linewidth narrowing and frequency noise analysis. The linewidth is first narrowed with a phase lock loop of the ECDL onto a selected component of an optical frequency comb where the frequency noise was suppressed with a fast electronic servo-loop controller that drives the laser injection current with a high bandwidth.\n

Radio frequency resonator for feeding ion trap
Jedlička, Petr ; Pham, Minh Tuan ; Čížek, Martin ; Pavelka, Jan ; Lešundák, Adam ; Hucl, Václav ; Hrabina, Jan ; Řeřucha, Šimon ; Lazar, Josef ; Číp, Ondřej
Two versions of resonators were designed and manufactured - asymmetric and symmetric.\nThe resonator consists of a coil and capacity of ion trap which makes parallel resonant circuit.\nEnergy is supplied to the resonator through the coupling inductance. Resonator assembly was equipped with outputs for monitoring high-frequency voltage. Both versions have been tuned and tested.\n\n

Optical frequency references
Hrabina, Jan
Optical frequency references based on absorption cells represent a traditional and essential tool for frequency locking of precise laser standards. One of the most often used absorption media is a molecular iodine 127I2, which offers a rich atlas of strong and narrow absorption lines across mostly whole visible part of optical spectrum. The main disadvatage of this media can be seen in its high corrosivity and sensitivity to presence of foreign substances. This contribution is oriented to comparison of possible measurement methods for bulk- and also optical fiber- based iodine absorption cells quality and chemical purity testing.\n\n