Construction and Application of Tubular Detector and Porous Flow-through Detector/Reactor of Silver Solid Amalgam for Electrochemical Measurements in Flow Systems
Josypčuk, Oksana ; Barek, J. ; Josypčuk, Bohdan
This paper presents the preparation and application of two new arrangements of silver solid amalgam (AgSA) electrodes for measurements in flow systems  tubular detector based on compact AgSA, and flow-through detector (or reactor) prepared from porous AgSA. Both electrodes were tested for electrochemical determinations of reducible inorganic (Cd2+, Zn2+) and organic (4-nitrophenol, lomustine) compounds under FIA with amperometric detection (Cd2+, Zn2+, 4-nitrophenol) and flow-DPV (lomustine). Furthermore, by combination of the porous reactor with immobilized enzyme and tubular detector the flow amperometric enzymatic biosensor was constructed for determination of glucose in a sample of honey and cholesterol and sarcosine in model samples.
Voltammetric Determination of Herbicide Triasulfuron using Mercury Meniscus Modified Silver Solid Amalgam Electrode
Bandžuchová, L. ; Šelešovská, R. ; Chýlková, J. ; Navrátil, Tomáš
Voltammetric behavior of triasulfuron (TS), which belongs to sulfonylurea herbicide family, was studied using two working electrodes: mercury meniscus modified silver solid amalgam electrode (m-AgSAE) and hanging mercury drop electrode (HMDE) for comparison. It was found that TS provided one reduction peak on both used working electrodes. The highest response was observed in the environment of Britton-Robinson buffer (BR) of pH 3 (m-AgSAE) and 2.5 (HMDE), respectively. Working parameters of differential-pulse voltammetry (DPV) were optimized and this method was applied in analysis of agricultural formula and river water.
Continuous Glucose Monitoring by Real Time Sensor in Interstitial Fluid
Honsová, Š. ; Navrátil, Tomáš
The aim of this contribution is to compare the differences between accuracy claimed by the manufacturer in continuous glucose monitoring using the MiniMed Paradigm REAL-Time system with the results obtained in a patient during physical activity. Electrochemical glucose sensor measures the glucose oxidase reaction products. Measurement accuracy was determined using Clarke Error Grid analysis. It can be concluded that in the normal glucose range (4.4 to 10.0 mmol/ l) was more accurate than the measurements given by the manufacturer, in the opposite case; hyperglycemia is less precise than declared.
Optimization of a Flow Rate for a Hyphenation of Voltammetry with Electrospray Ionization Mass Spectrometry
Jaklová Dytrtová, Jana ; Jakl, M. ; Norková, Renáta ; Navrátil, Tomáš
The hyphenation of an electrochemical cell prior to mass spectrometer with electrospray ionization allows studying of products and/or of intermediates of electrode reactions. The measurement is realized in a flowing system. The flow rate of the sample markedly influences the MS signal intensity of the product. The calculated optimum value for the electrochemical cell with the sweep volume 0.72 μL is in the range from 0.4 to 0.5 mL h -1 . The experimental optimal value is 0.45 mL h -1 . The optimization of the flow rate has to be provided individually for each product, because the intensity also depends on the rate of the electrode reaction and product stability.
(Strept)avidin-biotin interactions at amalgam electrodes covered by thiol monolayer
Josypčuk, Bohdan ; Mareček, Vladimír ; Yosypchuk, O.
Carboxylic group of 11-mercaptoundecanoic acid (MUA) can be used to creat a peptide bond with species containing amino group, e.g., peptides, and proteins. By the help of EDC-NHS technology, streptavidin or avidin was covalently bonded with MUA-monolayer at a silver solid amalgam electrode. Such prepared electrode was used for detecting biotin and biotinylated albumin in the supporting electrolyte (0.15 M NaCl, 0.05 M TRIS, pH 7.0). Electrochemical impendance spectroscopy was performed for the biosensor response monitored by impedance spectroscopy. Binding of biotin or biotinylated albumin with (strept)avidin a change in the resistance of the sensor in the concentration range of 0.5-20 μg mL-1. Electrochemical regeneration of the amalgam electrode permits simply to renew its surface and to create the new biosensor.
Influence of LMWOAs Transport of Cadmium and Copper Ions Across Phospholipid Bilayer Using Calcium Ionophore A23187
Šestáková, Ivana ; Parisová, Martina ; Navrátil, Tomáš ; Jaklová Dytrtová, Jana
The influence of oxalic, citric or malic acid on transport of cadmium and copper ions in dependence on pH has been studied. Artificial phospholipid bilayer containing wide-spectrum ionophore was prepared on polycarbonate support and its formation and stability was followed with electrochemical impedance spectroscopy. The species, transported across phospholipid bilayer were determined with voltammetry. The substantial influence of complexes formed with metal ions and LMWOAs on their transport has been confirmed.
Assessment of Potential Risk Connected with the Use of Mercury and Mercury Electrodes
Navrátil, Tomáš ; Švancara, I. ; Mrázová, K. ; Nováková, Kateřina ; Chýlková, J. ; Pelclová, D.
This contribution tries to asses critically the danger connected with utilization of mercury in different branches of human activites. The main attention was devoted to electrochemistry, mainly to voltammetry and polarography. However, to other branches were characterized as well: dentistry, in battery production, mining industry, and a few others. The most toxic and contarily almost nontoxic forms of mercury and of its compounds were characterized. Some interesting cases of exposure to mercury, according to the database of the Czech Toxicological Information Centre (TIC) (from years 1995-2011), have been reported,
Use of Copper Solid Amalgam Electrode for Determination of Triazolic Fungicide Tebuvonazole
Nováková, Kateřina ; Navrátil, Tomáš ; Jaklová Dytrtová, Jana ; Chýlková, J.
With the use newly developed mercury meniscus-modified copper solid amalgam electrode (inner diamter 1.5 mm), the voltammetric behavior of fungicide tebuconazole was researched by differential pulse voltammetry (DPV) and cyclic voltammetry (CV). Applying CV and elimination voltammetry with linear scan (EVLS), the reaction mechanism was investigated. The optimum conditions for DPV determination of this triazolic fungucude were identified in Britton-Robinson buffer/methanol (1:1, v/v) of pH 6.3 DPV with optimized parameters (Ein = +400 mV vs. Ag/AgCl/3M KCl, scan rate 20 mV s-1) was used for determination of determination of tebuconazole in analyzed solutions. Application the prolonged time (60 s), the limit of detection 2.10-7 molL-1. The applicability of the developed method was verified on the analysis of the real soil solution sample.
Investigation of Complexes of Tebuconazole with Zinc
Jakl, M. ; Norková, Renáta ; Navrátil, Tomáš ; Jaklová Dytrtová, Jana ; Balík, J.
Tebuconazole is one of the most utilized triazole pesticides in agriculture. Its stability is highly affected by complexation with metals. Moreover, it creates more or less stable complexes with essential elements that become unavailable to plants. In the system with overbundant tebuconazole, an inert (very stable) complex with Zn was found. Elimination voltammetry wit linear scan was used for revealing of the electrode processes on the mercury surface. The relatively slow kinetically controlled step in tebuconazole/Zn complex formation indication indicates the great ability of Zn-tebuconazole system to react with more ligans. Therefore, multiligand Zn-tebuconazole complexes with other ligands are expected in the nature.
Transport of Copper Ions in the Presence and Absence of Ionosphere Calcimycin and the Influence of LMWOAs on this Transport
Parisová, Martina ; Navrátil, Tomáš ; Šestáková, Ivana ; Mareček, Vladimír
This work was focussed on preparation of model membranes formed on porous polycarbonate substrate. 1,2-dipalmytoil-sn-glycero-3-phosphocholine was used to form stable lipid bilayers in hydrophilic pores of polycarbonate membrane. For their characterization, electrochemical impendance spectroscopy (EIS) and voltammetry were applied. The transport of copper ions across these membranes in presence and absence of ionophore calcimysin has been studied. The effect of LMWOAs on transporting processes was investigated too.