Original title:
Rodinný dům
Translated title:
Family house
Authors:
Smolicová, Miriam ; Smolková Mizerová, Lenka (referee) ; Smolka, Radim (advisor) Document type: Bachelor's theses
Year:
2024
Language:
cze Publisher:
Vysoké učení technické v Brně. Fakulta stavební Abstract:
[cze][eng]
Cieľom tejto bakalárskej práce je naprojektovať moderný pasívny rodinný dom. Motiváciou tejto práce je dokázať, že aj luxusné vily môžu spĺňať pasívny štandard. Je to dvojposchodový rodinný dom s jedným podzemným podlažím s plochou zelenou strechou z časti pochôdznou. V suteréne sa nachádza herňa s technickou miestnosťou. Prvé nadzemné podlažie sa skladá zo zádveria, WC, obývacej miestnosti s jedálňou, kuchyne, skriňou s potravinami, chodby, práčovne, dvoch kúpeľní, dvoch detských izieb, spálne a šatníka. Na druhom nadzemnom podlaží sa nachádza ateliér a WC. Nosné prvky, steny, sú navrhnuté z vápenno-pieskových tvaroviek. Stropná nosná konštrukcia je navrhnutá z predpätých stropných panelov. Budova je zakladaná na základových pásov z betónových tvaroviek a monolitického betónu. Predbežný návrh TZB zahŕňa návrh vzduchotechniky, zameraný na množstvo vzduchu s predbežnými trasami potrubia, návrh ZTI zameraný na umiestenie stúpajúceho potrubia a hospodárenie s dažďovou vodou, návrh elektroinštalácií, zameraný na hlavný istič, domový rozvádzač a návrh fotovoltaickej elektrárne. Podrobnejší návrh TZB zahŕňa vykurovanie. Návrh pozostáva z podlahového vykurovania a radiátorov, ktoré budú napojené na tepelné čerpadlo vzduch-voda. TUV je ohrievaná tepelným čerpadlom s pomocným zdrojom s elektrickou špirálou. Všetky komponenty, ako zásobník teplej vody a expanzná nádrž, sú umiestené v technickej miestnosti v suteréne. Tento dizajn spĺňa požiadavky na triedu A v energetickom certifikáte. Ďalšou súčasťou práce je posudok požiarneho bezpečnostného riešenia, akustický posudok a posudok z hľadiska tepelnej techniky.
The aim for this bachelor work is design of modern passive detached house. Vision for this design is proving that even luxury villas can be in passive standard. It is three storey house with flat roof part of which it’s walkable and part green roof. The basement includes game room and utility room. In first floor we have main lobby, lavatory, living room with dining room, kitchen, pantry, hall, laundry room, bathroom, two kid’s rooms, main bedroom, walk-in closet and en-suite bathroom. On second floor there’s only studio and lavatory. Load bearing elements are walls from sand-lime bricks, floor and roof slabs from prestressed concrete panels. This building is based on foundation strips from reinforced concrete. eliminary designs of building services are mechanical ventilation with heat recovery, in which design is focused on amount of circulated air with added scheme of pipe installations, sanitary installations, which consist of scheme of plumbing and sanitary sewer pipes. Design of building services also consisted of simple design of main circuit break and photovoltaic panels. In more detailed design is design of rain water reuse with rain water tanks for accumulation and infiltration. Main design of building services is heating. It’s designed underfloor heating and radiators which will be powered by heat pump air-water. Domestic hot water is heated with heat pump and electric immersion heater as auxiliary source. All components such as hot water cylinder and expansion tank are placed in utility room in basement. This design meets criteria for grade A in energy performance certificate.
Keywords:
air-water heat pump; building with nearly zero energy consumption; lime-sand blocks; prestressed roof slabs; underfloor heating; walkable green flat roof; budova s takmer nulovou spotrebou energie; energetický certifikát trieda A; pochôdzna zelená plochá strecha; podlahové vykurovanie; predpäté stropné panely; tepelné čerpadlo vzduch-voda; vápenno-pieskové tvarovky
Institution: Brno University of Technology
(web)
Document availability information: Fulltext is available in the Brno University of Technology Digital Library. Original record: https://hdl.handle.net/11012/247003