Original title: Removal of PFASs from sewage sludge by pyrolysis
Authors: Hušek, Matěj
Document type: Papers
Conference/Event: Bažant Postgraduate Conference 2022, Prague (CZ), 20220613
Year: 2022
Language: eng
Abstract: Our work aimed to describe PFASs behaviour at different pyrolysis temperatures (200 to 700 °C). We analysed 37 PFAS in sewage sludge samples and pyrolysis products. The temperature at which PFASs were removed from the sewage sludge at more than 99.0% was 400 °C, and at 600 °C, removal was more than 99.9%. As a result, it is recommended for commercial sludge pyrolysis units (larger volume, lower material homogeneity) that the process temperature be not lower than 600 °C. This recommendation is supported and demonstrated by the analyses of samples from the Bohuslavice Trutnov WWTP (CZE), where the sludge pyrolysis unit is in operation.\n
Keywords: pyrolysis; sewage sludge samples; temperature
Project no.: QK21020022, StrategieAV21/3
Funding provider: GA MZe, AV ČR
Host item entry: Proceedings of Abstracts, ISBN 978-80-86186-24-5
Rights: This work is protected under the Copyright Act No. 121/2000 Coll.

Institution: Institute of Chemical Process Fundamentals AS ČR (web)
Original record: http://hdl.handle.net/11104/0332138

Permalink: http://www.nusl.cz/ntk/nusl-508640


The record appears in these collections:
Research > Institutes ASCR > Institute of Chemical Process Fundamentals
Conference materials > Papers
 Record created 2022-09-28, last modified 2023-12-11