Název: Spectral Computed Tomagraphy: Comparison Of Real And Virtual Native Images
Autoři: Širůčková, Kateřina
Typ dokumentu: Příspěvky z konference
Jazyk: eng
Nakladatel: Vysoké učení technické v Brně, Fakulta elektrotechniky a komunikačních technologií
Abstrakt: This paper is based on the comparison of real and virtual native images obtained from spectral computed tomography (CT). Both types of images are compared by the signal-to-noise ratio (SNR), HU/HU* ratio and in the relation of used contrast medium. Parametric and non-parametric tests were used for statistical analysis of the measurements. The main purpose of this study is to contribute on the wider issue which is radiation dose reduction on the patient. This problem has not been fully researched yet but it has been proposed that the virtual images could be computed mathematically from the images acquired by the conventional scanning protocol for spectral CT and used instead of the real images.
Klíčová slova: dual energy; Spectral CT; true non-contrast imaging; virtual non-contrast imaging
Zdrojový dokument: Proceedings II of the 26st Conference STUDENT EEICT 2020: Selected papers, ISBN 978-80-214-5868-0

Instituce: Vysoké učení technické v Brně (web)
Informace o dostupnosti dokumentu: Plný text je dostupný v Digitální knihovně VUT.
Původní záznam: http://hdl.handle.net/11012/200614

Trvalý odkaz NUŠL: http://www.nusl.cz/ntk/nusl-447666


Záznam je zařazen do těchto sbírek:
Školství > Veřejné vysoké školy > Vysoké učení technické v Brně
Konferenční materiály > Příspěvky z konference
 Záznam vytvořen dne 2021-07-25, naposledy upraven 2021-08-22.


Není přiložen dokument
  • Exportovat ve formátu DC, NUŠL, RIS
  • Sdílet