Original title: Microstructural models of trabecular bone - comparison of CT-based FE models
Authors: Jiroušek, Ondřej ; Zlámal, Petr
Document type: Papers
Conference/Event: Engineering Mechanics 2011 /17./, Svratka (CZ), 2011-05-09 / 2011-05-12
Year: 2011
Language: eng
Abstract: In the article a detailed comparison of techniques used to developed detailed FE models of trabeculra bone microstructure is presented. The FE models are built using a stack of microtomographic images of trabecular bone. Compression test of a cylindrical sample taken from human proximal femur is virtually performed using FE models developed using different procedures. Effect of improper segmentation, mesh smoothing, mesh density, use of hexahedral/ tetrahedral elements, linear/ quadratic shape function is evaluated in parametric study. Material model is based on nanoindentation and numerical elastic properties of sample are compared to experimental results.
Keywords: mesh quality; microstructural FE model; trabecular bone
Project no.: CEZ:AV0Z20710524 (CEP), GAP105/10/2305 (CEP)
Funding provider: GA ČR
Host item entry: Engineering Mechanics 2011, ISBN 978-80-87012-33-8

Institution: Institute of Theoretical and Applied Mechanics AS ČR (web)
Document availability information: Fulltext is available at the institute of the Academy of Sciences.
Original record: http://hdl.handle.net/11104/0197495

Permalink: http://www.nusl.cz/ntk/nusl-42828


The record appears in these collections:
Research > Institutes ASCR > Institute of Theoretical and Applied Mechanics
Conference materials > Papers
 Record created 2011-07-04, last modified 2024-01-26