Original title:
Měření obrobků na obráběcích strojích pomocí obrobkové sondy
Translated title:
Measurement of workpieces on machine tools using a touch probe
Authors:
Velič, Samuel ; Marek, Tomáš (referee) ; Holub, Michal (advisor) Document type: Master’s theses
Year:
2020
Language:
cze Publisher:
Vysoké učení technické v Brně. Fakulta strojního inženýrství Abstract:
[cze][eng]
Táto diplomová práca sa zaoberá vplyvom elektronickej kompenzácie na presnosť merania pri použití obrobkovej sondy. Teoretická časť sa zaoberá obrobkovími sondami, konkrétne ich členením, princípmi fungovania a aplikáciami. Sú v nej taktiež rozobrané prístroje použité v pokuse. Sú nimi double ballbar, laser interferometer a LaserTRACER. V praktickej časti je popísaný pokus demonštrujúci závislosť spresnenia sondy na stupni elektronickej kompenzácie. Všetky merania v pokuse prebiehali v súlade s normou VDA 5 a boli vyhodnotené prostredníctvom programu Matlab. Výstupom skriptu v Matlabe sú grafy závislosti tolerancie spôsobilosti merania na dĺžke etalónu. Na konci tejto práce sú na základe vygenerovaných grafov vyvodené čiastkové závery, ktoré prehľadne porovnávajú vplyv jednotlivých konfigurácií stroja na presnosť sondy.
This diploma thesis deals with the influence of electronic compensation on accuracy of the measurement using the touch probe. The theoretical part concerns touch probes, specifically their classification, principles of working and applications. This part also includes devices used later in the experiment, particularly double ballbar, laser interferometer and LaserTRACER. The Practical part describes an experiment, demonstrating the correlation between the accuracy improvement of the touch probe and the electronic compensation’s level. All measurements were executed in accordance with the norm VDA 5 and were evaluated by the Matlab software. The graphs of reliance tolerance of capability of measurement on the length of the benchmark. At the end of this diploma thesis there are partial conclusions deduced. The deduction is based on generated graphs. The partial conclusions synoptically compare the influence of individual machine´s configurations on the accuracy of the touch probe.
Keywords:
double ballbar; electronic compensation; geometric accuracy of machine; laser interferometer; LaserTRACER; touch probe; volumetric accuracy of machine; double ballbar; elektronická kompenzácia; geometrická presnosť stroja; laser interferometer; LaserTRACER; obrobková sonda; volumetrická presnosť stroja