Home > Conference materials > Papers > Comparison of Microwave and Direct Burner Heating During In-Situ Pilot Scale Remediation on the Area of Machinery Company.
Original title:
Comparison of Microwave and Direct Burner Heating During In-Situ Pilot Scale Remediation on the Area of Machinery Company.
Authors:
Mašín, P. ; Maštalka, J. ; Sobek, Jiří ; Hájek, Milan Document type: Papers Conference/Event: International Conference on Chemical Technology /5./, Mikulov (CZ), 20170410
Year:
2017
Language:
eng Abstract:
On the area of machinery company was performed the pilot scale testing of microwave and classical heating unsaturated zone of soil heavily contaminated with nonpolar hydrocarbons, especially cutting oils. Heating was conducted to a depth of 2.5 m due to the high groundwater table depth -2,8 m. Conventional heating was represented by a direct flame burner placed on the top of application borehole. Hot exhaust gas was introduced into another borehole, where was utilized remainder of energy. There was used diesel burner with an power 16 kW.
Keywords:
innovative technology; machinery company; microwave and direct burner heating Host item entry: Book of Abstracts, ISBN 978-80-86238-62-3
Rights: This work is protected under the Copyright Act No. 121/2000 Coll.