Original title: Fundamental aspects of acetabular cups of THR
Authors: Jírová, Jitka ; Micka, Michal ; Jíra, Josef ; Sosna, A. ; Pokorný, D.
Document type: Papers
Conference/Event: Konference k 10. výročí založení fakulty., Praha (CZ), 2003-05-26 / 2003-05-27
Year: 2003
Language: eng
Abstract: Conical acetabular cups, which migrated across lamina in the course of years, were retreived and evaluated. Just at the contact between bone and artificial material of the implant overloading or on the contrary insufficient loading of the trabecular bone tissue and undesirable micromotion of the acetabular implant were observed.
Keywords: FEM; finite elements method; orthopaedics; Orthopaedics; pelvis; metoda konečných prvků; ortopedie; pánev
Project no.: CEZ:AV0Z2071913 (CEP), CEZ:MSM 21200025
Host item entry: Doprava a telekomunikace pro 3.tisíciletí, ISBN 80-01-02741-4

Institution: Institute of Theoretical and Applied Mechanics AS ČR (web)
Document availability information: Fulltext is available at the institute of the Academy of Sciences.
Original record: http://hdl.handle.net/11104/0106078

Permalink: http://www.nusl.cz/ntk/nusl-30507


The record appears in these collections:
Research > Institutes ASCR > Institute of Theoretical and Applied Mechanics
Conference materials > Papers
 Record created 2011-07-01, last modified 2021-11-24


No fulltext
  • Export as DC, NUŠL, RIS
  • Share