Original title:
Digital Controlled Electronics for Three-dimension Hydrophone Position System
Authors:
Václavík, V. ; Rozman, J. ; Číp, Ondřej ; Mikel, Břetislav Document type: Papers Conference/Event: Radioelektronika 2001 /11./, Brno (CZ), 2001-05-10 / 2001-05-11
Year:
2001
Language:
eng Abstract:
Set of geared DC motors is employed as mechanical actuator for three-dimensional positioning of the needle hydrophone probe in the ultrasound scannig tank. High-resolution position sensors inside DC motors and a digital signal processing used for digital PID servo-loop improves dynamic range and precision of the sensor position set up.
Keywords:
DC motors; needle hydrophone probe Project no.: CEZ:AV0Z2065902 (CEP), GA102/00/0936 (CEP), GA202/99/0959 (CEP), GA101/00/0974 (CEP), IAA2065803 (CEP), IAB2065001 (CEP) Funding provider: GA ČR, GA ČR, GA ČR, GA AV ČR, GA AV ČR Host item entry: 11th International Czech - Slovak Scientific Conference Radioelektronika 2001 Conference Proceedings, ISBN 80-214-1861-3 Note: Související webová stránka: mailto:ocip@isibrno.cz
Institution: Institute of Scientific Instruments AS ČR
(web)