Název:
Determination of Accidental Doses by Means of Individual Dosimeters of CSOD and other Detectors
Autoři:
Trousil, J. ; Spurný, František Typ dokumentu: Příspěvky z konference Konference/Akce: Days of Radiation protection /XXV./, Jáchymov (CZ), 2002-11-27 / 2002-11-29
Rok:
2002
Jazyk:
eng
Abstrakt: OECD organized at June 2002 an intercomparison of accidental dosimetry systems. It was realised at the reactor SILENE, Valduc, France. Czech Republic participated in the intercomparison with system based on Si-diodes and thermoluminescent detectors (TLD), and with routine individual CSOD dosimeters. The result obtained are discussed and analysed. Recommandations how to assure accidental dosimetry in the Czech Republic are formulated.
Klíčová slova:
albedo dosimeter; detectors; Si-diodes Číslo projektu: CEZ:AV0Z1048901 (CEP) Zdrojový dokument: Conference Abstracts XXV. Days of radiation protection, ISBN 80-01-02651-5
Instituce: Ústav jaderné fyziky AV ČR
(web)
Informace o dostupnosti dokumentu:
Dokument je dostupný v příslušném ústavu Akademie věd ČR. Původní záznam: http://hdl.handle.net/11104/0082045