Original title:
Penetration Through CE-Marked Respirators - Cut-Based Versus Manikun-Based Method
Authors:
Ondráček, Jakub ; Serfozo, N. ; Zíková, Naděžda Document type: Papers Conference/Event: Výroční konference České aerosolové společnosti /16./, Želiv (CZ), 2015-10-22 / 2015-10-23
Year:
2015
Language:
eng Abstract:
This work presents size-resolved penetration testing of 13 commercially available filtering facepieces (FFP1, FFP2 and FFP3 filtering classes) on pieces of filtration material (47 mm in diameter) cut from various FFRs (referred as cut-based). Second objective of this work was to measure the size-resolved penetration of 9 complete FFRs (selected from identical filtering facepieces as in the first case) placed on the manikin (refered as manikin-based). The results obtained by these two methods were compared and the real MPPS of all FFRs obtained by both methods were estimated.
Keywords:
cut-based; respirators; size resolved penetration Project no.: 315760 Host item entry: Proceedings of 16th Annual Conference of the Czech Aerosol Society, ISBN 978-80-86186-73-3 Note: Související webová stránka: http://hdl.handle.net/11104/0251519
Rights: This work is protected under the Copyright Act No. 121/2000 Coll.