National Repository of Grey Literature 51 records found  1 - 10nextend  jump to record: Search took 0.01 seconds. 
SMV-2023-59: Programmable acquisition system AQS-PG V2.0
Vondra, Vlastimil
Assessment of the equipment specification in terms of the equipment implementation possibilities using the contractor's instrumentation. Analysis of the requirements of the assignment and development of the generator solution methodology. Preparation of a proposal for implementation according to the desired characteristics. Manufacturing mechanical and electrical parts and purchasing the necessary components. Verification of theoretical initial requirements by practical measurements at a designated location. Assembling 1 piece of experimental equipment. Installation, calibration of equipment at the filling site. Operator training at the client's.
Frequency synthesizer for microwave communication systems
Klapil, Filip ; Vondra, Vlastimil (referee) ; Kasal, Miroslav (advisor)
The main aim of the thesis is to develop a solution of a frequency synthesizer for a microwave communication systems. Specifically, it suggests a design for frequency synthesizer with phase-locked loop. At beginning of the thesis the principle and basic properties of this method of signal generation are explained. Then it is followed by a brief discussion of the parameters of synthesizers and their influence on design. Another part of the work is the analysis of circuit the frequency synthesizer with the phase-locked loop MAX2871, which is followed by a proposal for the design of the frequency synthesizer module hardware. The last part of the work deals with practical implementation, verification of function and measurement of achieved parameters and their evaluation.
Evaluation of pulse Wave Velocity Based on Whole-Body Bioimpedance
Soukup, Ladislav ; Tyšler, Milan (referee) ; Vrba, Jan (referee) ; Vondra, Vlastimil (advisor)
This thesis deals with the methodology of use of whole-body impedance cardiography for evaluation of pulse wave velocity. The first three chapters explain selected hemodynamic properties of the arterial system related to the issue of pulse wave propagation. At the same time the ordinary methods for estimation, its disadvantages and merits has been summarized. Points at issue of whole-body impedance evaluation methodology for pulse wave velocity are researched in second part of this thesis. In order that analysis the procedure for correct methodology has been determined. Particularly determination of reference proximal point for calculation of transit time towards aortic valve, and design and accuracy of transit distance measurement were discussed. Based on the obtained data, a calculation of representative pulse wave velocity to eight limb locations was performed.
Processing of heart sounds signals
Němcová, Simona ; Matějková, Magdaléna (referee) ; Vondra, Vlastimil (advisor)
This bachelor thesis is focused on the heart sound signal. It describes the principles of hear sound formation, measurement methods and especially the analysis of the measured phonocardiography signal. In the practical part of this thesis, the algorithm for detecting the first and the second heart sounds is designed by using MATLAB software. Its principle is realized in finding maximum or center of gravity in the filtered phonocardiography signal.
Processing of a continual blood pressure signal
Svobodová, Ivana ; Soukup, Ladislav (referee) ; Vondra, Vlastimil (advisor)
Bachelor thesis contains a general description of the blood pressure phenomenon and its importance and also deals with diseases, such as hypotension and hypertension. The work also includes a literature review of blood pressure measuring methods. Closely are discussed the non-invasive methods. The result of the work is also a unique program designed in Matlab, which is developed for signal processing of continuous blood pressure measurement for detection of SBP and DBP and MAP, pulse after pulse. To verify the functionality of the program, the further implementation was carried out in GUI. In conclusion, the obtained data are beeing analyzed statistically.
Modulation signal source for microwave beacon
Belloň, Michal ; Vondra, Vlastimil (referee) ; Kasal, Miroslav (advisor)
This project is focused on construction of source of modulation signal for microwave beacon. The output signal is the same as signal, which is generated by PC software WSJT (Weak Signal by Joe Taylor) on PC sound card output. Signal on device output is modulated using by WSJT modulation and its specific JT4 mode. The device output has I and Q components of signal.
Direct digital synthesizerfor microwave application
Dluhý, Vojtěch ; Vondra, Vlastimil (referee) ; Kasal, Miroslav (advisor)
The aim of this thesis is introduce readers to the basics of digital frequency synthesis and design of direct digital synthesizer with circuit AD9951 by Analog Devices. The device will be controlled from a PC via RS232. The device will work with internal oscillator, with the ability to connect an external frequency standard.
Evaluation of cardiac output by bioimpedance method with patients with pacemaker
Soukup, Ladislav ; Cimbálník, Jan (referee) ; Vondra, Vlastimil (advisor)
This thesis deals with the possibility of using impedance cardiography for calculating cardiac output. Kubicek’s, Sramek‘s and Sramek-Bernstein‘s methods are discussed here. These methods were applied to a data set, obtained by measuring on subjects with implanted cardiostimulators. The subjects’ heart rate was being changed by the programing of cardiostimulators. Thanks to this procedure the measured data were not affected by artifacts, connected with the heart rate change caused by a body stress, or other influences. An influence of heart rate on a cardiac output value based on the statistical processing of the data set was studied.
Direct digital synthesizerfor microwave application
Dluhý, Vojtěch ; Vondra, Vlastimil (referee) ; Kasal, Miroslav (advisor)
The aim of this thesis is introduce readers to the basics of digital frequency synthesis and design of direct digital synthesizer with circuit AD9951 by Analog Devices. The device will be controlled from a PC via USB. The device works with internal oscillator, with the ability to connect an external frequency standard of 10 MHz. On input is frequency doubler with transistor. Outpu signal is filtered by low-pass filter and amplified by monolitic amplifier ERA-3+.
Thermal comfort and its estimation
Žáková, Monika ; Vondra, Vlastimil (referee) ; Nováková, Zuzana (advisor)
This paper summarizes the problems of human thermoregulation and its measurement, with a focus on the method of indirect calorimetry in resting conditions at different ambient temperatures and during physical activity. It also introduces the issue of human thermal comfort and the methodology of its monitoring using thermal manikin. It describes PowerCube Ergo (Ganshorn, Germany) and Cardiovit AT-104 (Schiller, Switzerland), the diagnostic devices used to spiro-ergometry measurements. It introduces the options to export data. The work proposes the protocol for measuring the thermoregulation of the small group of volunteers, which is realized by the practical part. According to the same protocol is monitored thermal comfort of the thermal manikin. In MATLAB is created the application, allowing clear analysis of measurement records. The data are evaluated and discussed.

National Repository of Grey Literature : 51 records found   1 - 10nextend  jump to record:
Interested in being notified about new results for this query?
Subscribe to the RSS feed.