Home > Reports > Research reports > Theory of Electrodiffusion Friction Probes in Microdisperse Liquids 6. Effect of Insulating Gaps in DL Approximation
Original title:
Theory of Electrodiffusion Friction Probes in Microdisperse Liquids 6. Effect of Insulating Gaps in DL Approximation
Translated title:
Teorie elektrodifuzních čidel tření v mikrodisperzních kapalinách 6. Vliv isolačních mezer v aproximaci difuzní vrstvy
Authors:
Wein, Ondřej Document type: Research reports
Year:
2007
Language:
eng Abstract:
[eng][cze] Insulated insertions between individual segments of direction-sensitive electrodiffusion friction probes attenuate the direction sensitivity. Quantitative study of this effect by Wein and Wichterle (1989) for Newtonian liquids is expanded on the microdisperse liquids, displaying the Apparent Wall Slip, i.e. a non-linear velocity profile close to solid surfaces.Isolační vložky mezi jednotlivými segmenty směrově citlivých elektrodifuzních čidel zeslabují jejich směrovou citlivost. Kvantitativní studie tohoto efektu od Weina a Wichterleho (1989) pro Newtonské kapaliny je rozšířena na mikrodisperzní kapaliny, vykazující zdánlivý skluz při stěně, tj. nelinární rychlostní profil v blízkosti pevných povrchů.
Keywords:
apparent slip at wall; direction-sensitive friction Ppobes; electrodiffusion diagnostics of flow Project no.: CEZ:AV0Z40720504 (CEP)
Institution: Institute of Chemical Process Fundamentals AS ČR
(web)
Document availability information: Fulltext is available at the institute of the Academy of Sciences. Original record: http://hdl.handle.net/11104/0158043