National Repository of Grey Literature 16 records found  1 - 10next  jump to record: Search took 0.00 seconds. 
Design apparatus for measuring geometric accuracy of machine tools
Holcman, David ; Marek, Tomáš (referee) ; Holub, Michal (advisor)
This bachelor’s work deals with modern methods of geometric accuracy measurement of machine tools, modal analysis and definition of demands on used agents during the measurement process. A part of this work is dedicated to description of numerical finite element method, which is the cornerstone of ascertaining the natural frequencies by a software program. In the closing part the appropriate adjustments of minimisation of influence on measurement are suggested.
Building and control of 5-axis milling machines
Anderle, Milan ; Knobloch, Josef (referee) ; Holub, Michal (advisor)
This bachelor’s thesis studies the building and control of the five-axis CNC machining centres. Modern methods of geometric accuracy measurements are described with possibilites of compensating for geomeric and volumetric errors. Measuring devices described in this thesis are laser interferometer XL-80 and ballbar QC20-W for measuring geometric accuracy of MCV 754 Quick machine. The aim of the thesis is to describe current trends in construction, design and controlling of five-axis milling machines.
Data processing from measuring machine tools
Jelínek, Adam ; Marek, Tomáš (referee) ; Holub, Michal (advisor)
The aim of this bachelor thesis is to propose a procedure of an implementation of periodic control of geometric accuracy of machine tools into the maintenance process in Walter s.r.o. company. To carry out an initial series of measurements, evaluate collected data and to advice further actions based on the evaluation. Presented thesis also introduces some quality management tools, which may be used for the implementation of the process.
Impact of conventional compensation to the volumetric accuracy of the machine tool
Žák, Zdeněk ; Vetiška, Jan (referee) ; Holub, Michal (advisor)
This thesis solves the impact of conventional compensation to the volumetric accuracy of the CNC machine. It is therefore a practical research work, where are in the theoretical introduction mentioned requirements for machine tools, the types of errors that can occur on three-axis kinematics, compensation for the control system Siemens Sinumerik 840D sl and devices by means of which are these compensation under the work formed and subsequently verified. In this work can be seen the measured values and graphs from each measurements, a detailed analysis of the results and drawing conclusions from these results.
Assessment of geometric accuracy of machining center using digital inclinometers
Únar, Jan ; Marek, Tomáš (referee) ; Holub, Michal (advisor)
This diploma thesis deals with assessment of geometric accuracy of machining center MCV 754 QUICK. BlueSYSTEM digital inclinometers from WYLER AG, XL-80 laser interferometer from RENISHAW, Ballbar QC20-W from RENISHAW and LaserTRACER self-guiding laser interferometer from ETALON AG were used to measure accuracy. Error of the X straightness in the direction of the Z axis was assessed. The first part of the paper describes the geometric accuracy of the machine, currently available instruments for measuring geometric accuracy and an explanation of straightness. The second part consists of the design of measurements, experiment, evaluation and comparison of results and recommendations for teaching.
Volumetric accuracy of machine tools
Máčala, Daniel ; Marek, Tomáš (referee) ; Holub, Michal (advisor)
The diploma thesis deals with the influence of the volumetric accuracy of the machine tool on the size of the assessed work space. The impact assessment was carried out on the basis of tests of a three-axis vertical CNC machining center. The thesis is divided into two parts, theoretical and practical. The theoretical part is focused on geometric / volumetric accuracy of machine tools, measuring technique for measuring geometric errors and Design of Experiment. In the practical part, there is an analysis of the Design of Experiment according to Shainin, description of the work with the measuring instruments and the measurement of the geometric / volumetric accuracy of the machine including statistical evaluation. The output of the thesis is the description of the influence of volumetric deviation on the size of the measured work space by means of statistical methods.
Current trends and measuring principles of machine tools and their parts
Nedbal, David ; Knobloch, Josef (referee) ; Merenus, Ondřej (advisor)
This bachelor’s thesis studies the measuring of machining centers. Studying issues in measuring of that centers, geometric tolerations and also description of modern and nowadays techonolgies including interferometer and systems like laser tracker, laser tracer or ballbar. This thesis studies also masuring of five-axis machining centers and issues in this measuring.
Assessing the influence of operating conditions on the resulting circularity and positioning accuracy
Sarvaš, Matej ; Marek, Tomáš (referee) ; Holub, Michal (advisor)
This thesis assesses the influence of operating conditions such as feed rate, position on the machine and temperature of individual machine components on the resulting positioning accuracy and circularity of a CNC machine. At the beginning, the current state of the art of the problem is described, such as types of machine accuracy, machine tool errors and their measurement. Subsequently, a system analysis of the problem is developed, where all the factors affecting the machine are described and a method for testing the machine is proposed. In the penultimate chapter, the proposed measurements are processed and in the last chapter they are evaluated.
Assessment of geometric accuracy of machining center using digital inclinometers
Únar, Jan ; Marek, Tomáš (referee) ; Holub, Michal (advisor)
This diploma thesis deals with assessment of geometric accuracy of machining center MCV 754 QUICK. BlueSYSTEM digital inclinometers from WYLER AG, XL-80 laser interferometer from RENISHAW, Ballbar QC20-W from RENISHAW and LaserTRACER self-guiding laser interferometer from ETALON AG were used to measure accuracy. Error of the X straightness in the direction of the Z axis was assessed. The first part of the paper describes the geometric accuracy of the machine, currently available instruments for measuring geometric accuracy and an explanation of straightness. The second part consists of the design of measurements, experiment, evaluation and comparison of results and recommendations for teaching.
Volumetric accuracy of machine tools
Máčala, Daniel ; Marek, Tomáš (referee) ; Holub, Michal (advisor)
The diploma thesis deals with the influence of the volumetric accuracy of the machine tool on the size of the assessed work space. The impact assessment was carried out on the basis of tests of a three-axis vertical CNC machining center. The thesis is divided into two parts, theoretical and practical. The theoretical part is focused on geometric / volumetric accuracy of machine tools, measuring technique for measuring geometric errors and Design of Experiment. In the practical part, there is an analysis of the Design of Experiment according to Shainin, description of the work with the measuring instruments and the measurement of the geometric / volumetric accuracy of the machine including statistical evaluation. The output of the thesis is the description of the influence of volumetric deviation on the size of the measured work space by means of statistical methods.

National Repository of Grey Literature : 16 records found   1 - 10next  jump to record:
Interested in being notified about new results for this query?
Subscribe to the RSS feed.