National Repository of Grey Literature 259 records found  beginprevious172 - 181nextend  jump to record: Search took 0.00 seconds. 
Transport of Copper Ions in the Presence and Absence of Ionosphere Calcimycin and the Influence of LMWOAs on this Transport
Parisová, Martina ; Navrátil, Tomáš ; Šestáková, Ivana ; Mareček, Vladimír
This work was focussed on preparation of model membranes formed on porous polycarbonate substrate. 1,2-dipalmytoil-sn-glycero-3-phosphocholine was used to form stable lipid bilayers in hydrophilic pores of polycarbonate membrane. For their characterization, electrochemical impendance spectroscopy (EIS) and voltammetry were applied. The transport of copper ions across these membranes in presence and absence of ionophore calcimysin has been studied. The effect of LMWOAs on transporting processes was investigated too.
Artificial phospholipid membranes as models of real membranes and transport of charged particles across them
Parisová, Martina ; Navrátil, Tomáš ; Šestáková, Ivana ; Kohlíková, E. ; Petr, M.
Because the real bio-membranes and the tranporting processes realized across them are very complicated, the model membranes have been used for elucidation of the basic transporting steps. In the contribution, the different possibilities of characterization, description, and elucidation of the transport processes on the example of some metal ions and theor complexes, i.e., of cadmium, lead, and copper, were presented. It summarizes the results achieved using supported phospholipid model membranes formed on porous membranes and on agar support. Discussed transporting processes of selected ions have been characterized using two electrochemical methods: electrochemical impendance spectrometry (EIS) and voltammetry. The impact of some parameters on these systems and processes was investigated.
Utilization of electrochemical methods in studies of transporting processes across the phospholipid bilayers
Navrátil, Tomáš ; Šestáková, Ivana ; Mareček, Vladimír
This contribution deals with studying and characterization of transporting processes of heavy metals (lead and cadmium) in the form of their free ions and of their complexes with small organic ligands across biological membranes. These membranes are represented by model phospholipid bilayers, formed on the surface a suitable flat support material or in its pores. Phosphatidyl choline and phosphatidyl ethanolamine were used as the membrane building elements. Voltammetry and electrochemical impendance spectrometry (EIS) have been used for characterization of the transporting processes.
Voltammetric determination of anticancer drug flutamide at screen-printed carbon electrodes
Vyskočil, V. ; Navrátil, Tomáš ; Barek, J.
Flutamide, 4-nitro-3-trifluoromethyl-isobutylanilide, is the active component of a synthetic nonsteroidal antiandrogen drug, which is commonly used in the treatment of advanced prostate cancer. In this contribution, optimum conditions have been found vor voltammetric determination of flutamide by DC voltammetry (DCV) and differential pulse voltammetry (DPV) at screen-printed carbon electrodes (SPCEs). Under optimum conditions (Britton-Robinson buffer pH 7.0 - methanol (9:1)), linear calibration curves were measure with limits of quantification 6x10(-7) molL(-1) and 8x10(-7) molL(-1) for DCV at SPCEs, respectively. The newly developed methods were successfully applied to the determination of the drug in pharmaceutical formulation Apo-Flutamide (Eulexin tablets).
Bioimpedance methods to measure somatometric and volumetric changes
Petr, M. ; Kohlíková, E. ; Navrátil, Tomáš
Assessment of human body composition has stimulated the need for an understanding of available methodologies of estimating fat free mass and percent body fat. In our study, we found statistical significant changes of body composition evaluated by multi-frequency bioelectrical analysis in a group of athletes following creatine supplementation. These results are consistent with literature i.e. supplemented creatine effects osmolality of cell´s membranes which leads to increased intracellular water retention. Multi-frequency BIA can be considered to be an accurate and sensitive method for assessment of human body composition.
Elucidation of metabolic pathways affected by creatine supplementation using electrochemical methods
Navrátil, Tomáš ; Kohlíková, E. ; Petr, M. ; Heyrovský, Michael
This contribution deals with successful application of electrochemical methods (voltammetric techniques for analysis of urine and impendance techniques for characterization of body parameters) in investigation metabolic pathways of exogenously supplemented creatine (CR). The electrochemical methods were successfully combined with spectroscopic methods (mostly) based on enzymatic reactions.
Evaluating the accuracy of continuous glucose monitoring by the patient through continuous glucose error grid analysis
Honsová, Š. ; Navrátil, Tomáš
The aim of the study is to compare the difference between the accuracy declared by the producer of continuous glucose determination using the MiniMed Paradigm REAL-Time system with the results achieved by patients in real life. The glucose sensor evaluates the catalytic transformation of glucose (enzyme glucose dehydrogenase) to hydrogen peroxide, the concentration of which is electrochemically evaluated. The accuracy of measurements was determined by Clarke Error Grid Analysis. It can be concluded that in normal glyceamia (4.4 to 10.0 mmol/l) the measurements realized by the parients are more accurate that it is supposed by the producer, opposite to the cases of hypoglycaemia or hyperglycaemia.

National Repository of Grey Literature : 259 records found   beginprevious172 - 181nextend  jump to record:
See also: similar author names
1 Navrátil, T.
4 Navrátil, Tadeáš
Interested in being notified about new results for this query?
Subscribe to the RSS feed.