Original title:
Impact of the Number of Measurements on Result Distortion
Authors:
Kuchařík, Jan ; Šimek, Antonín Document type: Papers
Language:
eng Publisher:
Vysoké učení technické v Brně, Fakulta elektrotechniky a komunikačních technologií Abstract:
This study investigates the distortion of results due to the number of corrosion current measurements. Samples were prepared by pressing and subsequently sintering iron and magnesium powders. The samples were then immersed in an SBL solution at 37 °C. Measurements took place over 23 days. For two samples, measurements were taken each time, while the remaining samples were measured in sequence on their respective days.
Keywords:
corrosion; corrosion current; oxidation; simulated body fluid; solution Host item entry: Proceedings I of the 30st Conference STUDENT EEICT 2024: General papers, ISBN 978-80-214-6231-1, ISSN 2788-1334
Institution: Brno University of Technology
(web)
Document availability information: Fulltext is available in the Brno University of Technology Digital Library. Original record: https://hdl.handle.net/11012/249253