Název: Assessment of the Presence of Hazardous Components in Textile Waste
Autoři: Shtukaturova, Anastasia
Typ dokumentu: Příspěvky z konference
Konference/Akce: Bažant Postgraduate Conference 2024, Prague (CZ), 20240605
Rok: 2024
Jazyk: eng
Abstrakt: An up-flow percolation test was chosen to identify and characterize heavy metals and PFAS constituents in textile waste. Up-flow column percolation tests are used on a laboratory scale to assess the leaching behavior of a hazardous substance from a waste in a given state as a function of time. The test was performed according to the European Technical Standard CEN/TS 14405. Preliminary results showed the following heavy metals in the leachates Al, As, Co, Cr, Cu, Fe, Mn, Pb, Zn and Sb, with Al, Cr, Fe, Mn and Zn being predominant.
Klíčová slova: heavy metals; percolation test; PFAS; textile waste
Zdrojový dokument: Proceedings of Abstracts, ISBN 978-80-86186-32-0
Práva: Dílo je chráněno podle autorského zákona č. 121/2000 Sb.

Instituce: Ústav chemických procesů AV ČR (web)
Původní záznam: https://hdl.handle.net/11104/0354010

Trvalý odkaz NUŠL: http://www.nusl.cz/ntk/nusl-616426

 Záznam vytvořen dne 2024-06-15, naposledy upraven 2024-06-15.


Plný tet:
Pokud se vám dokument nezobrazí v prohlížeči, uložte jej na svůj PC a otevřete jej v příslušném programu.
  • Exportovat ve formátu DC, NUŠL, RIS
  • Sdílet