Original title: Use of Monovalent Copper for Sensitive Detection of Methyl Derivatives of Xanthine
Authors: Navrátil, R. ; Motlova, D. ; Jelen, F. ; Trnková, L.
Document type: Papers
Conference/Event: Moderní Elektrochemické Metody /34./, Jetřichovice (CZ), 2014-05-19 / 2014-05-23
Year: 2014
Language: cze
Abstract: This work is concerned with the electroanalysis of xanthine (Xan) and its methylated derivatives (1-, 3-, 7-, and 9-mXan) on a pencil graphite electrode in the presence of copper ions. The main idea of using copper consists in the in situ formation of the complex Cu(I)-mXan on the electrode surface and improvement of oxidative signals of the corresponding mXan during the detection. Linear sweep voltammetry (LSV) in connection with adsorption stripping techniques was used for the determination of mXan. To enhance the oxidation signals the elimination voltammetric procedure (EVP) was applied.
Keywords: Copper complexes; elimination voltammetry; oxidation; Oxidation of methylxanthines
Host item entry: XXXIV. Moderní elektrochemické metody sborník přednášek, ISBN 978-80-905221-2-1

Institution: Institute of Biophysics AS ČR (web)
Document availability information: Fulltext is available at the institute of the Academy of Sciences.
Original record: http://hdl.handle.net/11104/0297949

Permalink: http://www.nusl.cz/ntk/nusl-396444