Název:
Image analysis in an agitated particle - liquid transparent system
Autoři:
Ditl, P. ; Severa, Miroslav ; Šedivý, V. Typ dokumentu: Příspěvky z konference Konference/Akce: International Congress of Chemical and Process Engineering CHISA 2002 /15./, Prague (CZ), 2002-08-25 / 2002-08-29
Rok:
2002
Jazyk:
eng
Abstrakt: Large tall vessels with a draught tube are used for the mixing of suspensions especially in cases where high homogeneity and heat tranfer are desirable. The article describes flow behaviour of liquid in the vessel with a draught tube. LDA method (Laser Doppler Anemometry) was used for measurement axial velocity profile. The experimental configuration for LDA method was produced by firm DANTEC. Experimental results are compared with numerical simulation and other experiment.
Klíčová slova:
draugh tube; LDA; vessel Číslo projektu: IAA2060907 (CEP) Poskytovatel projektu: GA AV ČR Zdrojový dokument: CHISA 2002: 15th International Congress of Chemical and Process Engineering, ISBN 80-86059-33-2
Instituce: Ústav pro hydrodynamiku AV ČR
(web)
Informace o dostupnosti dokumentu:
Dokument je dostupný v příslušném ústavu Akademie věd ČR. Původní záznam: http://hdl.handle.net/11104/0091843