Home > Conference materials > Papers > Strain sensors based on stress-annealed Co.sub.69./sub.Fe.sub.2./sub.Cr.sub.7./sub.Si.sub.8./sub.B.sub.14./sub. amorphous ribbons
Original title:
Strain sensors based on stress-annealed Co.sub.69./sub.Fe.sub.2./sub.Cr.sub.7./sub.Si.sub.8./sub.B.sub.14./sub. amorphous ribbons
Authors:
Bydžovský, J. ; Kraus, Luděk ; Švec, P. ; Pasquale, M. ; Kollár, M. Document type: Papers Conference/Event: European Conference on Solid-State Transducers /16./, Praha (CZ), 2002-09-15 / 2002-09-18
Year:
2002
Language:
eng Abstract:
Strain sensors based on stress annealed Co.sub.69./sub.Fe.sub.2./sub.Cr.sub.2./sub.Si.sub.8./sub.B.sub.14./sub. amorphous magnetic ribbons were designe. fabricated, and evaluated. Their sensitivity is much more higher compared with resistance gauges, allowing low-price electronic portable equipment for outdoor measurements.
Keywords:
amorphous magnetic ribbons; magnetic sensors; strain sensors Project no.: CEZ:AV0Z1010914 (CEP), SfP-973 649, 1/7609/20, 2/2038/22 Funding provider: NATO, VEGA, VEGA Host item entry: Eurosensors
Institution: Institute of Physics AS ČR
(web)
Document availability information: Fulltext is available at the institute of the Academy of Sciences. Original record: http://hdl.handle.net/11104/0031980