Original title:
Heuristic model in joint EEG-fMRI analysis
Authors:
Janeček, D. Document type: Papers
Language:
eng Publisher:
Vysoké učení technické v Brně, Fakulta elektrotechniky a komunikačních technologií Abstract:
This work deals with the joint EEG-fMRI analysis based on the heuristic model. There is described principle of the heuristic model which assumes that the BOLD (blood oxygen level depend) signal measured by fMRI (functional magnetic resonance imaging) is directly proportional to the spectral shift in the EEG signal. The paper describes algorithm of calculations which was implemented and tested on real data from 22 subjects. The study also monitors effect of different EEG information selection from electrodes of interest (averaging or principal component analysis).
Keywords:
BOLD; heuristic model; HRF; PCA; simultaneous EEG-fMRI; SPM8 Host item entry: Proceedings of the 21st Conference STUDENT EEICT 2015, ISBN 978-80-214-5148-3
Institution: Brno University of Technology
(web)
Document availability information: Fulltext is available in the Brno University of Technology Digital Library. Original record: http://hdl.handle.net/11012/42978