The local road bridge
Janek, Tomáš ; Panáček, Josef (referee) ; Klusáček, Ladislav (advisor)
The bachelor´s thesis deal with a design and assessment a one-span girder bridge. The girder bridge is made of prestressed concrete. The aim of the bachelor´s thesis is to design and assess supporting structure to the specified load.
Design of concrete pedestrian bridge
Hlaváček, Matěj ; Koláček, Jan (referee) ; Zich, Miloš (advisor)
The aim of the thesis is to design a footbridge at the specified location. There have been developed three variants of bridge, which one was selected for detailed design and check. Construction of the footbridge is designed like a frame with fixed foundation piles and hinge attached at the point of connection to the foundation piles. For the calculation of load effects was used Scia Engineer, for the assessment was using MS Excel and manual calculations and drawings drawing in AutoCAD. In this work is done preload design, short- and long-term losses, ultimate and serviceability limit state and reinforcement drawings.
Static analysis of acoustic enclosure
Hándlová, Barbora ; Martinásek, Josef (referee) ; Vlk, Zbyněk (advisor)
The subject of this Bachelor’s thesis is a structural analysis of acoustic enclosure, which is located above production facilities. The enclosure is assembled of elements with a load-bearing skeleton made of steel. It is possible to dismount the enclosure in parts. Computational software RFEM was chosen to model the 3D structure. The aim of this thesis is an assessment of ultimate and serviceability limit state of some selected elements. Some of the results obtained from the RFEM program are verified by hand-done calculation.
The roof structure of the sport hall in Mikulov
Sochorec, Michal ; Barnat, Jan (referee) ; Šmak, Milan (advisor)
Bachelor’s thesis describes design and static assessment of the roof structure of sport hall in Mikulov. Specifically the roofing of the two tennis courts and surrounding stands. Thesis examine several alternatives of design of roof structure like plate girders from glued laminated timber or truss girders made from solid wood. Girders span is 19 m above each tennis court. In the static calculation are assessed individual supporting elements and their connections. The thesis also includes fire resistant report of some elements of roof structure. Static analysis has been accomplished by student version of the SCIA Engineer 14 software.
The footbridge for pedestrians and cyclists in Loštice
Sochorec, Michal ; Bajer, Miroslav (referee) ; Šmak, Milan (advisor)
The Diploma thesis deals with design and static assessment of timber footbridge structural system for pedestrians and cyclist across the Trebuvka river in Lostice on the site of the existing footbridge. Structural system is designed in two alternatives and assessed according to the current standards. Spans of the bridge are 2x18 m and 1x6 m. The main beams are made of glued laminated timber, other parts of the structure are made of timber and steel elements. First alternative is designed as a simple half-through truss beam, second alternative as continuous beam with variable height where the deck is sitting on top of the girders.
The calculation of existing slab bridge
Luliak, Ondřej ; Nečas,, Radim (referee) ; Klusáček, Ladislav (advisor)
Bachelor´s thesis is concrended with resistance simple bearing slab bridges. The main focuse is comparison diferents in resistance calculated according to ČSN valid between 1915 and 1935 compare with calculate resistance according to ČSN EN which is valid now. Next part is concrended serviceability limit state.
Bridge across the river Svitava
Mičánek, Ondřej ; Koláček, Jan (referee) ; Nečas, Radim (advisor)
The subject of this bachelor thesis is the design of superstructure of footbridge over the Svitava river. The design is processed by three options. The chosen option is designed as an arch bridge with a lower prestressed bridge deck, suspended on a steel arch. Bridge is designed as perpendicular, simply placed on the outer supports. The lenght of of the superstructure is 46,8 m. and the lenght of the bridging is 44 m. The steel arch is designed as a second stage parabola with a 6 m stiffness. The calculation of load effects was done by SCIA Engineer 2017 software. Design and structural assessment reports are designed according to the valid standards and regulations.
Prestressed slab structure using SFRC
Herka, Martin ; Panáček, Josef (referee) ; Klusáček, Ladislav (advisor)
This thesis deals with the design and solution of a slab bridge structure. There are two varies considered - prestressed concrete structure and prestressed structure using steel fiber reinforced concrete. The aim of the thesis is to assess a contribution to application of steel fiber reinforced concrete in serviceability limit state and ultimate limit state. At the end of thesis is an evaluation of possibility to design this type of structure from prestressed steel fiber reinforced concrete.
Salesian Center
Martinek, Ivo ; Perla, Jan (referee) ; Švaříčková, Ivana (advisor)
This final thesis is focused on a reinforcement design and check of selected reinforced concrete structure parts of a church building. A spatial model loaded with dead and live loads is designed in order to carry out a structural analysis in SCIA Engineer software. Serviceability limit state and fire resistance are then checked for some selected load-bearing elements. The drawings are also included in this work.
Space structure of industry building object
Pelikán, Adam ; Švaříčková,, Ivana (referee) ; Šimůnek, Petr (advisor)
The subject of this project is the structure of the storage hall which is made of reinforced concrete. It is designed as precast frame (span of 18m), founded on pocket footings. The roof deck (non-rigid) consists of ribbed slabs. The cladding is made of sandwich panels (reinforced concrete and isolation) layed on foundation beam. The design is focused on the single typical frame. Roof girder, column and pocket footing are designed. Designed life of the structure is 50 years.