Název: Comparison Of Methods For Measuring Shockduration
Autoři: Kunz, Jan
Typ dokumentu: Příspěvky z konference
Jazyk: eng
Nakladatel: Vysoké učení technické v Brně, Fakulta elektrotechniky a komunikačních technologií
Abstrakt: This paper compares a linear interpolation, an interval and a sine interpolation method for measuring mechanical shock duration. All methods are analysed to find differences and limitations. Then methods are tested on simulated and real shock shapes to confirm analysis results. We discovered that the sine interpolation method is very robust to noise, however is sensitive to shock shape changes. The linear interpolation method accuracy is influenced by noise, however this method works also on high noise level (SNR = 0 dB). The interval method provides consistent results up to some noise level (SNR > 10 dB), where it stops working.
Klíčová slova: duration measurement; half-sine shock; interval method; linear interpolation method; mechanical shock; sine interpolation method
Zdrojový dokument: Proceedings of the 23st Conference STUDENT EEICT 2017, ISBN 978-80-214-5496-5

Instituce: Vysoké učení technické v Brně (web)
Informace o dostupnosti dokumentu: Plný text je dostupný v Digitální knihovně VUT.
Původní záznam: http://hdl.handle.net/11012/187141

Trvalý odkaz NUŠL: http://www.nusl.cz/ntk/nusl-414801


Záznam je zařazen do těchto sbírek:
Školství > Veřejné vysoké školy > Vysoké učení technické v Brně
Konferenční materiály > Příspěvky z konference
 Záznam vytvořen dne 2020-07-11, naposledy upraven 2021-08-22.


Není přiložen dokument
  • Exportovat ve formátu DC, NUŠL, RIS
  • Sdílet