National Repository of Grey Literature 4 records found  Search took 0.00 seconds. 
Individual ....
Tomeček, David ; Kocna, Petr (advisor) ; Průša, Richard (referee)
13 C-MTG breath tests are used for exocrine pancreas diagnostics. It is a quite expansive test and its usage has never been tested in clinical practice in long time horizon. This study is engaged in pre-analytical phase and contains a group of 4 people who were tested for 6 months and this is the first study ever that has been proceeded in a long time horizon. The half-year profile of these 4 people showed that some of those results are spread of tens percents against its average. The test of CO2 stability showed that the value of CO2 is independent on the temperature which the breath bag is stored in. Its concentration was same for the time of 7 days. Now we can say that the breath bags are insensitive in case of transporting and storage. The question is, why the value of delta 13 C/12 C changed. The results of this study point on fact that values of cumulative dosage recovery of these 4 people did change.
Final report of the project - Secure erasing memory chips using electromagnetic pulse
Fitl, Přemysl ; Vrňata, M. ; Fišer, L. ; Novotný, Michal ; Scholtz, V. ; Vlček, J. ; Tomeček, D.
The subject of this contractual research was the theoretical analysis and the mathematical model of the problem of electromagnetic pulse penetration and involvement of storage function of the memory chips. The report includes description of the experimental preparation memory chip, methodology of memory media testing, experiment shielding, software scanning of the memory chip, EMP generation, EMP intensity measurement. \nSummary of results of experiments of EMP influence on the memory media.\nA comprehensive research report was handed over to NUKIB representatives on 31 May 2018. NUKIB representatives confirmed receipt of the report. \nDefense of the project results took place on 27.6.2018 in the NUKIB building. Project goals were fulfilled. The agreed amount was invoiced for this report.\n\n
Secure erasing memory chips using electromagnetic pulse - phase 1
Fitl, Přemysl ; Vrňata, M. ; Fišer, L. ; Novotný, Michal ; Scholtz, V. ; Vlček, J. ; Tomeček, D.
The subject of this contractual research was to perform study of technologies and principles of flash memories currently available on the market. The research report focuses on technological advancements in their development, the readability of stored / deleted data by available laboratory techniques, and the interaction of these memories with the electromagnetic pulse.\nThe outcome was handed over to NUKIB representatives on 29 March 2018. \nThe project was fulfilled, the agreed amount was invoiced for this report.\n\n\n
Individual ....
Tomeček, David ; Kocna, Petr (advisor) ; Průša, Richard (referee)
13 C-MTG breath tests are used for exocrine pancreas diagnostics. It is a quite expansive test and its usage has never been tested in clinical practice in long time horizon. This study is engaged in pre-analytical phase and contains a group of 4 people who were tested for 6 months and this is the first study ever that has been proceeded in a long time horizon. The half-year profile of these 4 people showed that some of those results are spread of tens percents against its average. The test of CO2 stability showed that the value of CO2 is independent on the temperature which the breath bag is stored in. Its concentration was same for the time of 7 days. Now we can say that the breath bags are insensitive in case of transporting and storage. The question is, why the value of delta 13 C/12 C changed. The results of this study point on fact that values of cumulative dosage recovery of these 4 people did change.

See also: similar author names
2 Tomeček, David
Interested in being notified about new results for this query?
Subscribe to the RSS feed.