National Repository of Grey Literature 10 records found  Search took 0.01 seconds. 
Air-conditioning of Department store
Chorý, Vojtěch ; Rubina,, Aleš (referee) ; Rubinová, Olga (advisor)
The topic of this bachelor thesis is design of air-condition equipment for veterinary clinic. The clinic is located on the first floor of a multifunctional building in Brno city. For design purposes is used warm-air heating, air-conditioning and forced air-replacement. The theoretical part is focused on clean room issue. The Project part contains a project documentation for realization of two air-conditioning equipment. The first air-conditioning equipment is designed for warm-air heating and air-conditionig of clean rooms. The second air-conditioning equipment provides forcer air-replacement of the clinic.
Air condition of family house
Kuráňová, Helena ; Hirš, Jiří (referee) ; Uher, Pavel (advisor)
The topic of the bachelor thesis is the design of ventilation system in a family house with an indoor pool. In my bachelor thesis I deal with ventilation and dehumidification of the pool area, ventilation of the living rooms in the family house and ventilation of the garages in order to fulfill the requirements for indoor microclimate of the building.
Aircondition of club
Urban, Ondřej ; Rubinová, Olga (referee) ; Uher, Pavel (advisor)
This bachelor´s thesis deals with the air-conditioning of a club. Its design focuses specifically on sanitary facilities and sports hall. The project of the bachelor thesis covers ventilation units, including heat recovery from a sport hall and outline of displacement ventilation.
Design of air conditioning system of a flat
Vrbický, Jiří ; Zerzaňová, Alena (referee) ; Hejčík, Jiří (advisor)
The diploma thesis is consisting of theoretic part, which deal with used ventilating systems, ways of waste heat recovery and describe basic types of air-conditioning systems. Following part attend to design of ventilating system and multi-split air-conditioning system for flat. Part of design of ventilation system is calculation of noise levels in rooms. Air-conditioner design is based on calculation of thermal stress. Annual demand of cold and heat demand are calculated using TRANSYS software. Design documentation is part of the diploma thesis.
Ventilation and heating in a retrofitted two-story family house
Minařík, Petr ; Štětina, Josef (referee) ; Charvát, Pavel (advisor)
The thesis deals with the calculation of the design heat load of a reconstructed family house and the design of both the space heating system and the balanced ventilation system for the house. The determination of the design heat load was performed according to ČSN EN 12831 technical standard. A low-temperature hydronic heating system was chosen for space heating of the house. The thesis describes the design of the system including calculations and the technical drawings. A heat source for the heating system was chosen with regard to the requirements of the investor. A mechanical ventilation system with heat recovery was proposed for house ventilation. The thesis contains the design of the ventilation system including calculations and the technical drawings.
Air condition of family house
Kuráňová, Helena ; Hirš, Jiří (referee) ; Uher, Pavel (advisor)
The topic of the bachelor thesis is the design of ventilation system in a family house with an indoor pool. In my bachelor thesis I deal with ventilation and dehumidification of the pool area, ventilation of the living rooms in the family house and ventilation of the garages in order to fulfill the requirements for indoor microclimate of the building.
Ventilation and heating in a retrofitted two-story family house
Minařík, Petr ; Štětina, Josef (referee) ; Charvát, Pavel (advisor)
The thesis deals with the calculation of the design heat load of a reconstructed family house and the design of both the space heating system and the balanced ventilation system for the house. The determination of the design heat load was performed according to ČSN EN 12831 technical standard. A low-temperature hydronic heating system was chosen for space heating of the house. The thesis describes the design of the system including calculations and the technical drawings. A heat source for the heating system was chosen with regard to the requirements of the investor. A mechanical ventilation system with heat recovery was proposed for house ventilation. The thesis contains the design of the ventilation system including calculations and the technical drawings.
Design of air conditioning system of a flat
Vrbický, Jiří ; Zerzaňová, Alena (referee) ; Hejčík, Jiří (advisor)
The diploma thesis is consisting of theoretic part, which deal with used ventilating systems, ways of waste heat recovery and describe basic types of air-conditioning systems. Following part attend to design of ventilating system and multi-split air-conditioning system for flat. Part of design of ventilation system is calculation of noise levels in rooms. Air-conditioner design is based on calculation of thermal stress. Annual demand of cold and heat demand are calculated using TRANSYS software. Design documentation is part of the diploma thesis.
Aircondition of club
Urban, Ondřej ; Rubinová, Olga (referee) ; Uher, Pavel (advisor)
This bachelor´s thesis deals with the air-conditioning of a club. Its design focuses specifically on sanitary facilities and sports hall. The project of the bachelor thesis covers ventilation units, including heat recovery from a sport hall and outline of displacement ventilation.
Air-conditioning of Department store
Chorý, Vojtěch ; Rubina,, Aleš (referee) ; Rubinová, Olga (advisor)
The topic of this bachelor thesis is design of air-condition equipment for veterinary clinic. The clinic is located on the first floor of a multifunctional building in Brno city. For design purposes is used warm-air heating, air-conditioning and forced air-replacement. The theoretical part is focused on clean room issue. The Project part contains a project documentation for realization of two air-conditioning equipment. The first air-conditioning equipment is designed for warm-air heating and air-conditionig of clean rooms. The second air-conditioning equipment provides forcer air-replacement of the clinic.

Interested in being notified about new results for this query?
Subscribe to the RSS feed.