National Repository of Grey Literature 12 records found  1 - 10next  jump to record: Search took 0.00 seconds. 
Shortwave power amplifier
Fiala, Roman ; Vařacha, František (referee) ; Prokeš, Aleš (advisor)
This master’s thesis describes RF power amplifier design. The designed amplifier has been built. The first three chapters outline basics about radio frequency amplifiers. The basic theory needed for amplifier implementation is also described there. In the fourth chapter the power amplifier is designed. The design is based on the theoretical knowledge. Complete amplifier contains RF preamplifier, power amplifier and filters. The OrCAD PSpice, Ansoft Designer SV and EAGLE programs have been used for the design and verification of some sections of circuits. Measurement results of the built amplifier are in the fifth chapter. This thesis contains also the draft for laboratory exercise.
Ultrasound blood flow detector
Kameníček, Robert ; Dlouhý, Jiří (referee) ; Rozman, Jiří (advisor)
My master’s thesis deals with methods of measuring the ultrasonic blood flow blood vessel with a detailed focus on Doppler ultrasound systems, which find application in the diagnosis of superficial vascular and obstetrics. The thesis is described a proposal indicating polydirectional Doppler system with a continuous carrier wave frequency of 4 MHz, the intensity of ultrasound 100 mW/cm2 and diameter D-shaped transducers 8 mm. As a result, the indicator will be able to measure blood flow velocity in the range of 5-40 cm/s, which appears to 3.5 digit display. After describing important theoretical assumptions, the work pays block diagram indicator. Furthermore, it examines the various functional blocks on the requirements imposed on them. It looks at the options of each functional block, and finally describes the implementation of the selected option and including peripheral solutions. Great attention is paid to the power of the indicator, where the power supply will be used 9 V battery. Create a symmetric voltage for operate amplifier and other auxiliary voltage will procure DC/DC converters. In conclusion, the work is located around the perimeter solutions indicator. The following draft for the production of double-sided PCB, its installation and a list of elements. The outcome of the thesis is complete documentation for the implementation of an indicator of blood flow, which allows us to obtain information on throughput vessels, especially the lower and upper limbs.
Shortwave power amplifier
Kufa, Jan ; Vařacha, František (referee) ; Prokeš, Aleš (advisor)
The aim of the master´s thesis is to create a high-frequency amplifier with switching power amplifier classes among classes A, B, C with output power of 10 W. The amplifier operates at frequency from 3.5 MHz to 14 MHz. Master´s thesis includes also theoretical analysis, design of lowpass filter and amplifiers and their simulation, mechanical realization and measured parameters of the amplifier.
Doppler blood flow indicator
Böhm, Richard ; Bubník, Karel (referee) ; Rozman, Jiří (advisor)
This bachelor‘s thesis deals with literature search of basis of ultrasonic and Doppler methods of measuring blood flow velocity. It also deals with the evaluation of Doppler signals and with the individual functional system blocks, with the indicator of blood flow with the operating frequency of 4 MHz, with the generated ultrasonic intensity of 100 mW/cm2 and with the average transmitting changer in shape of D = 8 mm. Furthermore, experimental verification of individual system components is included.
Solid State Power Amplifier for the L-Band
Pecen, Vojtěch ; Vondra, Vlastimil (referee) ; Kasal, Miroslav (advisor)
The goal of this diploma's thesis is to create a design of a two stages amplifier working in a band reserved for the secondary surveillance radar at the frequency of 1090 MHz. Output power of the amplifier should be 20 W and efficiency should be as high as possible. Because of this the second stage is designed in class C. Contents of this diploma's thesis include a theoretical analysis, simulations of the amplifier parameters, comparison of the Ansys Designer and AWR Microwave Office simulation programs and design of both stages of the amplifier, followed by a comparison of the measured parameters with the simulations.
Doppler blood flow indicator
Byrtus, David ; Čech, Petr (referee) ; Rozman, Jiří (advisor)
Bachelor´s thesis deals with methods for measuring Doppler velocity and blood flow in non-directional system with unmodulated carrier wave, system design indicator of blood flow for a frequency of 4 MHz ultrasound intensity of 100 mW/cm2 and evaluating methods of Doppler signals.
Solid State Power Amplifier for the L-Band
Pecen, Vojtěch ; Vondra, Vlastimil (referee) ; Kasal, Miroslav (advisor)
The goal of this diploma's thesis is to create a design of a two stages amplifier working in a band reserved for the secondary surveillance radar at the frequency of 1090 MHz. Output power of the amplifier should be 20 W and efficiency should be as high as possible. Because of this the second stage is designed in class C. Contents of this diploma's thesis include a theoretical analysis, simulations of the amplifier parameters, comparison of the Ansys Designer and AWR Microwave Office simulation programs and design of both stages of the amplifier, followed by a comparison of the measured parameters with the simulations.
Doppler blood flow indicator
Böhm, Richard ; Bubník, Karel (referee) ; Rozman, Jiří (advisor)
This bachelor‘s thesis deals with literature search of basis of ultrasonic and Doppler methods of measuring blood flow velocity. It also deals with the evaluation of Doppler signals and with the individual functional system blocks, with the indicator of blood flow with the operating frequency of 4 MHz, with the generated ultrasonic intensity of 100 mW/cm2 and with the average transmitting changer in shape of D = 8 mm. Furthermore, experimental verification of individual system components is included.
Doppler blood flow indicator
Byrtus, David ; Čech, Petr (referee) ; Rozman, Jiří (advisor)
Bachelor´s thesis deals with methods for measuring Doppler velocity and blood flow in non-directional system with unmodulated carrier wave, system design indicator of blood flow for a frequency of 4 MHz ultrasound intensity of 100 mW/cm2 and evaluating methods of Doppler signals.
Shortwave power amplifier
Fiala, Roman ; Vařacha, František (referee) ; Prokeš, Aleš (advisor)
This master’s thesis describes RF power amplifier design. The designed amplifier has been built. The first three chapters outline basics about radio frequency amplifiers. The basic theory needed for amplifier implementation is also described there. In the fourth chapter the power amplifier is designed. The design is based on the theoretical knowledge. Complete amplifier contains RF preamplifier, power amplifier and filters. The OrCAD PSpice, Ansoft Designer SV and EAGLE programs have been used for the design and verification of some sections of circuits. Measurement results of the built amplifier are in the fifth chapter. This thesis contains also the draft for laboratory exercise.

National Repository of Grey Literature : 12 records found   1 - 10next  jump to record:
Interested in being notified about new results for this query?
Subscribe to the RSS feed.