National Repository of Grey Literature 6 records found  Search took 0.01 seconds. 
ECG Signal Distortion Measures
Požár, Pavel ; Kozumplík, Jiří (referee) ; Vítek, Martin (advisor)
This master's thesis deals with electrocardiogram and its distortion, which causes errors, due to which a doctor can make a wrong diagnosis. In the theoretical part electrocardiogram is briefly described, further theory of wavelet transform, introduction to the signal compression and some information about ECG delineation. Methods used for the signal evaluation and therefore determination of the distortion size are described in the main theoretical part. This thesis contains known methods and also a method of own design based on the ECG delineation. Some of the described methods are checked in the practical part. These methods are tested for two different compression algorithms, which cause various distortion. In the final part distortion was tested on the influence on setting the wrong diagnosis.
Automatic delineation of ECG signals
Olšanská, Eva ; Kozumplík, Jiří (referee) ; Vítek, Martin (advisor)
This bachelor´s thesis deals with the delineation of ECG signals. The aim of this bachelor´s thesis is to become familiar with ECG delineation and realize one chosen delineation method in Matlab. The delineation algorithm was tested on a CSE database. The theoretical part of the work describes methods of QRS complex detection and ECG delineation.
Automatic delineation of ECG signals
Vítek, Martin ; Tyšler, Milan (referee) ; Halámek,, Josef (referee) ; Kozumplík, Jiří (advisor)
This dissertation deals with QRS complex detection and ECG delineation. The theoretical part of the work describes basics of electrocardiography, QRS detection approaches, ECG delineation approaches, the standard CSE database and the wavelet transform theory. The practical part of the work describes designed methods of QRS complex detection and ECG delineation. The designed methods are based on a continuous wavelet transform, appropriate scales, appropriate mother wavelet, cluster analysis and leads transformation. The introduced algorithms were evaluated on the standard CSE database. The obtained results are better, than directly comparable results of other methods and accomplished given database criteria. The robustness of designed algorithms was successfully tested on CSE database signals modified by compression and filtering. The proposed ECG delineation algorithm was successfully used as a tool for evaluation of diagnostic distortion of ECG signals modified by compression.
Automatic delineation of ECG signals
Olšanská, Eva ; Kozumplík, Jiří (referee) ; Vítek, Martin (advisor)
This bachelor´s thesis deals with the delineation of ECG signals. The aim of this bachelor´s thesis is to become familiar with ECG delineation and realize one chosen delineation method in Matlab. The delineation algorithm was tested on a CSE database. The theoretical part of the work describes methods of QRS complex detection and ECG delineation.
Automatic delineation of ECG signals
Vítek, Martin ; Tyšler, Milan (referee) ; Halámek,, Josef (referee) ; Kozumplík, Jiří (advisor)
This dissertation deals with QRS complex detection and ECG delineation. The theoretical part of the work describes basics of electrocardiography, QRS detection approaches, ECG delineation approaches, the standard CSE database and the wavelet transform theory. The practical part of the work describes designed methods of QRS complex detection and ECG delineation. The designed methods are based on a continuous wavelet transform, appropriate scales, appropriate mother wavelet, cluster analysis and leads transformation. The introduced algorithms were evaluated on the standard CSE database. The obtained results are better, than directly comparable results of other methods and accomplished given database criteria. The robustness of designed algorithms was successfully tested on CSE database signals modified by compression and filtering. The proposed ECG delineation algorithm was successfully used as a tool for evaluation of diagnostic distortion of ECG signals modified by compression.
ECG Signal Distortion Measures
Požár, Pavel ; Kozumplík, Jiří (referee) ; Vítek, Martin (advisor)
This master's thesis deals with electrocardiogram and its distortion, which causes errors, due to which a doctor can make a wrong diagnosis. In the theoretical part electrocardiogram is briefly described, further theory of wavelet transform, introduction to the signal compression and some information about ECG delineation. Methods used for the signal evaluation and therefore determination of the distortion size are described in the main theoretical part. This thesis contains known methods and also a method of own design based on the ECG delineation. Some of the described methods are checked in the practical part. These methods are tested for two different compression algorithms, which cause various distortion. In the final part distortion was tested on the influence on setting the wrong diagnosis.

Interested in being notified about new results for this query?
Subscribe to the RSS feed.