National Repository of Grey Literature 8 records found  Search took 0.01 seconds. 
Diaphragm discharge in organic dye solutions with focus on electrolytic decomposition
Davidová, Jaroslava ; Brablec, Antonín (referee) ; Kozáková, Zdenka (advisor)
This Diploma thesis is focused on physical and chemical effects which contribute to the decomposition of organic dyes by diaphragm discharge generated in water solutions. Due to the application of DC high voltage source in continuous regime, there is an effect of electrolysis contributing to the dye decomposition by diaphragm discharge. The aim of this work was to find out when the electrolysis is running (or when is the moment of discharge breakdown) and which factors influence the breakdown. The other goal was decomposition of selected textile and food organic dyes by electrolysis itself. In the theoretical part, theory about creation of electrical discharges in aqueous solutions is noted and various types of underwater discharges are described. Background researches about underwater electrical discharges used in the world are mentioned as well as the use of diaphragm discharges and various ways how to remove organic dyes from wastewater. Finally, theories of electrolysis, UV-VIS spectroscopy and basis of other analytical methods useful for detection of organic molecules are described. Experimental part is oriented to experiment procedure which was carried out in a reactor with separated electrode areas. Separation was made by dielectric diaphragm with a pinhole in the centre. Its initial diameter was 0.4 mm. Used chemicals and course of experiments are described in this part, too. First, the breakdown moment in the reactor was investigated (i. e. determination, when only electrolysis was operating) by formation of hydrogen peroxide and measurement of dynamic (time resolved) electrical characteristics. Next, decomposition of selected dyes by electrolysis was carried out. As the decomposition was related to decolorization of the solution, UV-VIS spectroscopy in the range of 350–700 nm was used for determination of dye concentration. Next part focused on results presents various factors which had an effect on breakdown of diaphragm discharge. These factors are kind of used electrolyte, initial conductivity of solution, kind of dye, temperature of solution and type of reactor (or solution volume). From the result, the most important factor is initial solution conductivity. After the determination of the breakdown moment, the electrolysis of organic dyes was performed. The applied current was 10 mA, initial conductivity was 500 µS/cm and used electrolyte was NaCl. Moreover comparison of dye decomposition in dependence on the different applied power was realized. From this comparison one can assume, there is no significant contribution of electrolysis (the efficiency is approximately 15 %) to the diaphragm discharge in aqueous solution.
Charakterizace tenkovrstvých elektroluminiscenčních součástek
Ahmed, Mustafa M. Abdalla ; Hrabovský, Miroslav (referee) ; Tománek, Pavel (advisor)
Jádrem této disertační práce bylo studovat optické a elektrické charakteristiky tenkovrstvých elektroluminiscenčních součástek řízených střídavým proudem (ACTFEL) a zejména vliv procesu stárnutí luminiforů na jejich optické a elektrické vlastnosti. Cílem této studie měl být příspěvek ke zvýšení celkové účinnosti luminoforů, vyjádřené pomocí jasu, účinnosti a stability. Vzhledem k tomu, že současnou dominantní technologií plochých obrazovek je LCD, musí se další alternativní technologie plošných displejů porovnávat s LCD. Výhodou ACTFEL displejů proti LCD je lepší rozlišení, větší teplotní rozsah činnosti, větší čtecí úhel, či možnost čtení při mnohem vyšší intenzitě pozadí. Na druhou stranu je jejich nevýhodou vyšší energetická náročnost, problém s odpovídající barevností tří základních barev a podstatně vyšší napětí nutné pro činnost displeje. K dosažení tohoto cíle jsme provedli optická, elektrická a optoelektrická měření ACTFEL struktur a ZnS:Mn luminoforů. Navíc jsme studovali vliv dotování vrstvy pomocí KCl na chování mikrostruktury a na elektroluminiscenční vlastnosti (zejména na jas a světelnou účinnost) ZnS:Mn luminoforů. Provedli jsme i některá, ne zcela obvyklá, měření ACTFEL součástek. Vypočítali jsme i rozptylový poměr nabitých barevných center a simulovali transportní charakteristiky v ACTFEL součástkách. Studovali jsme vliv stárnutí dvou typů ZnS:Mn luminoforů (s vrstvou napařenou či získanou pomocí epitaxe atomových vrstev) monitorováním závislostí svítivost-napětí (L-V), velikost vnitřního náboje - elektrické pole luminoforu (Q-Fp) a kapacitance-napětí (C-V) ve zvolených časových intervalech v průběhu stárnutí. Provedli jsme krátkodobá i dlouhodobá měření a pokusili jsme se i o vizualizaci struktury luminoforu se subvlnovým rozlišením pomocí optického rastrovacího mikroskopu pracujícího v blízkém poli (SNOM). Na praktickém případu zeleného Zn2GeO4:Mn (2% Mn) ACTFEL displeje, pracujícího při 50 Hz, jsme také studovali stabilitu svítivosti pomocí měření závislosti svítivosti na napětí (L-V) a světelné účinnosti na napětí (eta-V). Přitom byl zhodnocen význam těchto charakteristik. Nezanedbatelnou a neoddělitelnou součástí této práce je i její pedagogický aspekt. Předložený text by mohl být využit i jako učebnice pro studenty na mé univerzitě v Lybii.
Plasma diagnostics of electric discharges generated in selected configurations in liquids
Vašíček, Michal ; Bartlová, Milada (referee) ; Kozáková, Zdenka (advisor)
My diploma thesis is focused on a comparison of direct-current and high frequency (15-80 kHz) electric discharge, which generates non-thermal plasma in water solution of sodium chloride. Mainly current-voltage and Lissajous charts are discussed in the first part of this thesis. These charts describe different discharge phases: electrolysis, bubble formation, discharge breakdown and discharge regular operation in a pin-hole of a dielectric barrier. Influence of frequency, electrolyte conductivity, thickness of the diaphragm (or length of the capillary) and pin-hole diameter on discharge breakdown and bubble generation was studied, too. Measurements were realized in a polycarbonate reactor with total volume of 110 ml, which was divided by a changeable polyacetal insulating wall. This wall divided the reactor into two approximately equal spaces with one stainless steel planar electrode in each part. The Shapal-MTM ceramic discs (thickness of 0.3–1.5 mm and diameter of the central pin-hole of 0.3-0.9 mm) were mounted in the centre of the insulating wall. Initial conductivity of sodium chloride solution was chosen within the interval of 100900 S/cm. The second part of my thesis compares an influence of the direct-current (DC) and high frequency (HF) power sources on physical solution properties (conductivity, pH and temperature) and generation of hydrogen peroxide. A plasma reactor with total volume of 4 l and with mixing set up was divided into two equal spaces with one planar platinum electrode in each part. Diaphragm with thickness of 0.6 mm and pin-hole diameter of 0.6 mm was installed in the middle of the separating wall. Experiment was held at discharge operation of 45 W for 40 minutes with both power sources. Detection of hydrogen peroxide was realised by using a titanium reagent forming a yellow complex, which was analysed by absorption spectroscopy. If HF discharge power is plotted as a function of applied frequency, exponential decrease of frequency with increasing power can be observed. Higher breakdown voltage is necessary for thicker dielectric barriers, on the other hand for bigger diameter of the pin-hole lower breakdown voltage and higher power is needed in DC as well as in HF regime. Breakdown voltage is decreased by the increasing conductivity in both regimes; due to more charge carriers in the higher conductivity lower breakdown voltage is needed. However frequency in HF regime and DC discharge power increases. HF discharge power is decreased by the increasing conductivity. Solution conductivity and temperature are increased by initial conductivity value in both discharge regimes. Solution pH drops to acidic conditions when HF or DC positive regime is applied due to the generation of reactive species and electrolysis (in DC regime). However solution becomes alkaline when DC negative regime is applied. Concentration of hydrogen peroxide is produced linearly when HF or DC negative regime is applied and it depends on initial solution conductivity.
Diagnostics of plasma generated in mixtures of water and alcohols
Adámková, Barbora ; Slavíček, Pavel (referee) ; Kozáková, Zdenka (advisor)
This diploma thesis is aimed to the corona-like discharge in solutions of alcohols, specifically in ethanol, methanol, glycerol, butanol and isopropyl alcohol. The electric discharge was diagnosed by two methods. The first method was the measuring of electrical characteristics. Current-voltage characteristics were constructed from the measured average values of voltage and current. The breakdown voltages were determined from the current-voltage characteristics. The breakdown voltages of the individual alcohol solutions were dependent on the alcohol concentration, polarity of the electrodes in the reactor and solution conductivity. The breakdown voltage was determined for solutions of butanol, glycerol and isopropyl alcohol with a concentration of 20 vol. % and conductivity of 200 µS. The highest value of the breakdown voltage was determined for solution of glycerol at 580 V. The lowest voltage at which the discharge was observed was estimated for butanol (320 V), but due to the limited miscibility with water this value is inaccurate, and therefore in the second part of experiment butanol was not used. Alcohol series was supplemented with methanol. The second diagnostic method was the proton ionization mass spectrometry with the time of flight analyzer. The products formed in the reactor due to the plasma discharge were identified from the mass spectrum. Mostly, aliphatic hydrocarbons and their radicals were detected. The amount of products was observed in the dependence on the changing experimental conditions: alcohol concentration in the solution, the polarity of the electrodes in the reactor and the duration of the discharge. Only a small amount of compounds were detected in methanol. However, more molecules were formed with the increasing carbon chain in the alcohol molecule. More compounds were also detected with the increasing alcohol concentration and in case of the negative polarity of the main electrode. The formation of acetaldehyde as a typical discharge product was studied in details. Its production in time was observed and the reaction pathways of its formation in the ethanol solution were suggested.
Diagnostics of plasma generated in mixtures of water and alcohols
Adámková, Barbora ; Slavíček, Pavel (referee) ; Kozáková, Zdenka (advisor)
This diploma thesis is aimed to the corona-like discharge in solutions of alcohols, specifically in ethanol, methanol, glycerol, butanol and isopropyl alcohol. The electric discharge was diagnosed by two methods. The first method was the measuring of electrical characteristics. Current-voltage characteristics were constructed from the measured average values of voltage and current. The breakdown voltages were determined from the current-voltage characteristics. The breakdown voltages of the individual alcohol solutions were dependent on the alcohol concentration, polarity of the electrodes in the reactor and solution conductivity. The breakdown voltage was determined for solutions of butanol, glycerol and isopropyl alcohol with a concentration of 20 vol. % and conductivity of 200 µS. The highest value of the breakdown voltage was determined for solution of glycerol at 580 V. The lowest voltage at which the discharge was observed was estimated for butanol (320 V), but due to the limited miscibility with water this value is inaccurate, and therefore in the second part of experiment butanol was not used. Alcohol series was supplemented with methanol. The second diagnostic method was the proton ionization mass spectrometry with the time of flight analyzer. The products formed in the reactor due to the plasma discharge were identified from the mass spectrum. Mostly, aliphatic hydrocarbons and their radicals were detected. The amount of products was observed in the dependence on the changing experimental conditions: alcohol concentration in the solution, the polarity of the electrodes in the reactor and the duration of the discharge. Only a small amount of compounds were detected in methanol. However, more molecules were formed with the increasing carbon chain in the alcohol molecule. More compounds were also detected with the increasing alcohol concentration and in case of the negative polarity of the main electrode. The formation of acetaldehyde as a typical discharge product was studied in details. Its production in time was observed and the reaction pathways of its formation in the ethanol solution were suggested.
Charakterizace tenkovrstvých elektroluminiscenčních součástek
Ahmed, Mustafa M. Abdalla ; Hrabovský, Miroslav (referee) ; Tománek, Pavel (advisor)
Jádrem této disertační práce bylo studovat optické a elektrické charakteristiky tenkovrstvých elektroluminiscenčních součástek řízených střídavým proudem (ACTFEL) a zejména vliv procesu stárnutí luminiforů na jejich optické a elektrické vlastnosti. Cílem této studie měl být příspěvek ke zvýšení celkové účinnosti luminoforů, vyjádřené pomocí jasu, účinnosti a stability. Vzhledem k tomu, že současnou dominantní technologií plochých obrazovek je LCD, musí se další alternativní technologie plošných displejů porovnávat s LCD. Výhodou ACTFEL displejů proti LCD je lepší rozlišení, větší teplotní rozsah činnosti, větší čtecí úhel, či možnost čtení při mnohem vyšší intenzitě pozadí. Na druhou stranu je jejich nevýhodou vyšší energetická náročnost, problém s odpovídající barevností tří základních barev a podstatně vyšší napětí nutné pro činnost displeje. K dosažení tohoto cíle jsme provedli optická, elektrická a optoelektrická měření ACTFEL struktur a ZnS:Mn luminoforů. Navíc jsme studovali vliv dotování vrstvy pomocí KCl na chování mikrostruktury a na elektroluminiscenční vlastnosti (zejména na jas a světelnou účinnost) ZnS:Mn luminoforů. Provedli jsme i některá, ne zcela obvyklá, měření ACTFEL součástek. Vypočítali jsme i rozptylový poměr nabitých barevných center a simulovali transportní charakteristiky v ACTFEL součástkách. Studovali jsme vliv stárnutí dvou typů ZnS:Mn luminoforů (s vrstvou napařenou či získanou pomocí epitaxe atomových vrstev) monitorováním závislostí svítivost-napětí (L-V), velikost vnitřního náboje - elektrické pole luminoforu (Q-Fp) a kapacitance-napětí (C-V) ve zvolených časových intervalech v průběhu stárnutí. Provedli jsme krátkodobá i dlouhodobá měření a pokusili jsme se i o vizualizaci struktury luminoforu se subvlnovým rozlišením pomocí optického rastrovacího mikroskopu pracujícího v blízkém poli (SNOM). Na praktickém případu zeleného Zn2GeO4:Mn (2% Mn) ACTFEL displeje, pracujícího při 50 Hz, jsme také studovali stabilitu svítivosti pomocí měření závislosti svítivosti na napětí (L-V) a světelné účinnosti na napětí (eta-V). Přitom byl zhodnocen význam těchto charakteristik. Nezanedbatelnou a neoddělitelnou součástí této práce je i její pedagogický aspekt. Předložený text by mohl být využit i jako učebnice pro studenty na mé univerzitě v Lybii.
Plasma diagnostics of electric discharges generated in selected configurations in liquids
Vašíček, Michal ; Bartlová, Milada (referee) ; Kozáková, Zdenka (advisor)
My diploma thesis is focused on a comparison of direct-current and high frequency (15-80 kHz) electric discharge, which generates non-thermal plasma in water solution of sodium chloride. Mainly current-voltage and Lissajous charts are discussed in the first part of this thesis. These charts describe different discharge phases: electrolysis, bubble formation, discharge breakdown and discharge regular operation in a pin-hole of a dielectric barrier. Influence of frequency, electrolyte conductivity, thickness of the diaphragm (or length of the capillary) and pin-hole diameter on discharge breakdown and bubble generation was studied, too. Measurements were realized in a polycarbonate reactor with total volume of 110 ml, which was divided by a changeable polyacetal insulating wall. This wall divided the reactor into two approximately equal spaces with one stainless steel planar electrode in each part. The Shapal-MTM ceramic discs (thickness of 0.3–1.5 mm and diameter of the central pin-hole of 0.3-0.9 mm) were mounted in the centre of the insulating wall. Initial conductivity of sodium chloride solution was chosen within the interval of 100900 S/cm. The second part of my thesis compares an influence of the direct-current (DC) and high frequency (HF) power sources on physical solution properties (conductivity, pH and temperature) and generation of hydrogen peroxide. A plasma reactor with total volume of 4 l and with mixing set up was divided into two equal spaces with one planar platinum electrode in each part. Diaphragm with thickness of 0.6 mm and pin-hole diameter of 0.6 mm was installed in the middle of the separating wall. Experiment was held at discharge operation of 45 W for 40 minutes with both power sources. Detection of hydrogen peroxide was realised by using a titanium reagent forming a yellow complex, which was analysed by absorption spectroscopy. If HF discharge power is plotted as a function of applied frequency, exponential decrease of frequency with increasing power can be observed. Higher breakdown voltage is necessary for thicker dielectric barriers, on the other hand for bigger diameter of the pin-hole lower breakdown voltage and higher power is needed in DC as well as in HF regime. Breakdown voltage is decreased by the increasing conductivity in both regimes; due to more charge carriers in the higher conductivity lower breakdown voltage is needed. However frequency in HF regime and DC discharge power increases. HF discharge power is decreased by the increasing conductivity. Solution conductivity and temperature are increased by initial conductivity value in both discharge regimes. Solution pH drops to acidic conditions when HF or DC positive regime is applied due to the generation of reactive species and electrolysis (in DC regime). However solution becomes alkaline when DC negative regime is applied. Concentration of hydrogen peroxide is produced linearly when HF or DC negative regime is applied and it depends on initial solution conductivity.
Diaphragm discharge in organic dye solutions with focus on electrolytic decomposition
Davidová, Jaroslava ; Brablec, Antonín (referee) ; Kozáková, Zdenka (advisor)
This Diploma thesis is focused on physical and chemical effects which contribute to the decomposition of organic dyes by diaphragm discharge generated in water solutions. Due to the application of DC high voltage source in continuous regime, there is an effect of electrolysis contributing to the dye decomposition by diaphragm discharge. The aim of this work was to find out when the electrolysis is running (or when is the moment of discharge breakdown) and which factors influence the breakdown. The other goal was decomposition of selected textile and food organic dyes by electrolysis itself. In the theoretical part, theory about creation of electrical discharges in aqueous solutions is noted and various types of underwater discharges are described. Background researches about underwater electrical discharges used in the world are mentioned as well as the use of diaphragm discharges and various ways how to remove organic dyes from wastewater. Finally, theories of electrolysis, UV-VIS spectroscopy and basis of other analytical methods useful for detection of organic molecules are described. Experimental part is oriented to experiment procedure which was carried out in a reactor with separated electrode areas. Separation was made by dielectric diaphragm with a pinhole in the centre. Its initial diameter was 0.4 mm. Used chemicals and course of experiments are described in this part, too. First, the breakdown moment in the reactor was investigated (i. e. determination, when only electrolysis was operating) by formation of hydrogen peroxide and measurement of dynamic (time resolved) electrical characteristics. Next, decomposition of selected dyes by electrolysis was carried out. As the decomposition was related to decolorization of the solution, UV-VIS spectroscopy in the range of 350–700 nm was used for determination of dye concentration. Next part focused on results presents various factors which had an effect on breakdown of diaphragm discharge. These factors are kind of used electrolyte, initial conductivity of solution, kind of dye, temperature of solution and type of reactor (or solution volume). From the result, the most important factor is initial solution conductivity. After the determination of the breakdown moment, the electrolysis of organic dyes was performed. The applied current was 10 mA, initial conductivity was 500 µS/cm and used electrolyte was NaCl. Moreover comparison of dye decomposition in dependence on the different applied power was realized. From this comparison one can assume, there is no significant contribution of electrolysis (the efficiency is approximately 15 %) to the diaphragm discharge in aqueous solution.

Interested in being notified about new results for this query?
Subscribe to the RSS feed.